Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufu.br/handle/123456789/47500| Tipo de documento: | Tese |
| Tipo de acceso: | Acesso Aberto |
| Título: | Dopplerfluxometria da Artéria Oftálmica em Gestantes: Concordância Interobservador frente à Apneia Induzida |
| Título (s) alternativo (s): | Dopplerfluxometria da Artéria Oftálmica em Gestantes |
| Autor: | Guedes Junior, Cairo Antonio |
| Primer orientador: | Diniz, Angélica Lemos Debs |
| Primer miembro de la banca: | Araújo Júnior, Edward |
| Segundo miembro de la banca: | Sá, Renato Augusto Moreira de |
| Tercer miembro de la banca: | Rodrigues, Márcia Aires |
| Cuarto miembro de la banca: | Prado Filho, Francisco Cyro Reis de Campos |
| Quinto miembro de la banca: | Diniz, Angélica Lemos Debs |
| Resumen: | Objetivo: Avaliar a concordância interobservador entre dois examinadores da Dopplefluxometria da artéria oftálmica (DAO) em gestantes saudáveis em três momentos distintos: antes, durante e após apneia induzida. Métodos: Estudo clínico prospectivo longitudinal envolvendo 30 gestantes saudáveis. A avaliação da DAO foi conduzida por dois examinadores experientes, sem conhecimento dos resultados encontrados entre eles, em um único olho, sendo realizada em três tempos: Tempo 1 (antes da apneia), Tempo 2 (final da apneia induzida) e Tempo 3 (três minutos após o retorno à respiração normal). Foram mensurados os seguintes parâmetros: primeiro pico de velocidade sistólica (P1), segundo pico de velocidade sistólica (P2), razão de pico (PR), índice de pulsatilidade (IP), índice de resistência (IR) e velocidade diastólica final (VDF). Para análise da reprodutibilidade interobservador, utilizou-se o método de Bland-Altman e o coeficiente de correlação intraclasse. Resultado: Os achados identificaram excelente concordância interobservador para PR, IR e IP em todos os tempos analisados. Para VDF, P1 e P2, observou-se boa concordância, com pequenas variações nos limites de concordância nos três tempos. Conclusões: Os índices DAO apresentaram concordância interobservador para todos os índices analisados em gestantes saudáveis durante três tempos: no repouso, final da apneia induzida e após três minutos de pausa da apneia. Observou-se excelente concordância para os parâmetros PR, IP e IR em todos os tempos (T1, T2 e T3), sugerindo que podem ser utilizados com segurança na prática clínica. Os resultados deste estudo indicam que a apneia induzida é factível e poderá ser usada na análise da AO durante a gestação. |
| Abstract: | Objective: To evaluate the interobserver agreement between two examiners of Dopplerfluxometry of the ophthalmic artery (DOA) in healthy pregnant women at three different time points: before, during, and after induced apnea. Methods: Prospective longitudinal clinical study involving 30 healthy pregnant women. The DAO assessment was conducted by two experienced examiners, blinded to each other's results, in a single eye, and performed at three time points: Time 1 (before apnea), Time 2 (end of induced apnea), and Time 3 (three minutes after return to normal breathing). The following parameters were measured: first peak systolic velocity (P1), second peak systolic velocity (P2), peak ratio (PR), pulsatility index (PI), resistance index (RI), and end-diastolic velocity (EDV). The Bland-Altman method and the intraclass correlation coefficient were used to analyze interobserver reproducibility. Results: The findings identified excellent interobserver agreement for PR, IR, and PI at all time points analyzed. Good agreement was observed for VDF, P1, and P2, with small variations in the limits of agreement at the three time points. Conclusions: The DOA indices showed interobserver agreement for all indices analyzed in healthy pregnant women during three time points: at rest, at the end of induced apnea, and after a three-minute pause. Excellent agreement was observed for the PR, IP, and IR parameters at all time points (T1, T2, and T3), suggesting that they can be used safely in clinical practice. The results of this study indicate that induced apnea is feasible and can be used in the analysis of AO during pregnancy. |
| Palabras clave: | Ultrassonografia Doppler Artéria Oftálmica Gestação Reprodutibilidade de Resultados Apneia Doppler ultrasonography Ophthalmic artery Pregnancy Reproducibility of results Apnea |
| Área (s) del CNPq: | CNPQ::CIENCIAS DA SAUDE |
| Tema: | Ciências médicas |
| Idioma: | por |
| País: | Brasil |
| Editora: | Universidade Federal de Uberlândia |
| Programa: | Programa de Pós-graduação em Ciências da Saúde |
| Cita: | GUEDES JUNIOR, Cairo Antonio. Dopplerfluxometria da Artéria Oftálmica em Gestantes: Concordância Interobservador frente à Apneia Induzida. 2025. 75 f. Tese (Doutorado em Ciências da Saúde) - Universidade Federal de Uberlândia, Uberlândia, 2025. DOI http://doi.org/10.14393/ufu.te.2025.619. |
| Identificador del documento: | http://doi.org/10.14393/ufu.te.2025.619 |
| URI: | https://repositorio.ufu.br/handle/123456789/47500 |
| Fecha de defensa: | 10-oct-2025 |
| Objetivos de Desarrollo Sostenible (ODS): | ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades. |
| Aparece en las colecciones: | TESE - Ciências da Saúde |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| DopplerfluxometriadaArtéria.pdf | Tese | 4.46 MB | Adobe PDF | ![]() Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.
