Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/43517
Document type: Dissertação
Access type: Acesso Aberto
Title: Avaliação dosimétrica em Unidades de Terapia Intensiva Neonatais com a inserção de blindagem entre as incubadoras utilizando o Método Monte Carlo
Alternate title (s): Dosimetric evaluation in Neonatal Intensive Care Units with the insertion of shielding between incubators using the Monte Carlo Method
Author: Caixeta, Ana Luiza Oliveira
First Advisor: Perini, Ana Paula
First member of the Committee: Milagre, Selma Terezinha
Second member of the Committee: Caldas, Linda Viola Ehlin
Summary: Durante a hospitalização na Unidade de Terapia Intensiva Neonatal (UTIN), os neonatos são submetidos a exames de imagem para diagnosticar ou acompanhar o progresso no tratamento de doenças. O número de exposições pode variar bastante conforme a gravidade da condição e a duração da internação. A frequência dos exames de imagem durante a internação tornou-se uma preocupação frequente na área hospitalar, pois os pacientes mais jovens são mais sensíveis à radiação ionizante do que pacientes adultos, devido à maior atividade mitótica. Este estudo teve como objetivo quantificar e analisar as doses de radiação em neonatos expostos ao feixe de radiação, durante exames de tórax com equipamentos de raios X móveis na UTIN. Além disso, buscou-se avaliar as doses recebidas pelos recém-nascidos em incubadoras vizinhas aos neonatos examinados, levando em consideração a inserção de blindagens de diferentes materiais e espessuras entre as incubadoras. O estudo foi realizado computacionalmente, utilizando o código Monte Carlo N-Particle Transport (MCNP), versão 6.2, e objetos simuladores antropomórficos virtuais que representavam os neonatos analisados. Observou-se a maior redução nos valores das doses do neonato vizinho, quando foi utilizada a blindagem com espessura maior, especificamente de 0,5 mm. Entre os materiais avaliados como blindagem, observou-se uma redução das doses efetivas para o neonato vizinho de aproximadamente 99,6% para o chumbo, 99,5% para o bismuto e 98,9% para a combinação de bismuto e bário. Esses resultados demonstram que o uso de blindagem entre as incubadoras na UTIN pode reduzir significativamente as doses de radiação às quais o neonato vizinho está exposto, evitando exposições desnecessárias à radiação ionizante.
Abstract: During hospitalization in the Neonatal Intensive Care Unit (NICU), neonates undergo imaging exams to diagnose or monitor the progress of diseases. The number of exposures can vary considerably based on the severity of the patient's condition and the duration of their hospital stay. The frequency of imaging exams during hospitalization has become a frequent concern in the hospital setting, as younger patients are more sensitive to ionizing radiation than adult patients due to higher mitotic activity. This study aimed to quantify and analyze the radiation doses in neonates exposed to the radiation beam during chest exams with mobile X-ray equipment in the NICU. Additionally, the study sought to evaluate the doses received by newborns in incubators adjacent to the examined neonates, considering the insertion of shields of different materials and thicknesses between the incubators. The study was conducted computationally using the Monte Carlo N-Particle Transport (MCNP) code, version 6.2, and virtual anthropomorphic phantoms representing the analyzed neonates. The highest reduction in doses to the neighboring neonate was observed when a thicker shield, specifically 0.5 mm, was used. Among the materials evaluated as shielding, an effective dose reduction for the neighboring neonate was approximately 99.6% for lead, 99.5% for bismuth, and 98.9% for a combination of bismuth and barium. These results demonstrated that the use of shielding between incubators in the NICU can significantly reduce the radiation doses to which the neighboring neonate is exposed, thereby avoiding unnecessary exposure to ionizing radiation.
Keywords: Unidade de Terapia Intensiva Neonatal
Neonatal Intensive Care Unit
Neonato
Neonate
Monte Carlo
Monte Carlo
Blindagem
Shielding
Dosimetria
Dosimetry
Area (s) of CNPq: CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR::APLICACOES DE RADIOISOTOPOS::INSTRUMENTACAO PARA MEDIDA E CONTROLE DE RADIACAO
CNPQ::CIENCIAS EXATAS E DA TERRA::FISICA::FISICA NUCLEAR
CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA::BIOENGENHARIA::MODELAGEM DE SISTEMAS BIOLOGICOS
Subject: Engenharia biomédica
Emergências neonatais
Unidade de tratamento intensivo
Monte Carlo, Método de
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Engenharia Biomédica
Quote: CAIXETA, Ana Luiza Oliveira. Avaliação dosimétrica em Unidades de Terapia Intensiva Neonatais com a inserção de blindagem entre as incubadoras utilizando o Método Monte Carlo. 2024. 62 f. Dissertação (Mestrado em Ciências) - Universidade Federal de Uberlândia, Uberlândia, 2024. DOI http://doi.org/10.14393/ufu.di.2024.478.
Document identifier: http://doi.org/10.14393/ufu.di.2024.478
URI: https://repositorio.ufu.br/handle/123456789/43517
Date of defense: 18-Jul-2024
Sustainable Development Goals SDGs: ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades.
Appears in Collections:DISSERTAÇÃO - Engenharia Biomédica

Files in This Item:
File Description SizeFormat 
AvaliaçãodosimétricaemUnidades.pdfDissertação1.08 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.