Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/16985
Tipo de documento: Dissertação
Tipo de acceso: Acesso Aberto
Título: Carga de fratura de cantiléveres de protocolos mandibulares confeccionados por meio de duas formas alternativas
Autor: Brant Filho, Adalberto Caldeira
Primer orientador: Neves, Flávio Domingues das
Primer miembro de la banca: Gonçalves, Luiz Carlos
Segundo miembro de la banca: Borges, Gilberto Antônio
Resumen: O objetivo da pesquisa foi testar e comparar a resistência mecânica de cantiléveres confeccionados de duas maneiras alternativas: pelo processo de soldagem por arco voltaico com argônio, solda TIG (n=10) e Barra Distal Neodent® (Curitiba, PR, Brasil) pré fabricada (n=10), comparando com o modelo atualmente mais utilizado que é a barra de Cobalto Cromo (Co-Cr) fundida e soldada (n=10). Todas as amostras foram submetidas a flexão em máquina de ensaio universal (EMIC 2000 DL, São José dos Pinhais PR,-Brasil) com célula de carga de 1000N. Os dados foram submetidos a análise de variância para verificar diferenças estatísticas entre os grupos (α=5%), e o teste Tukey foi escolhido para análise entre grupos. Foram observadas diferenças estatísticas significantes entre o grupo fundido e soldado Co-Cr (1617,800 ± 285,160 N) em relação aos grupos TIG (520,360 ± 199,193N) e Barra Distal Neodent (592,200 ± 105,014 N), não houve diferença estatística entre os grupos TIG e Barra Distal Neodent® (Curitiba, PR, Brasil). Foi concluído que as técnicas alternativas estudadas apresentam resistência compatível com o esforço mastigatório e podem ser utilizadas para a confecção de infraestruturas protéticas na reabilitação de pacientes desdentados, desde que o carregamento oclusal seja favorável, a diferença observada sugere que situações clínicas que sugiram grandes carregamentos ainda devam ser resolvidas com a barra tradicional.
Abstract: The aim of this study was to evaluate the mechanical strength of cantilevers manufactured in two alternative ways: by the process of welding using voltaic arc with argon, welder TIG (n=10) and prefabricated Neodent® (Curitiba, PR, Brasil) Distal Bar (n=10), compared to the currently more adopted model, which is cobalt chrome bar (Co-Cr) fused and welded (n=10). All samples were subjected to loading test in universal testing machine (EMIC 2000DL São José dos Pinhais -PR, Brazil). The data were analyzed by variance of analysis to verify statistical differences among groups (α=5%), Tukey s test was chosen for group analysis. We observed statistical differences among fused and welded group Co-Cr (1617,800 ± 285,160 N) in comparison to TIG (520,360 ± 199,193 N) and Neodent Distal Bar (592,200 ± 105,014 N), there was not statistical difference between groups TIG and Barra Distal Neodent® (Curitiba, PR, Brasil). It was concluded that the alternative techniques present strength compatible to masticatory stress and can be used in manufacturing of metal frameworks in oral rehabilitation of edentulous patients, once the occlusal loading is favorable and has a small cantilever, the observed difference suggests that clinical conditions that requires large loadings still must be resolved with traditional bar.
Palabras clave: Resistência à compressão
Solda TIG
Barra distal neodent®
Solda laser
Co-Cr
Compressive strength
TIG solder
Neodent® distal bar
Laser solder
Prótese dentária- Resistência
Área (s) del CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
Idioma: por
País: BR
Editora: Universidade Federal de Uberlândia
Sigla de la institución: UFU
Departamento: Ciências da Saúde
Programa: Programa de Pós-graduação em Odontologia
Cita: BRANT FILHO, Adalberto Caldeira. Carga de fratura de cantiléveres de protocolos mandibulares confeccionados por meio de duas formas alternativas. 2014. 59 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de Uberlândia, Uberlândia, 2014. DOI https://doi.org/10.14393/ufu.di.2014.170
Identificador del documento: https://doi.org/10.14393/ufu.di.2014.170
URI: https://repositorio.ufu.br/handle/123456789/16985
Fecha de defensa: 27-feb-2014
Aparece en las colecciones:DISSERTAÇÃO - Odontologia

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CargaFraturaCantileveres.pdf1.94 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.