Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/22879
Full metadata record
DC FieldValueLanguage
dc.creatorMarra, Mariana Cardoso-
dc.date.accessioned2018-11-19T11:03:04Z-
dc.date.available2018-11-19T11:03:04Z-
dc.date.issued2018-08-23-
dc.identifier.citationMARRA, Mariana Cardoso. Desenvolvimento de métodos simples e rápidos para determinação de fármacos por eletroforese capilar com detecção condutométrica sem contato (CE-C4D). Tese (Doutorado em Química) - Universidade Federal de Uberlândia, Uberlândia, 2018. DOI http://dx.doi.org/10.14393/ufu.te.2018.8006pt_BR
dc.identifier.urihttps://repositorio.ufu.br/handle/123456789/22879-
dc.description.abstractIn this work, capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) was used for the development of fast methods for determination of active principles in pharmaceutical samples. The background electrolyte (BGE) composed of 10 mmol L-1 of TRIS and 10 mmol L-1 of TAPS (pH 8.4) was used for the analysis of pharmaceutical formulations containing: amoxicillin (AMX) + clavulanate (CLA) + potassium (K). Another BGE composed of 10 mmol L-1 of boric acid ajusted with sodium hydroxide (pH = 9) was used for the analysis of pharmaceutical samples containing: (a) hydrochlorothiazide (HCT) + losartan (LOS) + potassium (K); (b) HCT + atenolol (ATE); (c) HCT + metoprolol (MET); (d) HCT + propranolol (PRO); (e) HCT + valsartan (VAL); (f) HCT + benazepril (BEN); (g) HCT + captopril (CAP); (h) HCT + enalapril (ENA); (i) HCT + lisinopril (LIS); (j) HCT + ramipril (RAM). All proposed analytical methods are fast with duration less than 1 minute and presented low relative standard deviations in relation to peak area (< 4.6%) and migration times (< 1.7%), as well as adequate resolutions (> 1.3) between the analytical signals of each species. Calibration curves for all quantified species showed correlation coefficients greater than 0.995. The proposed methods showed the following limits of detection (LOD / μmol L 1): AMX = 25, CLA = 5, K = 4 (KCLA), HCT = 10, LOS = 3, K = 4 (KLOS), ATE = 3, MET = 4, PRO = 5, VAL = 14, BEN = 5, CAP = 7, ENA = 5, LIS = 5 and RAM = 6. The results obtained with the proposed method for analysis of commercial pharmaceutical samples containing AMX+CLA+K and HCT+LOS+K were compared with those obtained by HPLC and flame photometry (K). The calculated t-values (paired t-Student test), with confidence level of 95%, were smaller than the critical value (4.303, n = 3) in all the analyses, which indicates that there were no significant differences between the results found with the proposed method and HPLC. The proposed methods presented satisfactory results in the recovery test (92% to 106%). Furthermore, the methods are simple, low cost (equipment and maintenance), generate a minimum amount of waste (green analytical methods), and have a high analytical frequency (> 75 injections h-1).pt_BR
dc.description.sponsorshipFAPEMIG - Fundação de Amparo a Pesquisa do Estado de Minas Geraispt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal de Uberlândiapt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectAmoxicilinapt_BR
dc.subjectClavulanato de potássiopt_BR
dc.subjectHidroclorotiazidapt_BR
dc.subjectLosartana potássicapt_BR
dc.subjectAtenololpt_BR
dc.subjectMetoprololpt_BR
dc.subjectPropranololpt_BR
dc.subjectValsartanapt_BR
dc.subjectBenazeprilpt_BR
dc.subjectCaptoprilpt_BR
dc.subjectEnalaprilpt_BR
dc.subjectLisinoprilpt_BR
dc.subjectRamiprilpt_BR
dc.subjectEletroforese capilarpt_BR
dc.subjectDetecção condutométrica sem contato acoplada capacitivamentept_BR
dc.subjectFármacospt_BR
dc.subjectAnálises rápidaspt_BR
dc.subjectQuímicapt_BR
dc.subjectQuímica analíticapt_BR
dc.titleDesenvolvimento de métodos simples e rápidos para determinação de fármacos por eletroforese capilar com detecção condutométrica sem contato (CE-C4D)pt_BR
