Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/23134
ORCID:  http://orcid.org/0000-0001-5969-7170
Document type: Trabalho de Conclusão de Curso
Access type: Acesso Aberto
Title: Monitoramento de fluoreto nas águas de abastecimento público: comparação entre a técnica eletrométrica e a colorimétrica
Alternate title (s): Monitoring of fluoride in public water supply: comparison between electrometric and colorimetric techniques
Author: Lins-Candeiro, Caio Luiz
First Advisor: Faquim, Juliana Pereira da Silva
First coorientator: Paranhos, Luiz Renato
Second member of the Committee: Oliveira, Andréa Gomes
Third member of the Committee: Oliveira, Guilherme José Pimentel Lopes
Fourth member of the Committee: Vilela , Andomar Bruno Fernandes
Summary: A vigilância da concentração de íon flúor na água de abastecimento público visa garantir o equilíbrio entre a incidência de cárie e fluorose dental. O objetivo desta pesquisa foi comparar duas técnicas de aferição de fluoreto na água de abastecimento público e determinar qual delas é melhor para ser utilizada como ferramenta de vigilância em saúde bucal. O checklist STROBE foi utilizado para auxiliar na condução desta pesquisa e relatar os resultados. Tratou-se de um estudo observacional analítico, de caráter prospectivo. Foram coletadas 126 amostras de água, em 21 pontos, durante seis meses seguidos e analisadas por meio da técnica eletrométrica com eletrodo íon seletivo e pela técnica colorimétrica com o SPADNS. A análise estatística foi realizada de maneira descritiva, em seguida, empregou-se o teste ANOVA com múltiplos fatores e o teste t de Student para amostras pareadas. O nível de significância foi fixado em 5% (p < 0,05). Os resultados mostraram que técnica eletrométrica mostrou menor variação (12,3%) quando comparada a técnica colorimétrica (57,4%). Os dados também apresentam que as duas técnicas estudadas demonstram redução na concentração de fluoreto ao longo da rede de abastecimento, mas esta diferença não foi estatisticamente significante. Pode-se concluir que a técnica eletrométrica é a de melhor escolha para ser utilizada por laboratórios que realizam Vigilância em Saúde Bucal.
Abstract: The monitoring of fluoride ion concentration in the public water supply aims to ensure a balance between the incidence of dental caries and dental fluorosis. The objective of this research was to compare two techniques of fluoride gauging in public water supply and to determine which one is best to use as an oral health surveillance tool. The STROBE checklist was used to assist in conducting this research and report the results. It was an observational, analytical, prospective study. A total of 126 water samples were collected at 21 points for six consecutive months and analyzed using electrometric electrode with selective ion and colorimetric technique with SPADNS. The statistical analysis was performed in a descriptive way, followed by the multiple factor ANOVA test and the Student t test for paired samples. The level of significance was set at 5% (p <0.05). The results showed that the electrometric technique showed lower variation (12.3%) when compared to the colorimetric technique (57.4%). The data also show that the two techniques studied demonstrate a reduction in fluoride concentration along the supply network, but this difference was not statistically significant. It can be concluded that the electrometric technique is the best choice to be used by laboratories that perform Vigilance in Oral Health.
Keywords: Fluoretação
Abastecimento de Água
Vigilância Epidemiológica
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ODONTOLOGIA SOCIAL E PREVENTIVA
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Quote: LINS-CANDEIRO, Caio Luiz. Monitoramento de fluoreto nas águas de abastecimento público: comparação entre a técnica eletrométrica e a colorimétrica. 2018. 26 f. Trabalho de Conclusão de Curso (Graduação em Odontologia) – Universidade Federal de Uberlândia, Uberlândia, 2018.
URI: https://repositorio.ufu.br/handle/123456789/23134
Date of defense: 9-Nov-2018
Appears in Collections:TCC - Odontologia

Files in This Item:
File Description SizeFormat 
Monitoramentofluoretoáguasabastecimentopúblico.pdfTCC2.17 MBAdobe PDFThumbnail
View/Open