Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/49655
Document type: Dissertação
Access type: Acesso Embargado
Embargo Date: 2028-07-06
Title: Veracidade, usabilidade e relação custo-performance de 15 escâneres intraorais na aquisição de imagens de prótese sobre implantes: estudo comparativo in-vitro de tecnologias da próxima geração
Alternate title (s): trueness, usability, and cost-performance of 15 intraoral scanners in implant dentistry: a comparative in vitro study of next-generation technologies
Author: Dib, Carolina Neves Tannous
First Advisor: Zancopé, Karla
First member of the Committee: Soares, Carlos José
Second member of the Committee: Gonçalves, Thais Marques Simek Vega
Summary: Este estudo comparativo in vitro teve como objetivo fazer uma análise integrada de 15 escâneres intraorais (IOSs), relacionando performance em próteses implantadas com viabilidade operacional e econômica, auxiliando na tomada de decisão para adesão do fluxo digital na implantodontia. Um manequim parcialmente edêntulo foi preparado com dois implantes Helix GM e escaneado por escâner de bancada inEosX5 e 15 IOSs (Primescan, Omnicam, Virtuo Vivo, Sirios, Sirios x3, Medit i600, Medit i900, Trios 3, Trios 5, Aoralscan 3, CS 3600, CS3800W, iTero Element 5D, iTero Lumina e Eagle Scan) (n=10). A veracidade foi avaliada com sobreposição de malhas 3D em relação à referência; a análise operacional por meio do System Usability Scale (SUS) e o custo-performance a partir de tabela contendo custo e características técnicas. Os dados de acurácia foram analisados com teste Kruskal-Wallis e post-hoc (α=0.05). Houve diferença significativa de acurácia entre os IOSs (p<0.001). Todos apresentaram performance satisfatória, com exceção do iTero Element (101µm [22.3-188µm]) e Virtuo Vivo (92.9µm [56.8-152 µm]). O Trios 5 apresentou menor desvio e menor distância interquartis (32.5µm [30.5-38.4]), enquanto que o Sirios x3 apresentou diferença estatística entre variados IOSs. A média de scores SUS foi de 90 (±12). A análise de custo-performance demonstrou variabilidade entre os IOSs, sem haver relação proporcional clara entre custo, tipo de aparelho e desempenho. Apesar das diferenças de desempenho na captura de TEIs, a maioria dos IOSs apresentou acurácia satisfatória para próteses implantadas, com destaque para o Trios 5, que mostrou alta acurácia e usabilidade. Esses achados destacam que a seleção do IOS deve se basear em uma análise integrada de performance, usabilidade e custo-performance.
Abstract: This in vitro comparative study aimed to provide an integrated evaluation of 15 intraoral scanners (IOSs), correlating their performance in implant-supported prostheses with operational feasibility and cost-performance to support decision-making in digital implant dentistry. A partially edentulous mandibular model was prepared with two Helix GM implants and scanned using a laboratory scanner inEos X5 as the reference standard and 15 IOSs (Primescan, Omnicam, Virtuo Vivo, Sirios, Sirios x3, Medit i600, Medit i900, Trios 3, Trios 5, Aoralscan 3, CS 3600, CS3800W, iTero Element 5D, iTero Lumina and Eagle Scan) (n=10). Trueness was evaluated by 3D mesh superimposition over the reference model. Usability was evaluated using the System Usability Scale (SUS) and cost-performance was analyzed based on cos and technical characteristics. Accuracy data was statistically analyzed with Kruskal-Wallis and post-hoc tests (α=0.05). Significant differences in accuracy were observed among IOSs (p<0.001). All IOSs showed clinically acceptable performance except iTero Element (101µm [22.3-188µm]) and Virtuo Vivo (92.9 µm [56.8-152 µm]). Trios 5 showed the lowest deviation and interquartile range (32.5µm [30.5–38.4µm]), while Sirios x3 exhibited significant statistically difference among several IOSs. The mean SUS score was 90 (±12). Cost-performance analysis revealed variability among IOSs, with no clear proportional relationship between cost, IOS type, and performance. Despite differences in performance during scanbody acquisition, most IOSs demonstrated clinically acceptable accuracy for implant-supported prostheses, with Trios 5 showing the lowest median RMS value. These findings highlight that IOS selection should be based on an integrated assessment of performance, usability, and cost-performance.
Keywords: Escaneamento 3D
Prótese dentária
Implante dentário
Custo-efetividade
Imaging
Dental prostheses
Dental implants
Cost-effectiveness analysis
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::CLINICA ODONTOLOGICA
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::MATERIAIS ODONTOLOGICOS
Subject: Odontologia
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Odontologia
Quote: DIB, Carolina Neves Tannous. Veracidade, usabilidade e relação custo-performance de 15 escâneres intraorais na aquisição de imagens de prótese sobre implantes: estudo comparativo in-vitro de tecnologias da próxima geração. 2026. 42 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2026. DOI http://doi.org/10.14393/ufu.di.2026.493.
Document identifier: http://doi.org/10.14393/ufu.di.2026.493
URI: https://repositorio.ufu.br/handle/123456789/49655
Date of defense: 6-Jul-2026
Sustainable Development Goals SDGs: ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades.
ODS::ODS 9. Indústria, Inovação e infraestrutura - Construir infraestrutura resiliente, promover a industrialização inclusiva e sustentável, e fomentar a inovação.
Appears in Collections:DISSERTAÇÃO - Odontologia

Files in This Item:
File Description SizeFormat 
VeracidadeUsabilidadeRelação.pdf
  Until 2028-07-06
2.28 MBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons