Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/50360
ORCID:  http://orcid.org/0009-0003-0536-329X
Document type: Trabalho de Conclusão de Curso
Access type: Acesso Aberto
Title: Aplicação de estabilidade em uma clínica odontológica de pequeno porte
Alternate title (s): Application of stability in a small-sized dental clinic
Author: Oliveira, Pedro Henrique Silva
First Advisor: Castillo, Lucio Abimael Medrano
First member of the Committee: Andrade, Augusto Perez de
Second member of the Committee: Borba, Leonardo Mortari
Summary: A gestão de clínicas odontológicas de pequeno porte costuma concentrar esforços na excelência clínica e negligenciar os processos de apoio, o que gera desperdícios de materiais, atrasos e sobrecarga das equipes. Este trabalho propõe a implementação do conceito de estabilidade operacional do Lean Healthcare no setor de apoio de uma clínica odontológica de pequeno porte, com foco no almoxarifado e na central de material esterilizado. A pesquisa, de natureza aplicada e abordagem quali-quantitativa, foi conduzida pelo método da pesquisa-ação, com observação participante, auditoria de inventário, estudo de tempos e registro fotográfico, e estruturada pelo Relatório A3 e por três diagramas de Ishikawa adaptados aos 6Ms, um para cada efeito medido. O diagnóstico identificou perdas de R$ 7.190,00 anuais com materiais vencidos, tempo de preparação de salas de 40 minutos e até cinco interrupções por cirurgia para busca de itens, em uma operação de aproximadamente 130 cirurgias de setup completo por ano. As contramedidas implementadas (5S com gestão visual no estoque, sistema PEPS, kits cirúrgicos padronizados e procedimento operacional padrão para a montagem das salas) reduziram o tempo de preparação para 15 minutos (62,5%), zeraram as interrupções cirúrgicas, estancaram o descarte de materiais por validade e eliminaram uma despesa média de R$ 46,00 mensais com frete emergencial, liberando cerca de 50 horas anuais do recurso gargalo. Conclui-se que a estabilização dos 6Ms é um pré-requisito viável e de baixo custo para a melhoria contínua em serviços odontológicos.
Abstract: Small dental clinics usually focus on clinical excellence while neglecting support processes, which leads to material waste, delays and team overload. This work proposes the implementation of the Lean Healthcare operational stability concept in the support sector of a small dental clinic, focusing on the storeroom and the sterilization center. The research, applied in nature and with a quali-quantitative approach, was conducted through action research, with participant observation, inventory audit, time study and photographic records, structured by the A3 Report and three Ishikawa diagrams adapted to the 6Ms, one for each measured effect. The diagnosis identified losses of BRL 7,190.00 per year in expired materials, a 40-minute room setup time and up to five interruptions per surgery to search for missing items, in an operation of approximately 130 full-setup surgeries per year. The implemented countermeasures (5S with visual management, FIFO system, standardized surgical kits and a standard operating procedure for room assembly) reduced setup time to 15 minutes (62.5%), eliminated surgical interruptions, stopped the disposal of expired materials and removed an average monthly expense of BRL 46.00 on emergency freight, freeing about 50 hours per year of the bottleneck resource. The stabilization of the 6Ms proves to be a feasible, low-cost prerequisite for continuous improvement in dental services.
Keywords: Lean Healthcare
Lean Healthcare
Estabilidade operacional
Operational stability
Odontologia
Dentistry
5S
5S
Padronização
Standardization
Area (s) of CNPq: CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Quote: OLIVEIRA, Pedro Henrique Silva. Aplicação de estabilidade em uma clínica odontológica de pequeno porte. 2026. 73 f. Trabalho de Conclusão de Curso (Graduação em Engenharia Mecatrônica) – Universidade Federal de Uberlândia, Uberlândia, 2026.
URI: https://repositorio.ufu.br/handle/123456789/50360
Date of defense: 14-Aug-2026
Appears in Collections:TCC - Engenharia Mecatrônica

Files in This Item:
File Description SizeFormat 
AplicacaoEstabilidadeClinica.pdfTCC4.15 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons