Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/17714
Document type: Dissertação
Access type: Acesso Aberto
Title: Aplicação de espectroscopia no infravermelho médio e calibração multivariada para quantificação de adulterantes e teor em biodiesel de óleo de palma com óleo de soja, soja residual e diesel
Author: Teles, Edvando Souza
First Advisor: Santos, Douglas Queiroz
First member of the Committee: Oliveira, Carlos Alberto de
Second member of the Committee: Rodrigues, Emanuel Carlos
Third member of the Committee: Santos, Douglas Queiroz
Summary: No presente trabalho foram desenvolvidas e validadas metodologias baseadas no uso da Espectroscopia no Infravermelho Médio (MIR) aliada à calibração multivariada por Quadrados Mínimos Parciais (PLS) para a quantificação de adulterantes como óleo de soja e óleo de soja residual nos biodieseis metílicos e etílicos de palma na faixa de concentração de 0,25 a 30,00 (%), bem como determinação de teor de biodiesel metílico e etílico de palma em suas misturas binárias com diesel na faixa de concentração de 0,25 a 30,00 (%). Os resultados das previsões demonstraram que os modelos PLS construídos são satisfatórios. Os Erros Quadrático Médio de Previsão (RMSEP) das adulterações e determinação de teor apresentaram valores de 0,2260(%), com erro médio (EM) com valor menor que 1,93(%). Os modelos também apresentaram uma ótima correlação entre os valores reais e previstos, ficando acima de 0,99974. Não foram observados erros sistemáticos, conforme a norma ASTM E1655-05. Assim sendo os modelos PLS construídos podem ser uma alternativa promissora no controle de qualidade deste combustível quanto a possíveis adulterações ou determinação de teor.
Abstract: In this work, it was developed and validated methodologies that were based on the use of Infrared Spectroscopy Mid (MIR) combined with multivariate calibration Square Partial Least (PLS) to quantify adulterants such as soybean oil and residual soybean oil in methyl and ethyl palm biodiesels in the concentration range from 0.25 to 30.00 (%), as well as to determine methyl and ethyl palm biodiesel content in their binary mixtures with diesel in the concentration range from 0.25 to 30.00 (%). The prediction results showed that PLS models constructed are satisfactory. Errors Mean Square Forecast (RMSEP) of adulteration and content determination showed values of 0.2260 (%), with mean error (EM) with values below 1.93 (%). The models also showed a strong correlation between actual and predicted values, staying above 0.99974. No systematic errors were observed, in accordance to ASTM E1655- 05. Thus the built PLS models, may be a promising alternative in the quality control of this fuel for possible adulterations or to content determination.
Keywords: Biocombustíveis
Espectroscopia de infravermelho
Quimiometria
FT-MIR
PLS
Controle de Qualidade
Biofuel
Chemometrics
Quality Control
Area (s) of CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Biocombustíveis
Quote: TELES, Edvando Souza. Aplicação de espectroscopia no infravermelho médio e calibração multivariada para quantificação de adulterantes e teor em biodiesel de óleo de palma com óleo de soja, soja residual e diesel. 2016. 77 f. Dissertação (Mestrado em Biocombustíveis) - Universidade Federal de Uberlândia, Uberlândia, 2016. DOI http://doi.org/10.14393/ufu.di.2016.371
Document identifier: http://doi.org/10.14393/ufu.di.2016.371
URI: https://repositorio.ufu.br/handle/123456789/17714
Date of defense: 24-Jun-2016
Appears in Collections:DISSERTAÇÃO - Biocombustíveis

Files in This Item:
File Description SizeFormat 
AplicacaoEspectroscopiaInfravermelho.pdfDissertação5.53 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.