Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/50568
ORCID:  http://orcid.org/0000-0001-5192-4690
Document type: Tese
Access type: Acesso Embargado
Embargo Date: 2028-07-28
Title: Veracidade do escaneamento intraoral em reabilitações implantossuportadas de arco total: efeito da esterilização de scanbodies e dos marcadores de posicionamento
Alternate title (s): Trueness of intraoral scanning for full-arch implant rehabilitation: effect of scanbody sterilization and positioning markers
Author: Santos, Fábio Henrique de Paulo Costa
First Advisor: Zancopé, Karla
First member of the Committee: Neves, Flávio Domingues das
Second member of the Committee: Camargos, Germana de Villa
Third member of the Committee: Mendonça, Gustavo
Fourth member of the Committee: Moura, Guilherme Faria
Summary: O estudo dos fatores capazes de influenciar a veracidade dos escaneamentos intraorais é essencial para aumentar a previsibilidade dos fluxos digitais em Implantodontia. O objetivo geral desta tese foi avaliar fatores que influenciam a veracidade do escaneamento intraoral em reabilitações implantossuportadas de arco total. Três objetivos específicos integraram este estudo. Objetivo específico 1: avaliar o efeito de ciclos repetidos de esterilização em autoclave sobre a estabilidade dimensional, os desvios superficiais e a adaptação marginal de scanbodies confeccionados em diferentes materiais. Objetivo específico 2: descrever e aplicar clinicamente um fluxo digital utilizando marcadores de posicionamento impressos em 3D para reabilitação implantossuportada bimaxilar de arco total. Objetivo específico 3: avaliar clinicamente o efeito de marcadores de posicionamento mucossuportados na veracidade do escaneamento intraoral de mandíbulas edêntulas reabilitadas com próteses implantossuportadas de arco total, bem como sua influência sobre o tempo clínico e a satisfação dos pacientes. A partir dos resultados obtidos, observou-se que ciclos repetidos de esterilização promoveram maiores desvios superficiais em scanbodies confeccionados em poliéter-éter-cetona (PEEK) quando comparados aos confeccionados em titânio, embora todos os componentes avaliados tenham permanecido dentro de limites clinicamente aceitáveis. A aplicação clínica de marcadores de posicionamento impressos em 3D mostrou-se viável e facilitou o alinhamento de conjuntos de dados digitais durante reabilitações implantossuportadas de arco total. Além disso, a utilização de marcadores de posicionamento mucossuportados promoveu aumento significativo da veracidade dos escaneamentos intraorais quando comparada às moldagens convencionais e aos escaneamentos realizados sem marcadores. Os fluxos digitais demandaram menor tempo clínico e proporcionaram maior satisfação aos pacientes quando comparados às técnicas convencionais. A utilização dos marcadores não aumentou o tempo de execução dos procedimentos e não influenciou negativamente a aceitação dos pacientes. Conclui-se que a veracidade do escaneamento intraoral para reabilitações implantossuportadas de arco total é influenciada tanto por fatores relacionados aos scanbodies quanto por estratégias empregadas durante a aquisição digital.
Abstract: Understanding and controlling variables that affect the trueness of intraoral scanning is essential for improving the predictability of full-arch digital workflows. The overall objective of this thesis was to evaluate factors influencing the trueness of intraoral scanning in full-arch implant-supported rehabilitation. Three specific objectives were investigated. Specific objective 1: to evaluate the effect of repeated autoclave sterilization cycles on the dimensional stability, surface deviation, and marginal fit of scanbodies manufactured from different materials. Specific objective 2: to describe and clinically apply a digital workflow using 3D-printed positioning markers for bimaxillary full-arch implant-supported rehabilitation. Specific objective 3: to evaluate the effect of mucosa-supported positioning markers on the trueness of intraoral scanning in edentulous mandibles rehabilitated with full-arch implant-supported prostheses, as well as their influence on clinical procedure time and patient satisfaction. Based on the findings of these studies, it was observed that repeated autoclave sterilization cycles promoted greater surface deviation in polyetheretherketone (PEEK) scanbodies than in titanium scanbodies, although all evaluated components remained within clinically acceptable limits. The clinical application of 3D-printed positioning markers proved feasible and facilitated digital dataset alignment during complete-arch implant rehabilitation. Furthermore, the use of mucosa-supported positioning markers significantly improved the trueness of intraoral scanning when compared with conventional impressions and digital scanning without markers. Digital workflows required less clinical time and resulted in higher patient satisfaction than conventional impression techniques. The incorporation of positioning markers did not increase procedure time and did not negatively affect patient acceptance. It may be concluded that the trueness of intraoral scanning for full-arch implant-supported rehabilitation is influenced by both scanbody-related factors and scanning strategies.
Keywords: Intraoral Scanning
Trueness
Scanbody
Fiducial Markers
Escaneamento intraoral
Veracidade
Marcadores de posicionamento
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE
Subject: Odontologia
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Odontologia
Quote: SANTOS, Fábio Henrique de Paulo Costa. Veracidade do escaneamento intraoral em reabilitações implantossuportadas de arco total: efeito da esterilização de scanbodies e dos marcadores de posicionamento. 2026. 53 f. Tese (Doutorado em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2026. DOI http://doi.org/10.14393/ufu.te.2026.586.
Document identifier: http://doi.org/10.14393/ufu.te.2026.586
URI: https://repositorio.ufu.br/handle/123456789/50568
Date of defense: 28-Jul-2026
Sustainable Development Goals SDGs: ODS::ODS 9. Indústria, Inovação e infraestrutura - Construir infraestrutura resiliente, promover a industrialização inclusiva e sustentável, e fomentar a inovação.
Appears in Collections:TESE - Odontologia

Files in This Item:
File Description SizeFormat 
VeracidadeEscaneamentoIntraoral .pdf
  Until 2028-07-28
TESE DE DOUTORADO868.78 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons