Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/21671
Document type: Tese
Access type: Acesso Aberto
Title: Estratégias de microextração em fases sólida e líquida para determinação de cobre e cromo em água empregando técnicas eletroanalíticas e espectrométricas
Alternate title (s): Microextraction strategies in solid and liquid phases for determination of copper and chromium in water using electroanalytical and spectrometric techniques
Author: Néri, Thaís de Souza
First Advisor: Coelho, Nivia Maria Melo
First coorientator: Batista, Alex Domingues
First member of the Committee: Nascimento, Angerson Nogueira do
Second member of the Committee: Dornellas, Rafael Machado
Third member of the Committee: Franco, Diego Leoni
Fourth member of the Committee: Trovó, Alam Gustavo
Summary: Um método rápido e sensível foi proposto para a determinação de íons cromato em amostras de água por F AAS combinada com análise por injeção em fluxo, com a pré-concentração em linha utilizando uma minicoluna. Os íons cromato nas amostras foi retido na minicoluna preenchida com hidróxido duplo lamelar (HDL) e, em seguida, foi eluído com Na2CO3 0,1 mol L-1 a uma vazão de 0,5 mL min-1 diretamente no F AAS. O adsorvente foi caracterizado por espectroscopia de infravermelho médio (MIR), microscopia eletrônica de varredura (MEV) e BET (Brunauer, Emmett, Teller). A pré-concentração foi promovida através da interação entre o íon cromato e o material HDL nas suas duplas camadas. Algumas variáveis que influenciam a extração de íons metálicos foram estudadas. Sob condições otimizadas, o método apresentou fatores de enriquecimento de 44,53, o desvio padrão relativo (RSD) foi de 4,7 %, o limite de detecção de 1,42 μg L−1 e linearidade de 5,0-200,0 μg L−1. A verificação da exatidão foi realizada através da análise de um material de referência certificado para água (APS-1071 NIST).
Abstract: A rapid and essential example for the analysis of chromate ions in water samples is combined analysis with flow injection, with an in-line preconcentration as a minicolumn. The chromate ions in the samples were retained in the double-lamellar hydroxide filled (LDH) minicolon and then eluted with 0.1 mol L-1 Na2CO3 at a flow rate of 0.5 mL min-1 directly into the F AAS. The adsorbent was characterized by medium infrared spectroscopy (MIR), scanning electron microscopy (SEM) and BET (Brunauer, Emmett, Teller). The preconcentration was promoted through the interaction between the ion chromate and the HDL material in its double layers. Some variables that influence the extraction of metallic ions were studied. Under optimized conditions, the method presented enrichment factors of 44.53, the relative standard deviation (RSD) was 4.7%, the detection limit of 1.42 μg L-1 and linearity of 5.0-200, 0 μg L-1. The verification of accuracy was performed through the analysis of a certified reference material for water (APS-1071 NIST).
Keywords: Química
Cromo
Espectrometria de Absorção atômica
Análise por injeção de fluxo
Pré-concentração
Hidróxido duplo lamelar
Espectrometria de Absorção atômica com chama
Chromium
Preconcentration
Lamellar Double Hydroxide
Flow Injection System
Flame Atomic Absorption Spectrometry
Area (s) of CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Química
Quote: NÉRI, Thaís de Souza. Estratégias de microextração em fases sólida e líquida para determinação de cobre e cromo em água empregando técnicas eletroanalíticas e espectrométricas. 2018. 147 f. Tese (Doutorado em Química) - Universidade Federal de Uberlândia, Uberlândia, 2018. DOI http://dx.doi.org/10.14393/ufu.te.2018.780.
Document identifier: http://dx.doi.org/10.14393/ufu.te.2018.780
URI: https://repositorio.ufu.br/handle/123456789/21671
Date of defense: 16-Mar-2018
Appears in Collections:TESE - Química

Files in This Item:
File Description SizeFormat 
EstrategiasMicroextracaoFases.pdfTese4.29 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.