Please use this identifier to cite or link to this item:
https://repositorio.ufu.br/handle/123456789/50158| ORCID: | http://orcid.org/0000-0002-6992-7272 |
| Document type: | Dissertação |
| Access type: | Acesso Embargado |
| Embargo Date: | 2028-07-24 |
| Title: | Tomografia de impedância elétrica e sua aplicabilidade em unidades de terapia intensiva neonatal: revisão de escopo |
| Alternate title (s): | Electrical impedance tomography and Its applicability in neonatal intensive care units: a scoping review |
| Author: | Borges, Marília Carvalho |
| First Advisor: | Azevedo, Vivian Mara Gonçalves de Oliveira |
| First coorientator: | Azevedo, Ingrid Guerra |
| First member of the Committee: | Nascimento, Milena Siciliano |
| Second member of the Committee: | Ronchi, Carlos Fernando |
| Summary: | Introdução: Os avanços da terapia intensiva neonatal têm ampliado a sobrevida de recém-nascidos, especialmente os prematuros extremos, ao mesmo tempo em que aumentam a incidência de morbidades respiratórias e a necessidade de estratégias ventilatórias individualizadas. Nesse cenário, o monitoramento da mecânica respiratória é fundamental para otimizar a ventilação mecânica e minimizar a ocorrência de lesões pulmonares associadas ao suporte ventilatório em neonatos internados em unidades de terapia intensiva (UTIs). Embora eficazes, tecnologias tradicionais podem ser limitadas na identificação precoce de complicações pulmonares e na personalização do suporte ventilatório. Nesse contexto, diversas tecnologias emergentes têm sido desenvolvidas para aprimorar esse monitoramento. A tomografia de impedância elétrica (TIE) surge como uma ferramenta promissora por fornecer imagens em tempo real, não invasiva e livres de radiação, permitindo o ajuste dinâmico dos parâmetros ventilatórios. Apesar das limitações técnicas e operacionais, seu uso tem se expandido na neonatologia devido ao potencial de melhorar a segurança e eficácia do manejo respiratório. Sendo assim, este estudo tem como objetivo mapear e analisar as evidências científicas sobre a aplicabilidade da TIE em neonatos internados em UTIs, identificar os parâmetros funcionais da TIE mais utilizados, os efeitos adversos e os benefícios do uso da TIE, além das contribuições. Métodos: Esta revisão de escopo foi realizada conforme as diretrizes do Joanna Brigs Institute (JBI) e o checklist PRISMA-ScR e o protocolo publicado. As buscas foram realizadas nas bases PubMed, Embase, CINAHL, Web of Science e Cochrane Library. Foram elegíveis estudos clínicos e observacionais que avaliaram o uso da TIE em neonatos em UTIs, publicados em inglês, espanhol ou português, sem restrição de data. Dois revisores independentes realizam a triagem, a seleção dos estudos e a extração de dados, com a resolução de conflitos por um terceiro revisor. Os dados foram extraídos e sintetizados de forma descritiva e categorizados de acordo com as perguntas da revisão. Apesar de não ser exigência da revisão de escopo, foi realizada uma avaliação da qualidade metodológica dos estudos incluídos para subsidiar a interpretação dos achados e contextualizar a robustez das evidências. Resultados: Foram incluídos 19 estudos, predominantemente observacionais, que investigaram o uso da TIE em neonatos internados em UTIs com suporte respiratório. A TIE foi utilizada principalmente para avaliação da distribuição regional da ventilação e monitorização do volume pulmonar, acompanhamento do impacto das intervenções na aeração pulmonar e otimização dos parâmetros ventilatórios em neonatos críticos. A variação da impedância e do volume pulmonar expiratório foram os principais parâmetros avaliados pela TIE na população neonatal. Considerações finais: De maneira geral, os estudos destacaram o potencial da TIE como ferramenta para avaliação dinâmica e não invasiva da função pulmonar à beira leito, Em comparação aos métodos tradicionais, a TIE oferece uma avaliação regional e em tempo real da ventilação pulmonar, superando as limitações das abordagens estáticas e baseadas em medidas globais. Contudo, a transição da TIE da pesquisa para a prática clínica rotineira nas UTIs depende da superação de barreiras metodológicas e estruturais, como a resolução espacial limitada, o custo elevado e a necessidade de treinamento especializado da equipe assistencial. Soma-se a isso a ausência de valores de referência padronizados para a população neonatal e a falta de consenso sobre protocolos de aquisição e interpretação das imagens entre diferentes centros, o que dificulta a comparação de resultados e a validação em larga escala. |
