Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufu.br/handle/123456789/45316| ORCID: | http://orcid.org/0000-0002-5342-3539 |
| Tipo de documento: | Trabalho de Conclusão de Curso |
| Tipo de acceso: | Acesso Aberto |
| Título: | Investigating Microarchitectural Characteristics of Woven Bone Exposed to Ionizing Radiation: Comparative Analysis of Two Segmentation Methods and Their Impact on Trabecular Measurements in an Animal Study |
| Autor: | Bites, Clara de Oliveira Barbosa |
| Primer orientador: | Soares, Priscilla Barbosa Ferreira |
| Primer coorientador: | Pitorro, Tássio Edno Atanásio |
| Primer miembro de la banca: | Soares, Priscilla Barbosa Ferreira |
| Segundo miembro de la banca: | Lima, Lívia Bonjardim |
| Tercer miembro de la banca: | Henriques, João César Guimarães |
| Resumen: | The study aimed to evaluate bone formation in surgical defects exposed to ionizing radiation (IR) and to compare two image segmentation methods: manual and standardized delimitation of the region-ofinterest (ROI). Bone defects were created in the tibias of Wistar rats using a 2.3 mm trephine. After seven days, the animals were exposed to IR (30 Gy single dose). Two weeks later, the animals were euthanized, and their tibias were scanned using X-ray microtomography. ROI definition was performed by a single operator using two methods: (a) interactive segmentation, where the woven bone was manually outlined within the bone defect region, and (b) a standardized, predefined rectangular ROI. Bone volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N), bone surface (BS/BV), and fractal dimension (FD) were assessed for both segmentation methods. Significant differences were observed for BV/TV (p<0.001), Tb.N (p<0.001), and Tb.Sp (p<0.001), but not for Tb.Th (p=0.71), BS/BV (p=0.79), and FD (p=0.35). The manual method was approximately 3.5 times more timeconsuming than the predefined ROI method (446.2±49.5 vs 131.2±38.8 s, p<0.001). None of the evaluated parameters showed significant differences when the IR was considered. Within the limitations of this study, the finding indicate that IR does not interfere with the bone repair process when delivered postsurgery. While manual segmentation is more time consuming, it retrieves greater bone volume and reveals differences in trabecular structure, showing more trabeculae number and less trabeculae separation in irradiated bone. |
| Palabras clave: | Bone Fractals X-Ray Microtomography |
| Área (s) del CNPq: | CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
| Idioma: | eng |
| País: | Brasil |
| Editora: | Universidade Federal de Uberlândia |
| Cita: | BITES, Clara de Oliveira Barbosa. Investigating Microarchitectural Characteristics of Woven Bone Exposed to Ionizing Radiation: Comparative Analysis of Two Segmentation Methods and Their Impact on Trabecular Measurements in an Animal Study. 2025. 18 f. Trabalho de Conclusão de Curso (Graduação em Odontologia) – Universidade Federal de Uberlândia, Uberlândia, 2025. |
| URI: | https://repositorio.ufu.br/handle/123456789/45316 |
| Fecha de defensa: | 31-mar-2025 |
| Aparece en las colecciones: | TCC - Odontologia |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| InvestigatingMicroarchitecturalCharacteristics.pdf | TCC | 258.15 kB | Adobe PDF | ![]() Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons