Use este identificador para citar ou linkar para este item:
https://repositorio.ufu.br/handle/123456789/29456
Tipo do documento: | Dissertação |
Tipo de acesso: | Acesso Aberto |
Título: | Pontos de corte dos índices dopplervelocimétricos da artéria oftálmica para diagnóstico da pré-eclâmpsia: nova abordagem |
Título(s) alternativo(s): | Cutoff values of the ophthalmic artery Doppler velocimetry to diagnose pacients with preeclampsia: a new approach |
Autor(es): | Menêses, Vítor Fernando Silva de Campos |
Primeiro orientador: | Diniz, Angélica Lemos Debs |
Primeiro membro da banca: | Freitas, Márcia Aires Rodrigues de |
Segundo membro da banca: | Costa, Fabrício da Silva |
Resumo: | Objetivos: Determinar ponto de corte dos índices dopplervelocimétricos da artéria oftálmica (AO) para identificação de pacientes com pré-eclâmpsia (PE) em comparação à pacientes saudáveis. Métodos: Estudo observacional prospectivo envolvendo 266 gestantes no segundo e terceiro trimestres de gestação, 133 com diagnóstico de PE e 133 gestantes saudáveis. Todas as participantes foram submetidas à avaliação Doppler da AO, obtendo-se o Índice de Pulsatilidade (IP), Índice de Resistência (IR), o Pico de Velocidade Sistólica (PVS), o Segundo Pico de Velocidade Sistólica (P2), a Velocidade Diastólica Final (VDF) e Razão entre Picos de Velocidade (RPV), e as médias comparadas por meio do teste t de Student. Para determinação do ponto de corte foi realizada a curva característica de resposta do observador (ROC), com cálculo da sensibilidade (S), especificidade (E) e acurácia (A) para cada variável. Resultados: Na análise ROC, o P2 e RPV exibiram desempenho superior aos demais parâmetros isolados no diagnóstico de PE. Testaram-se dois pontos de corte, o primeiro com RPV ≥ 0.70, obtendo-se A: 88.72%, S: 81.95% e E: 95.48%, e outro ponto de corte de ≥ 0.75, obtendo-se A: 86.24%, S: 74.43% e E: 99.24%. Já o P2 ≥ 21.5 cm/s demonstrou A: 87.59%, S: 84.96% e E: 90.22%. A associação do RPV ≥ 0.70 e P2 ≥ 21.5 cm/s demonstrou: A: 92.48%, S: 95.49% e E: 89.47%. Conclusão: A ultrassonografia com Doppler da AO mostrou-se método complementar factível e de alta performance no diagnóstico de PE. O P2 e RPV foram os índices isolados com melhor desempenho na identificação de gestantes com PE, quando adotado P2 ≥ 21,5 cm/s e RPV ≥ 0.70, porém a associação dos dois índices atingiu melhor performance diagnóstica no que se refere a sensibilidade. A melhor especificidade para detecção da PE foi atingido com a adoção do RPV ≥ 0.75. |
Abstract: | Objectives: To establish a cutoff value of the ophthalmic artery (OA) Doppler velocimetry to diagnose patients with pre-eclampsia (PE), comparing to healthy control patients. Methods: This prospective observational study enrolled 266 women in the second and third trimesters of pregnancy – 133 with PE and 133 healthy pregnant women. All patients were evaluated by OA Doppler sonography to assess its pulsatility index (PI), resistance index (RI), peak systolic velocity (PVS), second peak systolic velocity (P2), end diastolic velocity (EDV), and peak ratio (PR), and to compare the means using Student's T test. A Receiver Operating Characteristics (ROC) curve has been performed to establish the cutoff value, and estimate the sensitivity (S), specificity (Sp), and accuracy (A) of all variables. Results: The ROC curve analysis showed that P2 and PR were superior to the other parameters in PE diagnosis. We tested two cutoff values: (1) using PR ≥ 0.70, we obtained A: 88.72%, S: 81.95%, and Sp: 95.48% and (2) using PR ≥ 0.75, we obtained A: 86.24%, S: 74.43%, and Sp: 99.24%. Yet, by adopting P2 ≥ 21.5 cm/s, we obtained A: 87.59%, S: 84.96%, and Sp: 90.22%. The association of PR ≥ 0.70 and P2 ≥ 21.5 cm/s resulted in A: 92.48%, S: 95.49%, and Sp: 89.47%. Conclusion: The OA Doppler sonography has proven to be an effective and high-performance complementary imaging examination in PE diagnosis. P2 and PR were superior to the other parameters in PE diagnosis when using P2 ≥ 21.5 cm/s and PR ≥ 0.70. However, the association of both P2 and PR resulted in the best diagnostic performance regarding sensitivity. Using PR ≥ 0.75, we achieved the best Sp for PE detection. |
Palavras-chave: | Artéria oftálmica Ophthalmic artery Pré-eclâmpsia Preeclampsia Diagnóstico Diagnosis Doppler |
Área(s) do CNPq: | CNPQ::CIENCIAS DA SAUDE |
Idioma: | por |
País: | Brasil |
Editora: | Universidade Federal de Uberlândia |
Programa: | Programa de Pós-graduação em Ciências da Saúde |
Referência: | MENÊSES, Vítor Fernando Silva de Campos. Pontos de corte dos índices dopplervelocimétricos da artéria oftálmica para diagnóstico da pré-eclâmpsia: nova abordagem. 2020. 40 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de Uberlândia, Uberlândia, 2020. DOI http://doi.org/10.14393/ufu.di.2020.483. |
Identificador do documento: | http://doi.org/10.14393/ufu.di.2020.483 |
URI: | https://repositorio.ufu.br/handle/123456789/29456 |
Data de defesa: | 17-Jun-2020 |
Aparece nas coleções: | DISSERTAÇÃO - Ciências da Saúde |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
PontosCorteIndices.pdf | 2.06 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.