| Abstract: | Introduction: Advances in neonatal intensive care have increased the survival of newborns—particularly extremely preterm infants—while simultaneously raising the incidence of respiratory morbidities and the need for individualized ventilation strategies. In this context, monitoring respiratory mechanics is crucial for optimizing mechanical ventilation and minimizing ventilator-associated lung injury in neonates admitted to intensive care units (ICUs). Although effective, traditional technologies may have limitations regarding the early detection of pulmonary complications and the personalization of ventilatory support. Consequently, various emerging technologies have been developed to enhance this monitoring. Electrical impedance tomography (EIT) has emerged as a promising tool, offering real-time, non-invasive, and radiation-free imaging that enables the dynamic adjustment of ventilatory parameters. Despite technical and operational limitations, its use in neonatology is expanding due to its potential to improve the safety and efficacy of respiratory management. Therefore, this study aims to map and analyze scientific evidence regarding the applicability of EIT in neonates admitted to NICUs, identifying the most commonly used EIT functional parameters, the adverse effects and benefits of EIT use, and its contributions. Methods: This scoping review was conducted in accordance with the Joanna Briggs Institute (JBI) guidelines, the PRISMA-ScR checklist, and the published protocol. Searches were performed in the PubMed, Embase, CINAHL, Web of Science, and Cochrane Library databases. Clinical and observational studies evaluating the use of EIT in neonates in NICUs—published in English, Spanish, or Portuguese, with no date restrictions—were eligible for inclusion. Two independent reviewers performed study screening, selection, and data extraction, with a third reviewer resolving any conflicts. Data were extracted, descriptively synthesized, and categorized according to the review questions. Although not a requirement for a scoping review, an assessment of the methodological quality of the included studies was conducted to support the interpretation of findings and contextualize the robustness of the evidence. Results: Nineteen studies—predominantly observational—were included, investigating the use of EIT in neonates admitted to ICUs requiring respiratory support. EIT was primarily used to assess regional ventilation distribution and monitor lung volume, track the impact of interventions on lung aeration, and optimize ventilator settings in critically ill neonates. Changes in impedance and expiratory lung volume were the main parameters evaluated by EIT in the neonatal population. Final considerations: Overall, the studies highlighted the potential of EIT as a tool for the dynamic, non-invasive, bedside assessment of lung function. Compared to traditional methods, EIT offers a real-time, regional assessment of pulmonary ventilation, overcoming the limitations of static approaches based on global measurements. However, transitioning EIT from research to routine clinical practice in neonatal ICUs depends on overcoming methodological and structural barriers, such as limited spatial resolution, high costs, and the need for specialized staff training. Added to this are the absence of standardized reference values for the neonatal population and the lack of consensus among centers regarding image acquisition and interpretation protocols, which hinders the comparison of results and large-scale validation. |
| Keywords: | Neonatos Tomografia de impedância elétrica Unidade de terapia intensiva neonatal Suporte respiratório Neonates Electrical impedance tomography Neonatal intensive care unit Respiratory support |
| Area (s) of CNPq: | CNPQ::CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL |
| Subject: | Fisioterapia |
| Country: | Brasil |
| Publisher: | Universidade Federal de Uberlândia |
| Program: | Programa de Pós-graduação em Fisioterapia |
| Quote: | BORGES, Marilia Carvalho. Tomografia de impedância elétrica e sua aplicabilidade em unidades de terapia intensiva neonatal: revisão de escopo. 2026. 75 f. Dissertação (Mestrado em Fisioterapia) - Universidade Federal de Uberlândia, Uberlândia, 2026. DOI: http://doi.org/10.14393/ufu.di.2026.449. |
| Document identifier: | http://doi.org/10.14393/ufu.di.2026.449 |
| URI: | https://repositorio.ufu.br/handle/123456789/50158 |
| Date of defense: | 24-Jul-2026 |
| Sustainable Development Goals SDGs: | ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades. |
| Appears in Collections: | DISSERTAÇÃO - Fisioterapia |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| TomografiaImpedanciaEletrica.pdf Until 2028-07-24 | 1.77 MB | Adobe PDF | View/Open Request a copy |
This item is licensed under a Creative Commons License