dc.title.alternativeDevelopment of simple and rapid methods for the determination of drugs by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D)pt_BR
dc.typeTesept_BR
dc.contributor.advisor1Richter, Eduardo Mathias-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0310068697989712pt_BR
dc.contributor.advisor2Batista, Alex Domingues-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/0624559066360732pt_BR
dc.contributor.referee1Coelho, Lúcia Helena Gomes-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1860251862423358pt_BR
dc.contributor.referee2Blanes, Lucas-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/9391105530529877pt_BR
dc.contributor.referee3Faria, Anízio Marcio de-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/5710906021234699pt_BR
dc.contributor.referee4Silva, Sidnei Gonçalves da-
dc.contributor.referee4Latteshttp://lattes.cnpq.br/3783557934117122pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/3068456790452348pt_BR
dc.description.degreenameTese (Doutorado)pt_BR
dc.description.resumoNo presente trabalho, a eletroforese capilar com detecção condutométrica sem contato acoplada capacitivamente (CE-C4D) foi usada para o desenvolvimento de métodos rápidos para a determinação de princípios ativos em amostras farmacêuticas. O eletrólito (BGE) composto de 10 mmol L-1 de TRIS e 10 mmol L-1 de TAPS (pH 8,4) foi usado para a análise de formulações farmacêuticas contendo: amoxicilina (AMX) + clavulanato (CLA) + potássio (K). Outro BGE composto de 10 mmol L-1 de ácido bórico ajustado com hidróxido de sódio (pH = 9) foi usado para a análise de amostras farmacêuticas contendo: (a) hidroclorotiazida (HCT) + losartana (LOS) + potássio (K); (b) HCT + atenolol (ATE); (c) HCT + metoprolol (MET); (d) HCT + propranolol (PRO); (e) HCT + valsartana (VAL); (f) HCT + benazepril (BEN); (g) HCT + captopril (CAP); (h) HCT + enalapril (ENA); (i) HCT + lisinopril (LIS); (j) HCT + ramipril (RAM). Todos os métodos analíticos propostos são rápidos com menos de 1 minuto de análise e apresentam baixos desvios padrão relativo em relação as áreas dos picos (<4,6%) e tempos de migração (<1,7%), bem como resoluções adequadas (> 1,3) entre os sinais analíticos de cada espécie. As curvas de calibração para todas as espécies quantificadas apresentaram coeficientes de correlação maiores que 0,995. Os métodos propostos apresentaram os seguintes limites de detecção (LOD / μmol L 1): AMX = 25, CLA = 5, K = 4 (KCLA), HCT = 10, LOS = 3, K = 4 (KLOS), ATE = 3, MET = 4, PRO = 5, VAL = 14, BEN = 5, CAP = 7, ENA = 5, LIS = 5 e RAM = 6. Os resultados obtidos com o método proposto para análise de amostras farmacêuticas comerciais contendo AMX+CLA+K e HCT+LOS+K foram comparadas com os obtidos por HPLC e fotometria de chama (K). Os valores de t calculados (teste t-Student pareado), com nível de confiança de 95%, foram menores que o valor crítico (4,303, n = 3) em todas as análises, o que indica que não houve diferença significativa entre os resultados encontrados com o método proposto e HPLC. Os métodos apresentaram resultados satisfatórios nos testes de recuperação (92% a 106%). Além disso, os métodos são simples, de baixo custo (equipamento e manutenção), geram uma quantidade mínima de resíduos (métodos analíticos verdes) e possuem alta frequência analítica (> 75 injeções h-1).pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.programPrograma de Pós-graduação em Químicapt_BR
dc.sizeorduration158pt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRApt_BR
dc.identifier.doihttp://dx.doi.org/10.14393/ufu.te.2018.806pt_BR
dc.crossref.doibatchidpublicado no crossref antes da rotina xml-
Appears in Collections:TESE - Química

Files in This Item:
File Description SizeFormat 
DesenvolvimentoMétodosSimplesTese de Doutorado em Química de Mariana Cardoso Marra8.27 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.