Use este identificador para citar ou linkar para este item: https://repositorio.ufu.br/handle/123456789/50430
ORCID:  http://orcid.org/0000-0002-3269-0347
Tipo do documento: Tese
Tipo de acesso: Acesso Embargado
Término do embargo: 2028-05-29
Título: Desenvolvimento e validação de ergômetro específico para avaliação do desempenho anaeróbio em usuários de cadeira de rodas
Título(s) alternativo(s): Development and Validation of a Specific Ergometer for Assessing Anaerobic Performance in Wheelchair Users
Autor(es): Arruda Neto, José Eduardo
Primeiro orientador: Araújo, Cleudmar Amaral de
Primeiro coorientador: Souza, Márcio Peres de
Primeiro membro da banca: Fidale, Thiago Montes
Segundo membro da banca: Souza, Fernando Lourenço de
Terceiro membro da banca: Oliveira, Érick Prado de
Quarto membro da banca: Cardoso, Lucas de Souza
Resumo: A avaliação da potência anaeróbia em usuários de cadeira de rodas manuais (UCRM) é fundamental para a prescrição do treinamento no esporte paralímpico. Entretanto, a escassez de ergômetros específicos e validados para essa população limita a acurácia das avaliações, uma vez que os cicloergômetros de braço (CEB), embora amplamente utilizados, não reproduzem fielmente o gesto motor da propulsão manual. Assim, o objetivo deste estudo foi validar um protótipo de ergômetro para UCRM (ERG01), comparando as respostas fisiológicas, neuromusculares, metabólicas e o desempenho mecânico obtidos durante o Teste Anaeróbio de Wingate de 30 segundos (TAnW_30) com aqueles observados em um CEB. Trata-se de um estudo cruzado realizado com nove atletas de basquete e rugby em cadeira de rodas. Os participantes executaram o TAnW_30 no ERG01 e no CEB em ordem randomizada e contrabalanceada. Foram avaliados o desempenho mecânico (potência pico, média e mínima, além do índice de fadiga), a atividade eletromiográfica (EMG) de oito músculos dos membros superiores, a frequência cardíaca (FC), a pressão arterial (PA), o duplo produto (DP), a concentração de lactato sanguíneo ([Lac]) e a percepção subjetiva de esforço (PSE). As potências pico e média, bem como o índice de fadiga, foram significativamente maiores no CEB (p < 0,05). A análise eletromiográfica revelou maior ativação do bíceps braquial e dos grupos flexores e extensores do carpo no CEB (p < 0,05), enquanto o peitoral maior e o deltoide apresentaram maior ativação no ERG01 (p < 0,05). Não foram observadas diferenças significativas entre os equipamentos para FC, PA, DP, [Lac] e PSE (p > 0,05). Conclui-se que o ERG01 apresentou validade concorrente parcial. Embora os parâmetros absolutos de desempenho mecânico tenham sido inferiores aos observados no CEB, possivelmente em razão da maior especificidade e complexidade biomecânica do gesto de propulsão, o equipamento foi capaz de induzir respostas cardiovasculares, metabólicas e perceptivas equivalentes às de um esforço máximo. Dessa forma, o ERG01 configura-se como um instrumento ecologicamente válido e fisiologicamente seguro para a avaliação da potência anaeróbia em atletas usuários de cadeira de rodas.
Abstract: Assessing anaerobic power in manual wheelchair users (MWUs) is essential for prescribing training in Paralympic sports. However, the scarcity of specific and validated ergometers for this population limits assessment accuracy, since arm crank ergometers (ACEs), although widely used, do not faithfully replicate the motor pattern of manual propulsion. Therefore, the aim of this study was to validate an ergometer prototype for MWUs (ERG01), comparing the physiological, neuromuscular, and metabolic responses and the mechanical performance obtained during the 30-second Wingate Anaerobic Test (WAnT_30) with those observed on an ACE. This was a crossover study conducted with nine wheelchair basketball and rugby athletes. Participants performed the WAnT_30 on the ERG01 and the ACE in a randomized and counterbalanced order. Mechanical performance (peak, mean, and minimum power, as well as fatigue index), electromyographic (EMG) activity of eight upper-limb muscles, heart rate (HR), blood pressure (BP), rate–pressure product (RPP), blood lactate concentration ([Lac]), and rating of perceived exertion (RPE) were evaluated. Peak and mean power, as well as the fatigue index, were significantly higher on the ACE (p < 0.05). Electromyographic analysis revealed greater activation of the biceps brachii and the wrist flexor and extensor groups on the ACE (p < 0.05), whereas the pectoralis major and deltoid showed greater activation on the ERG01 (p < 0.05). No significant differences were observed between the devices for HR, BP, RPP, [Lac], or RPE (p > 0.05). It is concluded that the ERG01 demonstrated partial concurrent validity. Although absolute mechanical performance parameters were lower than those observed on the ACE, possibly due to the greater specificity and biomechanical complexity of the propulsion movement, the device was able to elicit cardiovascular, metabolic, and perceptual responses equivalent to those of maximal effort. Thus, the ERG01 constitutes an ecologically valid and physiologically safe instrument for assessing anaerobic power in wheelchair athletes.
Palavras-chave: Ciências médicas
Cadeira de Rodas
Teste de Wingate
Esporte Paralímpico
Avaliação Funcional
Ergômetro
Ergometer
Wheelchair
Wingate Test
Paralympic Sport
Functional Assessment
Área(s) do CNPq: CNPQ::CIENCIAS DA SAUDE::EDUCACAO FISICA
Assunto: Ciências médicas
Cadeiras de rodas - Deficiência física
Fisiopatologia
Esportes para pessoas com deficiência
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Ciências da Saúde
Referência: ARRUDA NETO, José Eduardo. Desenvolvimento e validação de ergômetro específico para avaliação do desempenho anaeróbio em usuários de cadeira de rodas. 2026. 238 f. Tese (Doutorado em Ciências da Saúde) - Universidade Federal de Uberlândia, Uberlândia, 2026. DOI http://doi.org/10.14393/ufu.te.2026.11019.
Identificador do documento: http://doi.org/10.14393/ufu.te.2026.11019
URI: https://repositorio.ufu.br/handle/123456789/50430
Data de defesa: 29-Mai-2026
Objetivos de Desenvolvimento Sustentável (ODS): ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades.
Aparece nas coleções:TESE - Ciências da Saúde

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Avaliacaoprototipoergometro (1).pdf
  Até 2028-05-29
8.93 MBAdobe PDFVisualizar/Abrir    Solictar uma cópia


Este item está licenciada sob uma Licença Creative Commons Creative Commons