Título: Dosimetria em procedimentos de radiologia intervencionista cerebral empregando simuladores antropomórficos virtuais
Título(s) alternativo(s): Dosimetry in cerebral interventional radiology procedures using virtual anthropomorphic phantoms
Autor(es): Carvalho, Eduardo Batista de
Primeiro orientador: Neves, Lucio Pereira
Segundo orientador: Santos, William de Souza
Segundo membro da banca: Kagimura, Ricardo
Terceiro membro da banca: Macedo, Túlio Augusto Alves
Quarto membro da banca: Belinato, Walmir
Resumo: Devido à disseminação da tecnologia em Radiologia Intervencionista (RI), há um crescimento diário dos procedimentos que utilizam equipamentos de uoroscopia que fazem emissão de radiação ionizante, para acompanhar a navegação de catéteres e os guia no lúmen das artérias e veias. Concomitantemente a este avanço nos tratamentos médicos, que muito bene ciam os pacientes, deve-se ter atenção aos riscos devido ao emprego das radiações ionizantes. Este risco é mais acentuado na equipe médica, que irá realizar estes procedimentos durante toda a sua vida pro ssional. Visando avaliar as doses envolvidas neste procedimentos foi realizado um estudo de dosimetria computacional das doses de radiação à que os pro ssionais e pacientes estão expostos durante um procedimento de angiogra a cerebral. Também foram comparadas as respostas de dois objetos simuladores antropomór cos virtuais diferentes (matemático e baseado em superfície mesh MASH3). A determinação das doses de radiação foi realizada empregando o software de Monte Carlo MCNP5, no Laboratório de Instrumentação e Dosimetria (LInDa) da Universidade Federal de Uberlândia. Os resultados mostraram uma grande diferença entre os objetos simuladores virtuais ADAM e MASH3. Além disso, foi possível determinar diversos coe cientes de conversão que podem ser empregados pelos pro ssionais da saúde, visando estimar as doses de radiação nos órgãos e tecidos.
Abstract: Due to the spread of technology in Interventional Radiology (IR), there is a daily growth of procedures that use uoroscopy equipment that uses emission of ionizing radiation to accompany the navigation of catheters and guides them in the lumen of the arteries and veins. Concomitantly with this advance in medical treatments that bring great bene ts to the patients, attention should be paid to the use of ionizing radiation. This risk is more accentuated in the medical team, who will perform these procedures throughout their professional life. Aiming to evaluate the doses involved in these procedures was performed a computational dosimetry study of radiation doses of radiation to which the professionals and patients are exposed during a cerebral angiography procedure. Also were compared the responses of two di erent virtual anthropomorphic simulator objects (mathematical and surface-based mesh - MASH3). The determination of radiation doses was made using the software of Monte Claro MCNP5, in the Instrumentation and Dosimetry (LInDa) of Federal University of Uberlândia. The results show a massive di erence between the objects mathematical virtual simulators and MASH3. Besides, that was possible to determine many conversion coe cients that could be used by the health professionals, aiming to estimate the radiation doses in organs and tissues.
Palavras-chave: Computacional
Simulador
Antropomórfico
Virtual
Simulação
Espectro
Radiação
Dosimetria
Órgãos
Radiologia
Angiografia
Raios
Monte Carlo
Engenharia biomédica
Computational
Simulator
Anthropomorphic
Simulation
Spectrum
Radiation
Dosimetry
Organs
Radiology
Angiography
Rays
Biomedical engineering
Área(s) do CNPq: CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Engenharia Biomédica
Referência: CARVALHO, Eduardo Batista de. Dosimetria em procedimentos de radiologia intervencionista cerebral empregando simuladores antropomórficos virtuais. 2018. 60 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Federal de Uberlândia, Uberlândia, 2019. DOI http://dx.doi.org/10.14393/ufu.di. 2019.2112
Identificador do documento: http://dx.doi.org/10.14393/ufu.di.2019.2112
URI: https://repositorio.ufu.br/handle/123456789/26238
Data de defesa: 6-Dez-2018
Aparece nas coleções:DISSERTAÇÃO - Engenharia Biomédica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DosimetriaProcedimentosRadiologia.pdfDosimetriaProcedimentoRadiologia2.15 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.