Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/29637
ORCID:  http://orcid.org/0000-0001-7875-4206
Document type: Dissertação
Access type: Acesso Aberto
Title: Avaliação ergonômica de uma órtese ativa de punho para a reabilitação da rigidez em pessoas com a doença de Parkinson
Alternate title (s): Ergonomic evaluation of an active wrist orthosis for the rehabilitation of rigidity in people with Parkinson's disease
Author: Costa, Samila Carolina
First Advisor: Andrade, Adriano de Oliveira
First member of the Committee: Pereira, Adriano Alves
Second member of the Committee: Souza, Luciane Aparecida Pascucci Sande de
Third member of the Committee: Vieira, Marcus Fraga
Summary: Introdução: A doença de Parkinson (DP) é uma doença crônica e progressiva que apresenta sinais e sintomas motores característicos. A rigidez muscular é um dos principais sinais / sintomas motores da DP e pode se manifestar em diferentes áreas do corpo, sendo mais comum nos membros superiores, o que dificulta a realização de atividades que envolvam o uso das mãos. Diante disso, a reabilitação fisioterapêutica é essencial na manutenção da funcionalidade dos membros afetados pelos sinais / sintomas motores da DP, influenciando na qualidade de vida dos indivíduos acometidos pela doença. Nesse sentido, o uso de dispositivos robóticos na reabilitação dos sinais / sintomas motores da doença de Parkinson é uma área em crescente expansão. Objetivo: Avaliar a influência de uma órtese ativa de punho (OAP) na atividade eletromiográfica dos flexores e extensores do carpo e na amplitude de movimento da articulação do punho em indivíduos com a doença de Parkinson. Métodos: A atividade muscular dos flexores e extensores do carpo foi estimada por meio de eletromiografia. Para estimar a amplitude de movimento (ADM), um modelo biomecânico da parte superior do corpo foi desenvolvido no software Visual3D e a ADM da flexão e extensão do punho foi estimada. Ambas as características, EMG e ADM, foram avaliadas com e sem o uso da órtese ativa de punho e posteriormente comparadas utilizando métodos estatísticos para verificar a influência da órtese ativa de punho na atividade muscular e amplitude de movimento durante a flexão e extensão do punho. Resultados: Os resultados mostram que o uso da órtese influencia principalmente a extensão de punho. Para o movimento de extensão do punho foi observado um aumento médio de 22% na atividade muscular do extensor radial longo do carpo e uma redução média de 9º na amplitude de movimento da extensão do punho ao usar a órtese. Conclusão: As alterações da atividade eletromiográfica e amplitude de movimento causadas pelo uso da órtese ativa de punho avaliada não são expressivas no sentido de que o dispositivo não impõe uma limitação significativa da amplitude articular em uma aplicação clínica, e o aumento da atividade muscular não dificulta ou interfere na realização das tarefas propostas no protocolo experimental, confirmando o design ergonômico da órtese e o potencial para ser utilizada na reabilitação do punho de indivíduos acometidos pela doença de Parkinson em ambiente clínico.
Abstract: Introduction: Parkinson's disease (PD) is a chronic and progressive disease that presents characteristic motor symptoms. Rigidity is one of the main motor symptoms of PD and can manifest itself in different areas of the body, being more common in the upper limbs, which makes it difficult to perform activities that involve the use of hands. Therefore, physical therapy rehabilitation is extremely important for maintaining the functionality of the limbs affected by PD motor symptoms, influencing the quality of life of individuals affected by the disease. In this sense, the use of robotic devices in the rehabilitation of motor symptoms of Parkinson's disease is an area in increasing expansion. Objective: To evaluate the ergonomics of an active wrist orthosis developed for the rehabilitation of symptoms of rigidity in individuals with PD. Methods: The muscle activity of the carpal flexors and extensors was estimated using electromyography. To estimate the motion amplitude (MA), a biomechanical model of the upper body was developed in the Visual3D software and the MA of wrist flexion and extension was estimated. Both characteristics, EMG and MA, were evaluated with and without the use of the active wrist orthosis and later compared using statistical methods to verify the influence of the active wrist orthosis. Results: The results show that the use of the orthosis mainly influences the wrist extension. For the wrist extension movement, it was observed an average increase of 22% in the muscular activity of the long radial carpal extensor and an average decrease of 9º in the motion amplitude of the wrist extension when using the orthosis. Conclusion: The changes in electromyographic activity and motion amplitude caused by the use of the evaluated active wrist orthosis are not significant in the sense that the device does not impose a significant limitation of joint amplitude in a clinical application, and the increase in muscle activity does not interfere in performing the tasks proposed in the experimental protocol, confirming the ergonomic design of the orthosis and the potential to be used in the rehabilitation of the wrist of individuals affected by Parkinson's disease in a clinical setting.
Keywords: Doença de Parkinson
Parkinson's disease
Ergonomia
Ergonomics
Órtese de punho
Wrist orthosis
Eletromiografia
Electromyography
Cinemetria
Kinematics
Reabilitação robótica
Robotic rehabilitation
Area (s) of CNPq: CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA
Subject: Aparelhos ortopédicos
Punhos
Doença de Parkinson
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Engenharia Biomédica
Quote: COSTA, Samila Carolina. Avaliação ergonômica de uma órtese ativa de punho para a reabilitação da rigidez em pessoas com a doença de Parkinson. 2020. 40 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Federal de Uberlândia, Uberlândia, 2020. DOI http://doi.org/10.14393/ufu.di.2020.500.
Document identifier: http://doi.org/10.14393/ufu.di.2020.500
URI: https://repositorio.ufu.br/handle/123456789/29637
Date of defense: 24-Jul-2020
Appears in Collections:DISSERTAÇÃO - Engenharia Biomédica

Files in This Item:
File Description SizeFormat 
AvaliacaoErgonomicaOrtese.pdf2.06 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons