Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufu.br/handle/123456789/26328
ORCID: | http://orcid.org/0000-0002-8587-6743 |
Tipo de documento: | Dissertação |
Tipo de acceso: | Acesso Aberto |
Título: | Tenacidade à fratura e fragilização por hidrogênio de aços de alta resistência e baixa liga |
Título (s) alternativo (s): | Fracture toughness and hydrogen embrittlement of high strength low alloy steels |
Autor: | Melo, Guilherme Freitas |
Primer orientador: | Franco, Sinésio Domingues |
Primer miembro de la banca: | Franco, Sinésio Domingues |
Segundo miembro de la banca: | Oliveira, Sonia Aparecida Goulart de |
Tercer miembro de la banca: | Paes, Marcelo Torres Piza |
Cuarto miembro de la banca: | Bose Filho, Waldek Wladimir |
Resumen: | Os aços de alta resistência e baixa liga são comumente empregados em diversos equipamentos e estruturas marítimas no setor de óleo e gás. Grande parte dos componentes e estruturas submarinas são submetidos à proteção catódica com o intuito de mitigar a sua corrosão em serviço, possibilitando a ocorrência do fenômeno denominado genericamente de fragilização por hidrogênio (FH). Nesta situação, para estes tipos de aplicação, deve-se avaliar a susceptibilidade à fragilização por hidrogênio (SFH) dos materiais. A viga dupla em balanço (DCB), por não depender de equipamentos complexos e pela possibilidade de se ensaiar vários corpos de prova ao mesmo tempo, é uma alternativa para determinação do fator de intensidade de tensão limiar (KTH), o qual é extremamente importante para a especificação de materiais para estas aplicações. Este ensaio está diretamente relacionado à Mecânica da Fratura e à FH, visto que após um determinado período de incubação, a tensão aplicada no entalhe do corpo de prova é responsável por nuclear uma trinca na raiz do entalhe e, em controle de deslocamento, propagá-la até que a taxa de propagação seja aproximadamente nula e, portanto, o valor do fator de intensidade de tensão aplicado (KAP) atinja KTH. Neste trabalho, ensaiaram-se dois aços (C e F) ao ar, obtendo-se as curvas J-R, com a obtenção de KJIC, mostrando que o valor deste parâmetro para o aço F é 49 % maior que para o aço C. Foi observado também que, nos ensaios DCB com proteção catódica a -1,2 VAg/AgCl, o KTH médio foi de 29,59 MPa.m0,5 para o aço C. Entretanto, para o caso do aço F, as condições do ensaio, não propiciaram a nucleação e crescimento sustentável de trinca, sendo observadas a existência de múltiplas trincas com comprimento inferior a 2,5 mm. Assim, para avaliação da susceptibilidade dos dois aços foram realizados ensaios de carregamento em patamares progressivos assistido pelo meio (CPPAM) e verificou-se a SFH do aço F por esse método, indicando que os ensaios DCB para esse material devem ser realizados em condições de tempos maiores, com recirculação forçada da solução aquosa, controle de pH e temperatura. |
Abstract: | High strength low alloys steels are commonly used in a variety of equipment and structures in the offshore oil and gas sector. Subsea components and structures are subject to cathodic protection in order to mitigate their corrosion in service, allowing the occurrence of a process called hydrogen embrittlement (HE). In such scenario, the susceptibility to hydrogen embrittlement (SHE) of the materials must be evaluated. By not depending on complex equipment together with the possibility of testing several specimens at the same time, the Double Cantilever Beam (DCB) is an alternative for determining the threshold stress intensity factor (KTH), which is extremely important for the specification of materials for these applications. This test is directly related to Fracture Mechanics and HE. Therefore, after an incubation period, a force applied on the specimen is responsible for nucleating a crack at the root of the notch in a displacement control, made propagating it until the crack propagation rate is approximately zero and therefore, the value of the applied stress intensity factor (KAP) reaches KTH. In this work, two steels (C and F) were tested in air, obtaining the curves J-R with KJIC as well, showing that steel F has its value around 49 % higher than steel C. It was also observed that in the testing DCB with cathodic protection at -1.2 VAg /AgCl, the average KTH was 29.59 MPa.m0.5 for the C steel. However, for the case of the steel F, the test conditions did not provide a nucleation and a sustainable crack growth, resulting in multiple cracks of less than 2.5 mm in length. Therefore, to evaluate the susceptibility of the two steels, new tests were carried out Rising Step Load (RSL), and it was verified the SHE of the F steel by this method, indicating that the DCB tests for this material should be performed in conditions of longer times with forced aqueous media recirculation, pH control and temperature. |
Palabras clave: | Fragilização por hidrogênio Engenharia mecânica KTH Aço - Fragilização por hidrogênio Tenacidade à fratura Materiais - Processos de fabricação Double Cantilever Beam Aço de alta resistência Carregamento em patamares progressivos assistido pelo meio Ligas de aço |
Área (s) del CNPq: | CNPQ::ENGENHARIAS |
Idioma: | por |
País: | Brasil |
Editora: | Universidade Federal de Uberlândia |
Programa: | Programa de Pós-graduação em Engenharia Mecânica |
Cita: | MELO, Guilherme Freitas. Tenacidade à fratura e fragilização por hidrogênio de aços de alta resistência e baixa liga. 2019. 184 f. Dissertação (Mestrado em Engenharia Mecânica) - Universidade Federal de Uberlândia, Uberlândia, 2019. DOI http://dx.doi.org/10.14393/ufu.di.2019.54. |
Identificador del documento: | http://dx.doi.org/10.14393/ufu.di.2019.54 |
URI: | https://repositorio.ufu.br/handle/123456789/26328 |
Fecha de defensa: | 29-may-2019 |
Aparece en las colecciones: | DISSERTAÇÃO - Engenharia Mecânica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TenacidadeFraturaFragilização.pdf | Dissertação | 17.61 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons