Use este identificador para citar ou linkar para este item: https://repositorio.ufu.br/handle/123456789/44849
ORCID:  http://orcid.org/0000-0002-7427-6873
Tipo do documento: Dissertação
Tipo de acesso: Acesso Embargado
Término do embargo: 2027-02-13
Título: HematocritRuler: determinação do hematócrito de Bothrops moojeni HOGE, 1966 baseado em smartphones
Título(s) alternativo(s): HematocritRuler: smartphone-based hematocrit measurement in Bothrops moojeni HOGE, 1966
HematocritRuler: determinación del hematocrito en Bothrops moojeni HOGE, 1966 mediante smartphones
Autor(es): Queiroz, Jéssica Santos
Primeiro orientador: Santos, André Luiz Quagliatto
Primeiro coorientador: Costa, Márcio Machado
Primeiro membro da banca: Hirano, Líria Queiroz Luz
Segundo membro da banca: Bittar, Joely Ferreira Figueiredo
Resumo: A jararaca-caiçaca (Bothrops moojeni), espécie peçonhenta de relevância clínica no Cerrado brasileiro, demanda métodos hematológicos precisos para monitoramento em cativeiro. Sendo o hematócrito essencial no processo avaliativo, ela é capaz de detectar algumas alterações subclínicas. Porém, tradicionalmente é realizado pelo método manual e requer volumes relativamente altos de sangue para algumas espécies de répteis. Diante disso, este estudo teve como objetivo validar um método digital alternativo para a medição do Ht por meio do aplicativo HematocritRuler, avaliando sua acurácia, precisão e reprodutibilidade interobservador em comparação com a técnica tradicional. Para isso, foram analisadas amostras de 48 exemplares adultos e saudáveis de B. moojeni, sendo 24 fêmeas e 24 machos, oriundos do criatório comercial Pentapharm do Brasil Comércio e Exportação LTDA (grupo DSM), localizado em Uberlândia, Minas Gerais, destinado à extração de peçonha de serpentes. Foram colhidas amostras sanguíneas (n=48) de B. moojeni por punção do plexo venoso vertebral, utilizando seringas de 3 mL com agulhas 24G, respeitando um volume máximo de 1% da massa corporal. As amostras foram acondicionadas em microtubos com EDTA K2 e mantidas a 4°C. O hematócrito foi mensurado por dois métodos: (i) régua de micro-hematócrito: centrifugação de tubos capilares preenchidos com 50 µL de sangue e leitura manual; e (ii) HematocritRuler: medições diretas e indiretas de tubos com 10, 15, 25 e 50 µL. As imagens foram capturadas em um sistema padronizado com iluminação controlada e analisadas por dois avaliadores com diferentes níveis de experiência. O desempenho do aplicativo foi comparado ao método tradicional para avaliar sua acurácia, precisão e reprodutibilidade. Os resultados demonstraram concordância quase perfeita entre os métodos para 50 µL (CCC = 0,9914; erro total = 4,89%) e 25 µL (CCC = 0,9864; erro total = 6,88%), dentro dos limites aceitáveis pela ASVCP (<10%). Para 15 µL, o ajuste estatístico reduziu o erro total para 6,14% (CCC = 0,9879), validando sua aplicação pós-calibração. A reprodutibilidade interobservadores atingiu CCC = 0,9982 (50 µL), e a concordância interdispositivos (Xiaomi/Motorola) manteve-se CCC > 0,94 mesmo em volumes mínimos (10 µL). Conclui-se que o HematocritRuler é válido para Ht em volumes ≥15 µL, com precisão comparável ao padrão-ouro, reduzindo em até 70% o volume da amostra e ampliando o monitoramento hematológico em animais de pequeno porte.
Abstract: The brazilian lancehead (Bothrops moojeni), a clinically relevant venomous species in the Brazilian Savanah, requires precise hematological methods for monitoring in captivity. As hematocrit is essential in the evaluation process, it can detect some subclinical changes. However, it is traditionally performed using the manual method and requires relatively high blood volumes for some reptile species. Given this, this study aimed to validate an alternative digital method for measuring Ht using the HematocritRuler application, evaluating its accuracy, precision, and interobserver reproducibility compared to the traditional technique. For this purpose, samples from 48 healthy adult B. moojeni specimens, comprising 24 females and 24 males, were analyzed. These specimens were sourced from the commercial breeding facility Pentapharm do Brasil Comércio e Exportação LTDA (DSM group), located in Uberlândia, Minas Gerais, which is dedicated to snake venom extraction. Blood samples (n=48) were collected from B. moojeni by puncture of the vertebral venous plexus using 3 mL syringes with 24G needles, respecting a maximum volume of 1% of body mass. The samples were stored in microtubes with EDTA K2 and kept at 4°C. Hematocrit was measured by two methods: (i) micro-hematocrit ruler: centrifugation of capillary tubes filled with 50 µL of blood and manual reading; and (ii) HematocritRuler: direct and indirect measurements of tubes with 10, 15, 25, and 50 µL. Images were captured in a standardized system with controlled lighting and analyzed by two evaluators with different levels of experience. The performance of the application was compared to the traditional method to assess its accuracy, precision, and reproducibility. The results demonstrated almost perfect agreement between the methods for 50 µL (CCC = 0.9914; total error = 4.89%) and 25 µL (CCC = 0.9864; total error = 6.88%), within the limits acceptable by ASVCP (<10%). For 15 µL, statistical adjustment reduced the total error to 6.14% (CCC = 0.9879), validating its application post-calibration. Interobserver reproducibility reached CCC = 0.9982 (50 µL), and inter-device agreement (Xiaomi/Motorola) remained CCC > 0.94 even at minimal volumes (10 µL). It is concluded that HematocritRuler is valid for Ht in volumes ≥15 µL, with accuracy comparable to the gold standard, reducing sample volume by up to 70% and expanding hematological monitoring in small animals.
Palavras-chave: serpentes
snakes
jararaca-caiçaca
brazilian lancehead
sangue
blood
volume globular
packed cell volume
Android
Android
Área(s) do CNPq: CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA::PATOLOGIA ANIMAL::PATOLOGIA CLINICA ANIMAL
Assunto: Veterinária
Cobras venenosas - Veneno
Jararaca (Cobra)
Aplicativos móveis
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Ciências Veterinárias
Referência: QUEIROZ, Jéssica Santos. HematocritRuler: determinação do hematócrito de Bothrops moojeni HOGE, 1966 baseado em smartphones. 2025. 76 f. Dissertação (Mestrado em Ciências Veterinárias) - Universidade Federal de Uberlândia, Uberlândia, 2025. DOI http://doi.org/10.14393/ufu.di.2025.17
Identificador do documento: http://doi.org/10.14393/ufu.di.2025.17
URI: https://repositorio.ufu.br/handle/123456789/44849
Data de defesa: 7-Fev-2025
Objetivos de Desenvolvimento Sustentável (ODS): ODS::ODS 15. Vida terrestre - Proteger, recuperar e promover o uso sustentável dos ecossistemas terrestres, gerir de forma sustentável as florestas, combater a desertificação, deter e reverter a degradação da Terra e deter a perda da biodiversidade.
Aparece nas coleções:DISSERTAÇÃO - Ciências Veterinárias

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
HematocritRulerDeterminaçãoHematócrito.pdf
  Até 2027-02-13
Dissertação7.11 MBAdobe PDFVisualizar/Abrir    Solictar uma cópia


Este item está licenciada sob uma Licença Creative Commons Creative Commons