Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/46658
ORCID:  http://orcid.org/0009-0009-8909-312X
Document type: Trabalho de Conclusão de Curso
Access type: Acesso Embargado
Embargo Date: 2027-08-14
Title: Avaliação da adaptação marginal e interna de coroas cad/cam de dissilicato de lítio fabricadas por diferentes unidades de fresagem
Author: Junqueira, Vinicius Sandrin
First Advisor: Prudente, Marcel Santana
First member of the Committee: Raposo, Luis Henrique Araujo
Second member of the Committee: Neves, Flávio Domingues das
Summary: Objetivo: Este estudo teve como objetivo comparar a adaptação marginal e interna de coroas de dissilicato de lítio fresadas por dois sistemas distintos de CAD/CAM: MCXL (MX) e Primemill (PM). Um objetivo secundário foi caracterizar e comparar as características macroestruturais e microestruturais das brocas diamantadas utilizadas por cada sistema, considerando uma potencial influência na acurácia da confecção das restaurações. Métodologia: Para isso, um modelo padronizado simulando uma preparação total para coroa foi escaneado dez vezes (n=10) utilizando o escâner intraoral Primescan 1.0. Desenhos padronizados de coroas foram gerados no software CEREC 5.0 e fresados por ambas as unidades. A adaptação foi avaliada por meio da técnica de varredura tripla com alinhamento dos arquivos STL no software Exocad. O ajuste interno foi medido em cinco pontos de referência, enquanto a adaptação marginal foi avaliada nas dimensões vertical (MG) e horizontal (MH). A topografia superficial das brocas foi analisada por microscopia eletrônica de varredura (MEV). A análise estatística incluiu testes de homogeneidade e o teste post hoc de Tukey. Resultados: O grupo PM demonstrou adaptação significativamente superior em todas as regiões avaliadas, exceto na parede axial (AW), onde não foi observada diferença estatística. Os valores de adaptação para PM e MX, respectivamente, foram: FL [149,5(24,9)–267,4(22,0)] (p<0,0001); AW [114,6(48,9)–127,6(18,2)] (p<0,0001); BC [126,5(19,6)–104,6(13,7)] (p=0,0098); OCF [80,5(26,2)–172,4(17,0)] (p<0,0001); LC [94,1(31,5)–134,6(15,4)] (p=0,0018); MG [2,9(6,2)–16,2(13,07)] (p=0,0002); MH [49,3(43,6)–84,7(46,3)] (p=0,0174). A análise por MEV revelou maior densidade de partículas de diamante nas brocas MX, enquanto as brocas PM apresentaram maior comprimento e diâmetro totais. Conclusão: Portanto, o sistema Primemill demonstrou desempenho superior em termos de adaptação, e as diferentes geometrias das brocas podem influenciar significativamente a precisão na fabricação de coroas.
Abstract: Objetive: This study aimed to compare the marginal and internal adaptation of lithium disilicate crowns milled using two distinct CAD/CAM systems: MCXL (MX) and Primemill (PM). A secondary objective was to characterize and compare the macrostructural and microstructural features of the diamond burs employed by each system, considering their potential influence on restoration accuracy. Methods: A standardized die simulating a full-crown preparation was scanned ten times (n=10) using the Primescan 1.0 intraoral scanner. Identical crown designs were generated in CEREC 5.0 software and milled using both units. Adaptation was assessed through the triple-scan technique with STL file alignment in Exocad software. Internal fit was measured at five reference points, while marginal adaptation was evaluated in both vertical (MG) and horizontal (MH) dimensions. The surface topography of the burs was analyzed via scanning electron microscopy (SEM). Statistical analysis included homogeneity testing and Tukey’s post hoc test. Results: The PM group demonstrated significantly improved adaptation in all evaluated regions, with the exception of the axial wall (AW), where no statistical difference was observed. Adaptation values for PM and MX, respectively, were: FL [149.5(24.9)–267.4(22.0)] (p<0.0001); AW [114.6(48.9)–127.6(18.2)] (p<0.0001); BC [126.5(19.6)–104.6(13.7)] (p=0.0098); OCF [80.5(26.2)–172.4(17.0)] (p<0.0001); LC [94.1(31.5)–134.6(15.4)] (p=0.0018); MG [2.9(6.2)–16.2(13.07)] (p=0.0002); MH [49.3(43.6)–84.7(46.3)] (p=0.0174). SEM analysis revealed a higher density of diamond particles on MX burs, whereas PM burs exhibited greater overall length and diameter. Conclusion: Primemill demonstrated superior adaptation performance, and distinct bur geometries may significantly influence the precision of crown fabrication.
Keywords: Cerâmica
Coroas
Adaptação Marginal Dentária
CAD/CAM
Ceramics
Crowns
Marginal fit
Internal fit
Digital dentistry
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Quote: JUNQUEIRA, Vinicius Sandrin. Avaliação da adaptação marginal e interna de coroas cad/cam de dissilicato de lítio fabricadas por diferentes unidades de fresagem. 2025. 61f. Trabalho de Conclusão de Curso (Graduação em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2025.
URI: https://repositorio.ufu.br/handle/123456789/46658
Date of defense: 14-Aug-2025
Appears in Collections:TCC - Odontologia

Files in This Item:
File Description SizeFormat 
AvaliacaodaAdaptacaoMarginal.pdf
  Until 2027-08-14
TCC = Trabalho de Conclusão de Curso14.58 MBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons