Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/24571
Tipo de documento: Tese
Tipo de acceso: Acesso Aberto
Título: Desenvolvimento de métodos eletroanalíticos simples, portáteis e de baixo custo para aplicações em análises forenses
Título (s) alternativo (s): Development of simple, portable and low-cost electroanalytical methods for applications in forensic analysis
Autor: Freitas, Jhonys Machado de
Primer orientador: Richter, Eduardo Mathias
Primer coorientador: Munoz, Rodrigo Alejandro Abarza
Primer miembro de la banca: Santos, André Luiz dos
Segundo miembro de la banca: Janegitz, Bruno Campos
Tercer miembro de la banca: Nossol, Edson
Cuarto miembro de la banca: Santos, Wallans Torres Pio dos
Resumen: Neste trabalho foi demonstrado o emprego de técnicas eletroquímicas no desenvolvimento de métodos de análise simples, de baixo custo e com características portáteis aplicados à Química Forense. As técnicas de Voltametria de Onda Quadrada (SWV, do inglês, Square Wave Voltammetry) e Amperometria de Múltiplos (MPA, do inglês, Multiple Pulse Amperometry) foram utilizadas em associação com o sistema de análise por injeção em batelada (BIA, do inglês, Batch Injection Analysis) para determinação de cocaína e “screening” de adulterantes mais comuns (cafeína, fenacetina, benzocaína, lidocaína, procaína, paracetamol e levamisol) como processo de triagem em amostras apreendidas, além de sibutramina e efedrina em suplementos alimentares e fitoterápicos. Nos métodos propostos neste trabalho, as amostras necessitam somente uma etapa de dissolução no eletrólito suporte antes da injeção na célula BIA. Uma varredura empregando SWV é então realizada na amostra injetada que é eletroquimicamente oxidada em um eletrodo de diamante dopado com boro (BDDE, do inglês, Boron-doped Diamond Electrode), resultando em um perfil voltamétrico único. Utilizando as condições experimentais otimizadas, uma faixa linear de 6 a 30 mg L- 1, foi obtida para cocaína, com um limite de detecção de 0,27 mg L-1. SWV e BDDE também foram empregados para determinação da presença de adulterantes, tais como, sibutramina e efedrina em amostras dopadas de medicamentos e/ou suplementos alimentares naturais, utilizados com intuito de emagrecimento. A detecção da sibutramina foi possível mesmo em amostras de grande complexidade como multivitamínicos. Estudos mostraram uma resposta linear de 5 a 50 mg L- 1 e limite de detecção de 0,08 mg L−1 para sibutramina. O método SWV desenvolvido para sibutramina também foi facilmente adaptável ao sistema BIA. O estudo para determinação de efedrina em suplementos alimentares, fitoterápicos e urina foi realizado empregando um sistema BIA-SWV. Uma faixa linear de 5 a 40 mg L-1 com limite de detecção de 0,13 mg L-1 foram alcançados para efedrina. O uso dos protocolos de triagem ou “screening” desenvolvidos neste trabalho se mostraram ferramentas promissoras para aplicações em análises forenses criminais e aplicadas ao esporte. Adicionalmente métodos de quantificação foram descritos para as espécies de interesse em diferentes tipos de amostra.
Abstract: In this work it was demonstrated the use of electrochemical techniques in the development of simple, low cost and portable analytical methods applied to Forensic Chemistry. The Square Wave Voltammetry (SWV) and Multiple Pulse Amperometry (MPA) techniques were used in association with the Batch Injection Analysis (BIA) system for cocaine determination and screening process of the most common adulterants (caffeine, phenacetin, benzocaine, lidocaine, procaine, paracetamol and levamisole) in seized samples, in addition to sibutramine and ephedrine in food supplements and herbal supplements. In the methods proposed in this work, the samples require only one step of dissolution in the supporting electrolyte prior to injection into the BIA cell. A SWV scanning is then performed on the injected sample which is electrochemically oxidized on a boron doped diamond electrode (BDDE), resulting in an unique voltammetric profile. Using optimized experimental conditions, a linear range of 6 to 30 mg L-1 was obtained for cocaine, with a detection limit of 0.27 mg L-1. The accuracy of the method was evaluated comparing results obtained by gas chromatography. SWV and BDDE were also used to determine the presence of adulterants, such as, sibutramine and ephedrine in spiked samples and/or natural dietary supplements used for weight loss purposes. The detection and screening of sibutramine was possible even in highly complex samples such as multivitamins. Studies have shown a linear response for sibutramine from 5 to 50 mg L-1 and a detection limit of 0.08 mg L-1. The SWV method developed for sibutramine was also easily adaptable to the BIA system. The study for the determination of ephedrine in dietary, herbal supplements and urine was carried out using a BIA-SWV system. A linear range of 5 to 40 mg L-1 with detection limit of 0.13 mg L-1 was achieved for ephedrine in 0.1 mol L-1 acetic acid / acetate buffer, pH 4.75. The use of the screening protocols developed in this work have shown to be promising and interesting tools for applications in criminal and sports forensic analysis. Additionally, quantification methods were described for the species of interest in different samples.
Palabras clave: Química Forense
Voltametria de Onda Quadrada
Análise por injeção em batelada
Triagem
Amostras apreendidas
Suplementos alimentares
Química
Toxicologia forense
Voltametria
Química analítica
Forensic Chemistry
Square Wave Voltammetry
Batch injection analysis
Screening
Seized samples
Food supplements
Área (s) del CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::ELETROANALITICA
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Química
Cita: FREITAS, Jhonys Machado de. Desenvolvimento de métodos eletroanalíticos simples, portáteis e de baixo custo para aplicações em análises forenses. 2019. 119 f. Tese (Doutorado em Química) – Universidade Federal de Uberlândia, Uberlândia, 2019. DOI http://dx.doi.org/10.14393/ufu.te.2019.317
Identificador del documento: http://dx.doi.org/10.14393/ufu.te.2019.317
URI: https://repositorio.ufu.br/handle/123456789/24571
Fecha de defensa: 18-feb-2019
Aparece en las colecciones:TESE - Química

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
DesenvolvimentoMetodosEletroanaliticos.pdf5.09 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.