Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/43243
ORCID:  http://orcid.org/0009-0001-7366-4321
Tipo de documento: Dissertação
Tipo de acceso: Acesso Embargado
Fecha de embargo: 2026-08-04
Título: Validação dos questionários Foot and Ankle Ability Measure (FAAM) e Foot and Ankle Outcome Score (FAOS) para Instabilidade Crônica de Tornozelo
Título (s) alternativo (s): Validation of the Foot and Ankle Ability Measure (FAAM) and Foot and Ankle Outcome Score (FAOS) questionnaires for Chronic Ankle Instability
Autor: Silva, Gabriella Teixeira
Primer orientador: Felicio, Lilian Ramiro
Primer miembro de la banca: Henrique, Carolina Lins
Segundo miembro de la banca: Pedroni, Cristiane Rodrigues
Resumen: A instabilidade crônica de tornozelo (ICT) é uma condição comumente observada em indivíduos fisicamente ativos, que apresentam entorses laterais recorrentes do tornozelo, sensação de falseio, dor e edema, podendo apresentar alterações biomecânicas e na funcionalidade do tornozelo e pé. De acordo com o The International Ankle Consortium (IAC) alguns critérios de seleção para indivíduos com ICT foram estabelecidos, dentre essas especificações, o IAC orienta o uso de questionários de percepção avaliativos e discriminativos. O Identification of Functional Ankle Instability (IdFAI), como um instrumento de seleção de indivíduos com ICT e os Foot and Ankle Ability Measure (FAAM) e Foot and Ankle Outcome Score (FAOS) que verificam a funcionalidade do tornozelo e pé, são os mais usados. Entretanto, para a utilização de instrumentos de medida relatada pelo paciente (PROM’s) é necessário avaliar e mensurar as propriedades de medidas para verificar se os PROM’s são capazes de mensurar efetivamente seus domínios e subescalas em determidas condições. Apesar disso, os FAAM e FAOS apresentaram déficits metodológicos e propriedades de medidas ainda não apresentadas para indivíduos ativos com ICT, o que impactaria na avaliação da funcionalidade. O objetivo do estudo foi validar os instrumentos FAAM e FAOS para indivíduos fisicamente ativos com ICT baseados nas recomendações do Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN). Foram avaliados 167 voluntários separados em grupo validade estrutural e construto, grupo confiabilidade ambos com ICT e grupo controle, em que uma ficha de caracterização esportiva, de lesão e os questionários IdFAI, FAAM e FAOS foram aplicados para classificar todos os indivíduos de acordo com os critérios de inclusão para pesquisa. Para análise estatística, testou-se a validade estrutural das subescalas do FAAM e FAOS através de análise fatorial confirmatória, coeficiente de correlação intraclasse, testes de hipóteses, análise de consistência interna, erro da medida e mínima mudança detectável. Os resultados apontam que os questionários FAAM e FAOS são confiáveis e validados para serem aplicados na população ativa com ICT para avaliação da funcionalidade de acordo com os critérios do COSMIN. Além disso, as subescalas FAOS-Esporte e FAOS-Qualidade de vida são capazes de discriminar indivíduos com ICT com uma pontuação para cada subescala.
Abstract: Chronic ankle instability (CAI) is a condition commonly observed in physically active individuals, who present recurrent lateral ankle sprains, a sensation of distortion, pain and swelling, and may present biomechanical changes and changes in the functionality of the ankle and foot. According to The International Ankle Consortium (IAC), some selection criteria for individuals with ICT have been established. Among these specifications, the IAC guides the use of evaluative and discriminative perception questionnaires. The Identification of Functional Ankle Instability (IdFAI), as an instrument for selecting individuals with CAI, and the Foot and Ankle Ability Measure (FAAM) and Foot and Ankle Outcome Score (FAOS), which check the functionality of the ankle and foot, are the most used. However, in order to use patient-reported measurement instruments (PROM's), it is necessary to evaluate and measure the measurement properties to verify whether the PROM's are capable of effectively measuring their domains and subscales under certain conditions. Despite this, the FAAM and FAOS presented methodological deficits and measurement properties not yet presented for active individuals with CAI, which would impact the assessment of functionality. The objective of the study was to validate the FAAM and FAOS instruments for physically active individuals with CAI based on the recommendations of the Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN). 167 volunteers were evaluated, separated into a structural and construct validity group, a reliability group, both with CAI and a control group, in which a sports and injury characterization form and the IdFAI, FAAM and FAOS questionnaires were applied to classify all individuals according to their inclusion criteria for research. For statistical analysis, the structural validity of the FAAM and FAOS subscales was tested through confirmatory factor analysis, intraclass correlation coefficient, hypothesis tests, internal consistency analysis, measurement error and minimum important change. The results indicate that the FAAM and FAOS questionnaires are reliable and validated to be applied to the active population with CAI to assess functionality according to the COSMIN criteria. Furthermore, the FAOS-Sport and FAOS-Quality of life subscales are able to discriminate individuals with CAI with a score for each subscale.
Palabras clave: Instabilidade Crônica de Tornozelo
funcionalidade
questionários
validação
propriedades de medida
Chronic Ankle Instability
Functionality
questionnaires
measurement properties
validity
Área (s) del CNPq: CNPQ::CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
Tema: Fisioterapia
Tornozelos
Fisioterapia - Questionários
Qualidade de vida e biomecânica
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Fisioterapia
Cita: SILVA, Gabriella Teixeira. Validação dos questionários Foot and Ankle Ability Measure (FAAM) e Foot and Ankle Outcome Score (FAOS) para instabilidade crônica de tornozelo. 2024. 71 f. Dissertação (Mestrado em Fisioterapia) - Universidade Federal de Uberlândia, Uberlândia, 2024. DOI http://doi.org/10.14393/ufu.di.2024.553.
Identificador del documento: http://doi.org/10.14393/ufu.di.2024.553
URI: https://repositorio.ufu.br/handle/123456789/43243
Fecha de defensa: 29-jul-2024
Objetivos de Desarrollo Sostenible (ODS): ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades.
Aparece en las colecciones:DISSERTAÇÃO - Fisioterapia

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
Validaçã questionários Foot.pdf
  Hasta 2026-08-04
Dissertação1.77 MBAdobe PDFVisualizar/Abrir    Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.