Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/45080
ORCID:  http://orcid.org/0000-0002-5169-6605
Tipo de documento: Dissertação
Tipo de acceso: Acesso Aberto
Título: Análise de dose de radiação materno/fetal e ocupacional em cardiologia intervencionista: uso de simulação Monte Carlo e simulador antropomórfico computacional
Título (s) alternativo (s): Analysis of maternal/fetal and occupational radiation dose in interventional cardiology: use of Monte Carlo simulation and computational anthropomorphic phantom
Autor: Souza, Daniela Santana de
Primer orientador: Santos, William de Souza
Primer miembro de la banca: Belinato, Walmir
Segundo miembro de la banca: Neves, Lucio Pereira
Resumen: Este estudo utilizou simulações Monte Carlo para avaliar a exposição à radiação de uma paciente gestante (24a semana de gestação) e de um médico intervencionista durante um procedimento de angiografia coronária em cardiologia intervencionista. A paciente foi representada pelo simulador antropomórfico computacional Katja, enquanto o médico foi modelado com o simulador antropomórfico computacional de referência da ICRP 110. Todo o modelo computacional de exposição foi desenvolvido utilizando o código de transporte de radiação MCNPX 2.7.0, permitindo uma estimativa detalhada das doses absorvidas nos diferentes tecidos e órgãos. Os resultados demonstraram que a utilização de equipamentos de proteção individual (EPIs), como protetor craniano, óculos plumbíferos e protetor de tireoide, reduz significativamente a dose recebida pelo médico, especialmente nas lentes dos olhos e na tireoide, com reduções que atingem até 50% em algumas projeções. Além disso, a cortina de chumbo mostrou-se eficaz na atenuação da radiação dispersa, com reduções variáveis na dose ocupacional, chegando a 73% em certas configurações. A simulação também permitiu estimar a dose fetal, auxiliando na avaliação dos riscos para a gestante e contribuindo para o desenvolvimento de estratégias de otimização da proteção radiológica em procedimentos cardiológicos intervencionistas.
Abstract: This study used Monte Carlo simulations to assess the radiation exposure of a pregnant patient (24th week of gestation) and an interventional physician during a coronary angiography procedure in interventional cardiology. The patient was represented by the computational anthropomorphic phantom Katja, while the physician was modeled using the ICRP 110 reference computational anthropomorphic phantom. The entire computational exposure model was developed using the MCNPX 2.7.0 radiation transport code, enabling a detailed estimation of the doses absorbed in different tissues and organs. The results demonstrated that the use of personal protective equipment (PPE), such as a cranial shield, leaded glasses, and a thyroid protector, significantly reduces the physician’s received dose, particularly in the lenses of the eyes and the thyroid, with reductions of up to 50% in some projections. Additionally, the lead curtain proved effective in attenuating scattered radiation, with variable reductions in occupational dose, reaching up to 73% in certain configurations. The simulation also allowed for the estimation of the fetal dose, aiding in the assessment of risks to the pregnant patient and contributing to the development of optimization strategies for radiological protection in interventional cardiology procedures.
Palabras clave: Cardiologia intervencionista
Simulação Monte Carlo
Simulador antropomórfico computacional
Paciente gestante
Interventional cardiology
Monte Carlo simulation
Computational anthropomorphic phantom
Pregnant patient
Área (s) del CNPq: CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA
Tema: Engenharia biomédica
Cardiologia pediátrica
Efeito da radiação
Monte Carlo, Método de
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Engenharia Biomédica
Cita: SOUZA, Daniela Santana de. Análise de dose de radiação materno/fetal e ocupacional em cardiologia intervencionista: uso de simulação Monte Carlo e simulador antropomórfico computacional. 2025. 55 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Federal de Uberlândia, Uberlândia, 2025. DOI http://doi.org/10.14393/ufu.di.2025.148.
Identificador del documento: http://doi.org/10.14393/ufu.di.2025.148
URI: https://repositorio.ufu.br/handle/123456789/45080
Fecha de defensa: 26-feb-2025
Objetivos de Desarrollo Sostenible (ODS): ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades.
Aparece en las colecciones:DISSERTAÇÃO - Engenharia Biomédica

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
AnaliseDoseRadiacao.pdfDissertação3.04 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.