Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/49122
ORCID:  http://orcid.org/0009-0002-3634-4705
Tipo de documento: Dissertação
Tipo de acceso: Acesso Aberto
Título: Revisão e proposta de estratégia de controle de movimento para um gerador linear a ímã permanente movido a pistão livre para regime permanente
Título (s) alternativo (s): Review and proposal of a motion control strategy for a free-piston-driven permanent-magnet linear generator under steady-state operation
Autor: Scotti, Thaís Matos
Primer orientador: Santos, Marcelo Braga dos
Primer coorientador: Gomes, Luciano Coutinho
Primer miembro de la banca: Santos Neto, Pedro José dos
Segundo miembro de la banca: Steffen Junior, Valder
Resumen: Este trabalho investiga o controle do movimento em um gerador linear de pistão livre (Free- Piston Linear Generator - FPLG), com o objetivo de regular a extração eletromagnética de energia de modo a garantir operação estável dentro dos limites mecânicos e desempenho adequado na geração de potência elétrica. Para isso, o sistema é modelado como um oscilador massa–mola excitado pela combustão, no qual a força eletromagnética é representada por um amortecimento equivalente proporcional à velocidade do pistão, considerando-se uma arquitetura elétrica composta por retificação trifásica passiva seguida de conversor CC–CC do tipo boost. Três estratégias de controle são desenvolvidas e avaliadas sob as mesmas condições de modelagem e excitação: (i) controle proporcional–integral com detecção de pico do deslocamento, (ii) controle baseado na energia mecânica do ciclo e (iii) controle preditivo não linear (Nonlinear Model Predictive Control - NMPC), sendo a comparação realizada em termos do curso do pistão, da estabilidade do regime oscilatório, do balanço energético e da potência elétrica entregue à carga. Os resultados mostram que o controle PI com detecção de pico apresenta bom desempenho em regime, porém com maior latência frente a perturbações; o controle baseado na energia mecânica do ciclo permite regular a extração de energia ao longo da oscilação, contribuindo para a contenção do deslocamento e para a robustez frente a variações da combustão; e o NMPC permite tratar restrições operacionais de forma explícita, ao custo de maior modulação do comando e menor uniformidade da potência elétrica na arquitetura considerada. Conclui-se que as estratégias apresentam compromissos distintos entre estabilidade mecânica, robustez e aproveitamento energético, fornecendo uma base comparativa para o projeto de controladores aplicados a FPLGs.
Abstract: This work investigates motion control in a free-piston linear generator (FPLG), with the objective of regulating electromagnetic energy extraction in order to ensure stable operation within mechanical limits and adequate performance in electrical power generation. For this purpose, the system is modeled as a combustion-excited mass–spring oscillator in which the electromagnetic force is represented as an equivalent damping proportional to the piston velocity, considering an electrical architecture composed of passive three-phase rectification followed by a DC–DC boost converter. Three control strategies are developed and evaluated under the same modeling and excitation conditions: (i) proportional–integral control with peak displacement detection, (ii) control based on the mechanical energy of the cycle, and (iii) nonlinear model predictive control (NMPC). The comparison is carried out in terms of piston stroke, oscillatory regime stability, energy balance, and DC power delivered to the load. The results show that PI control with peak detection achieves good steady-state performance, but with higher latency under disturbances; the mechanical-energy-based control regulates energy extraction throughout the oscillation cycle, contributing to stroke containment and robustness to combustion variations; and NMPC enables explicit handling of operational constraints, at the cost of increased command modulation and lower uniformity of the electrical power in the considered architecture. It is concluded that the strategies present different trade-offs between mechanical stability, robustness, and energy utilization, providing a comparative basis for controller design in FPLGs.
Palabras clave: Gerador Linear de Pistão Livre
Controle de deslocamento
Amortecimento Eletromagnético
Controle Preditivo Não Linear
Controle Baseado em Energia
Retificação Passiva
Área (s) del CNPq: CNPQ::ENGENHARIAS::ENGENHARIA MECANICA::MECANICA DOS SOLIDOS
Tema: Engenharia mecânica
Correntes elétricas - Potencia
Força (Mecânica)
Osciladores elétricos
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Engenharia Mecânica
Cita: SCOTTI, Thaís Matos. Revisão e proposta de estratégia de controle de movimento para um gerador linear a ímã permanente movido a pistão livre para regime permanente. 2026. 129 p. Dissertação (Mestrado em Engenharia Mecânica) — Universidade Federal de Uberlândia, Uberlândia, 2026. DOI: 10.14393/ufu.di.2026.502.
Identificador del documento: http://doi.org/10.14393/ufu.di.2026.502
URI: https://repositorio.ufu.br/handle/123456789/49122
Fecha de defensa: 16-jun-2026
Objetivos de Desarrollo Sostenible (ODS): ODS::ODS 9. Indústria, Inovação e infraestrutura - Construir infraestrutura resiliente, promover a industrialização inclusiva e sustentável, e fomentar a inovação.
Aparece en las colecciones:DISSERTAÇÃO - Engenharia Mecânica

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
RevisãoPropostaEstratégia.pdf2.77 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.