Use este identificador para citar ou linkar para este item:
https://repositorio.ufu.br/handle/123456789/41076
Tipo do documento: | Tese |
Tipo de acesso: | Acesso Embargado Attribution-NonCommercial-NoDerivs 3.0 United States |
Término do embargo: | 2026-01-29 |
Título: | Desenvolvimento de imunossensores eletroquímicos para detecção de troponinas cardíacas. |
Título(s) alternativo(s): | Development of electrochemical immunosensors for detection of cardiac troponins |
Autor(es): | Brussasco, Jéssica Guimarães |
Primeiro orientador: | Madurro, João Marcos |
Primeiro coorientador: | Brito-Madurro, Ana Gracie |
Primeiro membro da banca: | Galdino, Fabiane Caxico de Abreu |
Segundo membro da banca: | Alves, Valéria Almeida |
Terceiro membro da banca: | Gomes, Matheus de Souza |
Quarto membro da banca: | Franco, Diego Leoni |
Resumo: | O infarto agudo do miocárdio é uma das principais causas de mortalidade nacional e mundial. Caracterizado pela necrose dos cardiomiócitos após uma situação de isquemia, seguido da liberação de biomarcadores cardíacos na corrente sanguínea, o diagnóstico precoce e eficaz desta condição clínica é de suma importância para a sobrevivência do paciente. No contexto de ferramentas diagnósticas aplicadas à detecção do infarto, os imunossensores eletroquímicos apresentam grande potencial de aplicação devido ao seu baixo custo de produção, fornecimento de respostas rápidas, facilidade operacional, especificidade, sensibilidade e possibilidade de miniaturização. Dentre os biomarcadores cárdicos utilizados para diagnóstico precoce e evolução do quadro de infarto, destacam-se as troponinas, marcadores biológicos considerados padrão-ouro, graças a sua especificidade miocárdica, rápida liberação na corrente sanguínea e elevado tempo de alteração. Assim sendo, neste trabalho dois imunossensores eletroquímicos foram desenvolvidos para a detecção de troponinas cardíacas, via imobilização por adsorção física de anticorpos anti-troponina T e anticorpos anti-troponina I na superfície de eletrodos de grafite modificados com nanomateriais derivados de grafeno, como óxido de grafeno reduzido e pontos quânticos de grafeno. |
Abstract: | Acute myocardial infarction is one of the main causes of mortality national and global. Characterized by cardiomyocyte necrosis after a situation of ischemia, followed by the release of cardiac biomarkers in the bloodstream, early and effective diagnosis of this clinical condition is of paramount importance for patient survival. In the context of diagnostic tools applied to heart attack detection, electrochemical immunosensors have great application potential due to its low production cost, provision of quick responses, operational ease, specificity, sensitivity and possibility of miniaturization. Among the cardiac biomarkers used for early diagnosis and evolution of the infarction condition, troponins stand out, markers biologicals considered the gold standard, thanks to their myocardial specificity, rapid release into the bloodstream, and a long change time. Therefore, in this work two electrochemical immunosensors were developed for the detection of cardiac troponins, via immobilization by physical adsorption of anti-troponin T antibodies and anti-troponin I antibodies on surface of graphite electrodes modified with nanomaterials derived from graphene, such as reduced graphene oxide and graphene quantum dots. |
Palavras-chave: | electrochemical immunosensor graphene quantum dots reduced graphene oxide cardiac troponin ninhydrin |
Área(s) do CNPq: | CNPQ::CIENCIAS BIOLOGICAS::BIOQUIMICA CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::FISICO-QUIMICA::ELETROQUIMICA |
Idioma: | por |
País: | Brasil |
Editora: | Universidade Federal de Uberlândia |
Programa: | Programa de Pós-graduação em Genética e Bioquímica |
Referência: | BRUSSASCO, Jéssica Guimarães. Desenvolvimento de imunossensores eletroquímicos para detecção de troponinas cardíacas. 2024. 89 f. Tese (Doutorado em genética e bioquímica) - Universidade Federal de Uberlândia, Uberlândia, 2024. DOI http://doi.org/10.14393/ufu.te.2023.414 |
Identificador do documento: | http://doi.org/10.14393/ufu.te.2023.414 |
URI: | https://repositorio.ufu.br/handle/123456789/41076 |
Data de defesa: | 22-Jan-2024 |
Objetivos de Desenvolvimento Sustentável (ODS): | ODS::ODS 4. Educação de qualidade - Assegurar a educação inclusiva, e equitativa e de qualidade, e promover oportunidades de aprendizagem ao longo da vida para todos. |
Aparece nas coleções: | TESE - Genética e Bioquímica |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
DesenvolvimentoImunossensoresEletroquímicos.pdf Até 2026-01-29 | 3.33 MB | Adobe PDF | Visualizar/Abrir Solictar uma cópia |
Este item está licenciada sob uma Licença Creative Commons