Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufu.br/handle/123456789/25185
Tipo de documento: | Trabalho de Conclusão de Residência |
Tipo de acceso: | Acesso Aberto |
Fecha de embargo: | 2021-04-11 |
Título: | O uso de tubos endotraqueais com cuff na população pediátrica brasileira. |
Título (s) alternativo (s): | The use of cuffed endotracheal tubes in brazilian pediatric population. |
Autor: | Rodrigues, João Paulo Berti Buzzi Rodrigues |
Primer orientador: | Azevedo, Vivian Mara Gonçalves de Oliveira |
Primer coorientador: | Bacci, Suzi Laine Longo dos Santos |
Primer miembro de la banca: | Mello, Liliane Camargo Felix Figueira de |
Segundo miembro de la banca: | Ronchi, Carlos Fernando |
Resumen: | Objetivo: Este estudo buscou identificar e avaliar a prática da utilização de tubos endotraqueais com cuff em Unidades de Terapia Intensiva Neonatais (UTIN), Pediátricas (UTIP) e Pediátricas mistas (UTIPm) do Brasil. Método: Para identificação das UTI no Brasil, foi acessado o Cadastro Nacional de Estabelecimentos de Saúde (CNES) do Ministério da Saúde do Brasil e foram obtidas informações de 693 UTI cadastradas. Estudo transversal analítico tipo survey realizado por meio de um questionário eletrônico enviado para 298 UTIN, UTIP e UTIPm no Brasil. Resultados: Este estudo analisou 146 questionários (49,3% UTIN, 35,6% UTIP e 15,1% UTIPm). A maioria das unidades participantes (78/146) utilizaram tubos endotraqueais com cuff, com predomínio das UTIP (52/78). Foi observado que mais da metade das unidades que utilizaram tubos com cuff, fizeram uso de protocolo de monitoração da pressão do cuff (45/78). O uso de protocolos de monitoração do cuff foi observado nas UTI que tinham serviço de fisioterapia exclusivo (38/61) e naquelas com tempo de atuação do fisioterapeuta 24 horas/dia (25/45). A causa de falha de extubação mais frequentemente relacionada ao uso de tubos com cuff em UTIP foi a obstrução de via aérea alta. Conclusão: No presente survey, houve predomínio do uso de tubos endotraqueais com cuff e da aplicação de protocolo de monitoração da pressão do cuff em UTIP. A utilização de protocolo de monitoração foi mais frequente em UTI com fisioterapeuta exclusivo e com tempo de atuação 24 horas/dia. |
Abstract: | Objective: This study aimed to identify and to evaluate the practical using of cuffed endotracheal tubes on Neonatal (NICU), Pediatric (PICU) and Mixed Pediatric (mPICU) Intensive Care Units of Brazil. Methods: In order to identify the ICU in Brazil, the National Registry of Health Facilities (CNES) of the Ministry of Health of Brazil was accessed and information was obtained from 693 registered ICU. A cross-sectional survey was performed by sending a questionnaire to 298 NICU, PICU and mPICU in Brazil. Results: This study analyzed 146 questionnaires (49,3% NICU, 35,6% PICU and 15,1% mPICU). Most of the participating units (78/146) used cuffed endotracheal tubes with a predominance of the PICU (52/78). The use of cuff pressure monitoring protocols was seen in more than half of the units that used cuffed endotracheal tubes (45/78). Also, the use of cuff pressure monitoring protocols was observed in ICU with exclusive physiotherapy service (38/61) and in the units with physiotherapy service 24 hours a day (25/45). The most common extubation failure cause related to the use of cuffed endotracheal tubes in PICU was the upper airway obstruction. Conclusion: In this survey, there was a high prevalence of cuffed endotracheal tubes use and cuff pressure monitoring protocols application in PICU. The use of the monitoring protocol was most frequent in the ICU with exclusive physiotherapy service and with physiotherapy service 24 hours a day. |
Palabras clave: | Unidade de terapia intensiva neonatal Unidade de terapia intensiva pediátrica Tubo endotraqueal Cuff Pressão intracuff Neonatal intensive care unit Pediatric intensive care unit Intracuff pressure |
Área (s) del CNPq: | CNPQ::CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL |
Idioma: | por |
País: | Brasil |
Editora: | Universidade Federal de Uberlândia |
Cita: | RODRIGUES, João Paulo Berti Buzzi. O uso de tubos endotraqueais com cuff na população pediátrica brasileira. 2019. 24 f. Trabalho de Conclusão de Residência (Programa de Residência em Área Profissional da Saúde) - Universidade Federal de Uberlândia, Uberlândia, 2019. |
URI: | https://repositorio.ufu.br/handle/123456789/25185 |
Fecha de defensa: | 11-abr-2019 |
Aparece en las colecciones: | TCR - Ciências da Saúde |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
UsoTubosEndotraqueais.pdf | TCR Uni/Multi profissional UFU João Paulo Rodrigues | 412.58 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.