Please use this identifier to cite or link to this item:
https://repositorio.ufu.br/handle/123456789/49388| Document type: | Dissertação |
| Access type: | Acesso Embargado |
| Embargo Date: | 2028-07-09 |
| Title: | Análise fractal em imagens odontológicas: estudos comparativos entre modalidades de imagem e parâmetros de aquisição |
| Alternate title (s): | Fractal dimension analysis in dental imaging: Comparative studies of imaging modalities and acquisition parameters |
| Author: | Vieira, Camila Silvério Carvalho |
| First Advisor: | Barbosa, Gabriella Lopes de Rezende |
| First coorientator: | Oliveira, Guilherme José Pimentel Lopes de |
| First member of the Committee: | Oliveira, Guilherme José Pimentel Lopes de |
| Second member of the Committee: | Vaz, Sergio Lins de Azevedo |
| Third member of the Committee: | Pinto, Maria Augusta Visconti Rocha |
| Summary: | Os estudos sobre análise fractal têm demonstrado seu potencial de aplicabilidade em diferentes áreas da Odontologia. Embora um protocolo estruturado para sua aplicação em exames de imagem odontológicos tenha sido proposto há mais de vinte anos, ainda persistem lacunas importantes relacionadas à influência da modalidade de imagem, dos parâmetros de aquisição, do método de processamento e da escolha da região de interesse sobre os valores de dimensão fractal. Nesse contexto, a presente dissertação teve dois objetivos: O primeiro consistiu em comparar diferentes modalidades de imagem (radiografia panorâmica e reconstruções panorâmicas de tomografia computadorizada de feixe cônico com diferentes espessuras) na avaliação da estrutura trabecular óssea por meio da análise fractal. O segundo objetivo foi investigar a influência da miliamperagem, dos métodos de processamento de imagem para análise fractal e das regiões de interesse sobre os valores de dimensão fractal obtidos em imagens de tomografia computadorizada de feixe cônico, bem como analisar o comportamento dessas medidas frente às variações dos fatores mencionados. O primeiro estudo avaliou imagens de 20 pacientes, incluindo radiografias panorâmicas e reconstruções panorâmicas com diferentes espessuras (160 µm; 480 µm; 800 µm; 1,1 mm; 2,1 mm; 3 mm; 4 mm; 5 mm; 10 mm; 14,9 mm; 20 mm; 29,9 mm; 40,2 mm e 50,1 mm). Em cada imagem, regiões de interesse bilaterais foram selecionadas 2 mm superiormente, medialmente e inferiormente ao forame mentual, e os valores de dimensão fractal foram obtidos pelo método de White & Rudolph. Os resultados demonstraram diferenças entre os valores de dimensão fractal obtidos em radiografias panorâmicas e em reconstruções panorâmicas, bem como entre reconstruções mais finas (160 µm e 480 µm) e mais espessas (29,9 mm, 40,2 mm e 50,1 mm). No segundo estudo, foram avaliadas oito mandíbulas humanas edêntulas submetidas à tomografia computadorizada de feixe cônico com sete diferentes configurações de miliamperagem (2, 4, 6,3, 8, 10, 12 e 15). Cortes transversais foram selecionados em cinco regiões de interesse bilaterais (incisiva, canina, pré-molar, primeiro molar e segundo molar), e a análise fractal foi realizada utilizando três métodos de processamento de imagem distintos (White & Rudolph, White & Rudolph revisado e método da escala de cinza). Os resultados indicaram que os valores de dimensão fractal em imagens tomográficas são significativamente influenciados pelo método de processamento de imagem para análise fractal, mas permanecem estáveis diante de variações da miliamperagem e das regiões de interesse no corpo mandibular. De modo geral, os achados desta dissertação demonstram que a dimensão fractal é sensível a fatores metodológicos específicos, reforçando a necessidade de padronização da modalidade de imagem e do protocolo de processamento para análise fractal no acompanhamento longitudinal e na comparação de dados de pacientes. |
| Abstract: | Studies on fractal analysis have demonstrated its potential applicability across different areas of Dentistry. Although the structured protocol for its use in dental imaging was proposed more than twenty years ago, important gaps remain regarding the influence of imaging modality, acquisition parameters, image-processing methods, and the selection of regions of interest. In this context, the present dissertation had two objectives. The first was to compare different imaging modalities (panoramic radiography and panoramic reconstructions obtained from cone beam computed tomography with varying thicknesses) in the assessment of trabecular bone structure using fractal analysis. The second objective was to investigate the influence of milliampere settings, image-processing methods for fractal analysis, and regions of interest on fractal dimension values obtained from cone-beam computed tomography images, as well as to evaluate whether variations in these factors affect fractal dimension values. The first study evaluated images from 20 patients, including panoramic radiographs and panoramic reconstructions with different thicknesses (160 µm; 480 µm; 800 µm; 1.1 mm; 2.1 mm; 3 mm; 4 mm; 5 mm; 10 mm; 14.9 mm; 20 mm; 29.9 mm; 40.2 mm; and 50.1 mm). In each image, bilateral regions of interest were selected 2 mm superior, medial, and inferior to the mental foramen, and fractal dimension values were obtained using the White and Rudolph method. The results demonstrated differences between fractal dimension values obtained from panoramic radiographs and panoramic reconstructions, as well as between thinner reconstructions (160 µm and 480 µm) and thicker reconstructions (29.9 mm, 40.2 mm, and 50.1 mm). In the second study, eight edentulous human mandibles were evaluated using cone beam computed tomography with seven different milliampere settings (2, 4, 6.3, 8, 10, 12, and 15). Cross-sectional slices were selected in five regions of interest bilaterally (incisor, canine, premolar, first molar, and second molar), and fractal analysis was performed using three different image-processing methods (White and Rudolph, revised White and Rudolph, and the gray-scale method). The results indicated that fractal dimension values in tomographic images are significantly influenced by the image processing method used for fractal analysis but remain stable across variations in milliampere settings and regions of interest within the mandibular body. Overall, the findings of this dissertation demonstrate that fractal dimension is sensitive to specific methodological factors, reinforcing the need for standardization of the imaging modality and processing protocol for fractal analysis in longitudinal follow-up and when comparing patient data. |
| Keywords: | Doses de Radiação Fractais Processamento de Imagem Assistido por Computador Radiografia Panorâmica Tomografia Computadorizada de Feixe Cônico Radiation Dosage Fractals Computer-Assisted Image Processing Panoramic Radiography Cone Beam Computed Tomography |
| Area (s) of CNPq: | CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::RADIOLOGIA ODONTOLOGICA |
| Subject: | Odontologia Fractais - Programas de computador Radiografia - Qualidade da imagem |
| Language: | por |
| Country: | Brasil |
| Publisher: | Universidade Federal de Uberlândia |
| Program: | Programa de Pós-graduação em Odontologia |
| Quote: | VIEIRA, Camila Silvério Carvalho. Análise fractal em imagens odontológicas: estudos comparativos entre modalidades de imagem e parâmetros de aquisição. 2026. 69 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2026. DOI http://doi.org/10.14393/ufu.di.2026.465. |
| Document identifier: | http://doi.org/10.14393/ufu.di.2026.465 |
| URI: | https://repositorio.ufu.br/handle/123456789/49388 |
| Date of defense: | 9-Jul-2026 |
| Sustainable Development Goals SDGs: | ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades. |
| Appears in Collections: | DISSERTAÇÃO - Odontologia |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| AnáliseFractalImagens.pdf Until 2028-07-09 | Dissertação ou Tese | 13.39 MB | Adobe PDF | View/Open Request a copy |
This item is licensed under a Creative Commons License