Title: Efeito da fonte de luz de alta intensidade na contração pós-gel em resinas de polimerização rápida: análise por extensometria elétrica
Author: Cruz, Matheus Ribeiro da
First Advisor: Carlo, Hugo Lemes
First coorientator: Michelin, Pietra Sanitá
First member of the Committee: Novais, Veridiana Resende
Second member of the Committee: Menezes, Murilo de Sousa
Summary: O objetivo deste trabalho foi o de avaliar o efeito da técnica de fotopolimerização na contração pós-gel de resinas compostas. O trabalho foi desenvolvido através da utilização de uma fonte de luz do tipo LED polywave (Bluephase Powercure – Ivoclare Vivadent, Schaan, Liechtenstein). Dois tipos de compósitos foram utilizados: 1. resina bulk fill convencional (Tetric N-Ceram Bulk Fill – Ivoclare Vivadent, Schaan, Liechtenstein); e 2. resina bulk fill de polimerização ultra-rápida (Tetric Powerfill – Ivoclare Vivadent, Schaan, Liechtenstein). Os materiais foram fotopolimerizados conforme a indicação do fabricante: 20s na potência alta do aparelho (Tetric N-Ceram) e 3s na potência máxima do aparelho (Tetric Powerfill). A contração linear pós-gel foi obtida através de extensiometria (n=5). A ponta da fonte de luz foi mantida a 1 mm de distância da superfície do compósito e os valores de deformação foram coletados pelo período de 5 min. A análise dos dados foi realizada com nível de significância igual a 5%. Foram utilizados os testes ANOVA um fator Tukey. Quanto aos resultados obtidos, verificou-se que as resinas compostas testadas demonstraram diferença significativa de contração pós-gel (p=0,032), sendo que a resina de polimerização ultra-rápida apresentou os menores valores.
Abstract: The aim of this study was to evaluate the effect of the photopolymerization technique on the post-gel shrinkage of composite resins. The study was developed using a polywave LED light source (Bluephase Powercure – Ivoclare Vivadent, Schaan, Liechtenstein). Two types of resin composite were used: 1. conventional bulk fill (Tetric N-Ceram Bulk Fill – Ivoclare Vivadent, Schaan, Liechtenstein); and 2. ultra-fast curing bulk fill (Tetric Powerfill – Ivoclare Vivadent, Schaan, Liechtenstein). The materials were cured according to the manufacturer's instructions: 20s at the high-power mode (Tetric N-Ceram) and 3s at the maximum power (Tetric Powerfill). The linear post-gel shrinkage was obtained by extensiometry (n=5). The tip of the light source was kept 1 mm away from the composite surface and the deformation values were collected for 5 min. Data analysis was performed with a significance level of 5%. One-way ANOVA and Tukey's tests were used. Regarding the results obtained, it was found that the tested resins demonstrated a significant difference in post-gel contraction (p=0.032), with the ultra-fast polymerization resin presenting the lowest values.
Keywords: Resinas Compostas
Polimerização de Resinas Dentárias
Contração de Polimerização
Falha de Restauração Dentária
Composite Resins
Dental Resin Polymerization
Polymerization Shrinkage
Dental Restoration Failure
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::MATERIAIS ODONTOLOGICOS
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Quote: CRUZ, Matheus Ribeiro da. Efeito da fonte de luz de alta intensidade na contração pós-gel em resinas de polimerização rápida: análise por extensometria elétrica. 2024. 18 f. Trabalho de Conclusão de Curso (Graduação em Odontologia) – Universidade Federal de Uberlândia, Uberlândia, 2024.
URI: https://repositorio.ufu.br/handle/123456789/43372
Date of defense: 28-Aug-2024
Appears in Collections:TCC - Odontologia