Title: Comparação das variáveis pulmonares durante a aspiração endotraqueal com sistema aberto e fechada
Author: Costa, Fernanda Gonçalves
First Advisor: Carvalho, Eliane Maria de
First member of the Committee: Lopes, Célia Regina
Second member of the Committee: Deloroso, Graça Baldo
Summary: Introdução: A aspiração traqueal é essencial para retirada de muco brônquico para os pacientes sob ventilação mecânica. E existe dois sistemas de aspiração um fechado, que não necessita de desconexão do circuito e o aberto que precisa da desconexão e é o mais utilizado. Mas que ainda não se tem evidência cientifica qual seria o mais indicado para aspirar pacientes críticos. Objetivo: Analisar e comparar as variáveis pulmonares, volume corrente (VC), complacência dinâmica (Cdin) e estática (Cest), resistência inspiratória (Rins) e expiratória (Rexp) com aspiração endotraqueal com o sistema aberto e fechado. Metodologia: Os procedimentos foram realizados em um único dia, com intervalo de 3 horas entre um e outro sistema de aspiração. Os dados foram colhidos durante aproximadamente 15 minutos. Para análise estatística utilizou-se o programa SPSS, Foi aplicado teste Shapiro-Wilk para avaliar a normalidade dos dados. As comparações foram realizadas pelo método de Equações de Estimativas Generalizadas para os grupos e momentos e teste complementar de Bonferroni para analisar os momentos. Foram considerados resultados estatisticamente significantes para valores de p < 0,05. Resultados: Não foi observada diferença estatística no volume corrente, complacência estática e dinâmica e resistência inspiratória e expiratória entre os sistemas aberto e fechado. Tambem não foi observada diferença entre os momentos inicial e final da aspiração nestas variáveis, exceto na resistência expiratória com o sistema aberto (p= 0,0238). Conclusão: As aspirações realizadas com sistema aberto e fechado demonstraram paridade nas análises Cest e Cdin, Risnp, VC. Contudo, ocorreu uma diferença estatística no procedimento no sistema aberto, sendo o parâmetro Rexp menor encontrado após a aspiração endotraqueal. Palavras-chave: Aspiração traqueal, Sistemas, mecânica respiratória, fisioterapia.
Abstract: ABSTRACT Introduction: Tracheal aspiration is essential for removal of bronchial mucus for patients under mechanical ventilation. And there are two vacuum systems one closed, which does not require circuit disconnection and the open one that needs the disconnection and is the most used. But that has not yet been scientific evidence which would be the most appropriate to aspire critical patients. Objective: To analyze and compare pulmonary variables, tidal volume (CV), dynamic (Cdn) and static (Cest) compliance, inspiratory (Kidney) and expiratory resistance (Rexp) with endotracheal aspiration with the open and closed system. Methodology: The procedures were performed in a single day, with a 3-hour interval between one and the other aspiration system. Data were collected for approximately 15 minutes. Statistical analysis was performed using the SPSS program. A Shapiro-Wilk test was used to evaluate the normality of the data. The comparisons were performed using the Generalized Estimates Equation method for the groups and moments and Bonferroni complementary test to analyze the moments. Statistically significant results were considered for values of p <0.05. Results: No statistical difference was observed in tidal volume, static and dynamic compliance, and inspiratory and expiratory resistance between open and closed systems. There was also no difference between the initial and final moments of aspiration in these variables, except for the expiratory resistance with the open system (p = 0.0238). Conclusion: Aspirations performed with open and closed system demonstrated parity in the Cest and Cdin, Risnp, VC analyzes. However, there was a statistical difference in the procedure in the open system, with the lowest Rexp parameter found after endotracheal aspiration. Key words: Tracheal aspiration, Systems, respiratory mechanics, physiotherapy.
Notes: Complacência dinâmica, complacência estática, volume pulmonar corrente, resistência inspiratória, resistência expiratória
Keywords: Aspiração traqueal
Sistemas
Mecânica respiratória
Fisioterapia
Tracheal aspiration
Systems
Respiratory mechanics
Physiotherapy
Complacencia estatica
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Quote: COSTA, Fernanda Gonçalves.Comparação das variáveis pulmonares durante a aspiração endotraqueal com sistema aberto e fechada. 2018. 14 f. Trabalho de Conclusão de Curso (Graduação em Fisioterapia) – Universidade Federal de Uberlândia, Uberlândia, 2018.
URI: https://repositorio.ufu.br/handle/123456789/23992
Date of defense: 23-Nov-2018
Appears in Collections:TCC - Fisioterapia

Files in This Item:
File Description SizeFormat 
ComparaçãoVariáveisPulmonares.pdf538.37 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.