Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/22879
Document type: Tese
Access type: Acesso Aberto
Title: Desenvolvimento de métodos simples e rápidos para determinação de fármacos por eletroforese capilar com detecção condutométrica sem contato (CE-C4D)
Alternate title (s): Development of simple and rapid methods for the determination of drugs by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D)
Author: Marra, Mariana Cardoso
First Advisor: Richter, Eduardo Mathias
Second Counselor: Batista, Alex Domingues
First member of the Committee: Coelho, Lúcia Helena Gomes
Second member of the Committee: Blanes, Lucas
Third member of the Committee: Faria, Anízio Marcio de
Fourth member of the Committee: Silva, Sidnei Gonçalves da
Summary: No presente trabalho, a eletroforese capilar com detecção condutométrica sem contato acoplada capacitivamente (CE-C4D) foi usada para o desenvolvimento de métodos rápidos para a determinação de princípios ativos em amostras farmacêuticas. O eletrólito (BGE) composto de 10 mmol L-1 de TRIS e 10 mmol L-1 de TAPS (pH 8,4) foi usado para a análise de formulações farmacêuticas contendo: amoxicilina (AMX) + clavulanato (CLA) + potássio (K). Outro BGE composto de 10 mmol L-1 de ácido bórico ajustado com hidróxido de sódio (pH = 9) foi usado para a análise de amostras farmacêuticas contendo: (a) hidroclorotiazida (HCT) + losartana (LOS) + potássio (K); (b) HCT + atenolol (ATE); (c) HCT + metoprolol (MET); (d) HCT + propranolol (PRO); (e) HCT + valsartana (VAL); (f) HCT + benazepril (BEN); (g) HCT + captopril (CAP); (h) HCT + enalapril (ENA); (i) HCT + lisinopril (LIS); (j) HCT + ramipril (RAM). Todos os métodos analíticos propostos são rápidos com menos de 1 minuto de análise e apresentam baixos desvios padrão relativo em relação as áreas dos picos (<4,6%) e tempos de migração (<1,7%), bem como resoluções adequadas (> 1,3) entre os sinais analíticos de cada espécie. As curvas de calibração para todas as espécies quantificadas apresentaram coeficientes de correlação maiores que 0,995. Os métodos propostos apresentaram os seguintes limites de detecção (LOD / μmol L 1): AMX = 25, CLA = 5, K = 4 (KCLA), HCT = 10, LOS = 3, K = 4 (KLOS), ATE = 3, MET = 4, PRO = 5, VAL = 14, BEN = 5, CAP = 7, ENA = 5, LIS = 5 e RAM = 6. Os resultados obtidos com o método proposto para análise de amostras farmacêuticas comerciais contendo AMX+CLA+K e HCT+LOS+K foram comparadas com os obtidos por HPLC e fotometria de chama (K). Os valores de t calculados (teste t-Student pareado), com nível de confiança de 95%, foram menores que o valor crítico (4,303, n = 3) em todas as análises, o que indica que não houve diferença significativa entre os resultados encontrados com o método proposto e HPLC. Os métodos apresentaram resultados satisfatórios nos testes de recuperação (92% a 106%). Além disso, os métodos são simples, de baixo custo (equipamento e manutenção), geram uma quantidade mínima de resíduos (métodos analíticos verdes) e possuem alta frequência analítica (> 75 injeções h-1).
Abstract: In this work, capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) was used for the development of fast methods for determination of active principles in pharmaceutical samples. The background electrolyte (BGE) composed of 10 mmol L-1 of TRIS and 10 mmol L-1 of TAPS (pH 8.4) was used for the analysis of pharmaceutical formulations containing: amoxicillin (AMX) + clavulanate (CLA) + potassium (K). Another BGE composed of 10 mmol L-1 of boric acid ajusted with sodium hydroxide (pH = 9) was used for the analysis of pharmaceutical samples containing: (a) hydrochlorothiazide (HCT) + losartan (LOS) + potassium (K); (b) HCT + atenolol (ATE); (c) HCT + metoprolol (MET); (d) HCT + propranolol (PRO); (e) HCT + valsartan (VAL); (f) HCT + benazepril (BEN); (g) HCT + captopril (CAP); (h) HCT + enalapril (ENA); (i) HCT + lisinopril (LIS); (j) HCT + ramipril (RAM). All proposed analytical methods are fast with duration less than 1 minute and presented low relative standard deviations in relation to peak area (< 4.6%) and migration times (< 1.7%), as well as adequate resolutions (> 1.3) between the analytical signals of each species. Calibration curves for all quantified species showed correlation coefficients greater than 0.995. The proposed methods showed the following limits of detection (LOD / μmol L 1): AMX = 25, CLA = 5, K = 4 (KCLA), HCT = 10, LOS = 3, K = 4 (KLOS), ATE = 3, MET = 4, PRO = 5, VAL = 14, BEN = 5, CAP = 7, ENA = 5, LIS = 5 and RAM = 6. The results obtained with the proposed method for analysis of commercial pharmaceutical samples containing AMX+CLA+K and HCT+LOS+K were compared with those obtained by HPLC and flame photometry (K). The calculated t-values (paired t-Student test), with confidence level of 95%, were smaller than the critical value (4.303, n = 3) in all the analyses, which indicates that there were no significant differences between the results found with the proposed method and HPLC. The proposed methods presented satisfactory results in the recovery test (92% to 106%). Furthermore, the methods are simple, low cost (equipment and maintenance), generate a minimum amount of waste (green analytical methods), and have a high analytical frequency (> 75 injections h-1).
Keywords: Amoxicilina
Clavulanato de potássio
Hidroclorotiazida
Losartana potássica
Atenolol
Metoprolol
Propranolol
Valsartana
Benazepril
Captopril
Enalapril
Lisinopril
Ramipril
Eletroforese capilar
Detecção condutométrica sem contato acoplada capacitivamente
Fármacos
Análises rápidas
Química
Química analítica
Area (s) of CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Química
Quote: MARRA, Mariana Cardoso. Desenvolvimento de métodos simples e rápidos para determinação de fármacos por eletroforese capilar com detecção condutométrica sem contato (CE-C4D). Tese (Doutorado em Química) - Universidade Federal de Uberlândia, Uberlândia, 2018. DOI http://dx.doi.org/10.14393/ufu.te.2018.8006
Document identifier: http://dx.doi.org/10.14393/ufu.te.2018.806
URI: https://repositorio.ufu.br/handle/123456789/22879
Date of defense: 23-Aug-2018
Appears in Collections:TESE - Química

Files in This Item:
File Description SizeFormat 
DesenvolvimentoMétodosSimplesTese de Doutorado em Química de Mariana Cardoso Marra8.27 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.