Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/18178
Document type: Dissertação
Access type: Acesso Aberto
Title: Avaliação retrospectiva de próteses implantosuportadas à base de Zircônia obtidas por sistema CAD/CAM
Author: Mazão, Julia Dantas
First Advisor: Prado, Célio Jesus do
First member of the Committee: Raposo, Luiz Henrique Araújo
Second member of the Committee: Ribeiro, Ricardo Faria
Summary: Objetivos: O objetivo deste estudo retrospectivo foi avaliar a taxa de sucesso e a influência de fatores técnicos, biológicos e oclusais, na sobrevida de próteses sobre implantes confeccionadas em zircônia, pelo sistema CAD / CAM Zirkonzahn. Materiais e Métodos: Dois pesquisadores experientes em próteses avaliaram todas as próteses. Os pacientes foram avaliados segundo: as características das próteses; avaliação oclusal; avaliação biológica; avaliação técnica, avaliação radiográfica e o índice de satisfação com o tratamento. O teste de Kaplan-Meier foi utilizado para estimar a taxa de sobrevivência a partir dos dados de sobrevida da prótese. Resultados: Foram avaliados 32 pacientes, que foram tratados com 90 próteses sobre implantes confeccionadas em zircônia por meio do sistema CAD/CAM Zirkonzahn. Entre as próteses analisadas, havia casos unitários, parciais e totais. O período de observação médio foi de 33.04  5,7 meses. A taxa de sobrevivência de Kaplan Meier foi de 90,9% para próteses unitárias, 84,9% para próteses parciais e 100% para próteses totais. As complicações mais comuns foram desaperto do parafuso, desadaptação marginal e fratura da infraestrutura. A satisfação geral dos pacientes com o tratamento foi de 8,1 (± 2,1). Conclusão: A forma de tratamento avaliada é uma opção adequada, porém o excessivo índice de desaperto de parafusos, as desadaptações marginais bem como as fraturas de bordo, principalmente nas próteses não segmentadas, mostram que melhorias devem ser feitas com a finalidade de minimizar os problemas encontrados.
Abstract: Objectives: The aim of this retrospective study was to evaluate the survival rate and the influence of technical, biological and occlusal factors at implantsupported zirconia restorations obtained by CAD/CAM system. Methods: Two experience prosthodontics researchers working in pairs analyzed and rated all patients. The patients were evaluated according to the characteristics of the restorations; occlusal evaluation; biological evaluation; technical evaluation; radiographic evaluation and the satisfaction index with the treatment. The Kaplan-Meier test was used to estimate the survival rate from the prosthesis survival data. Results: A total of 32 patients and 90 implant-supported zirconia restorations obtained by CAD/CAM system were evaluated, after a mean observation period of 33.045.7 months. The Kaplan Meier survival rate was 90.9% for single, 84.9% for FPD restorations and 100% for complete-arch implant-supported restorations. The most common complications were screw loosening, lack of marginal adaptation and framework fracture. The overall patients’ satisfaction with the treatment was 8.1 (±2,1). Conclusion: The evaluated treatment is an adequate option to metal-free prostheses, however the excessive index of screw loosening, lack of marginal adaptation as well as border fractures, especially in the non-segmented prostheses, shows that improvements must be made in order to minimize the problems encountered
Keywords: Odontologia
Implantes dentários
Prótese dentária
Sistema CAD/CAM
Zircônia
Estudo retrospectivo
CAD/CAM
Próteses implantadas
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
Language: por
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Odontologia
Quote: MAZÃO, Julia Dantas. Avaliação retrospectiva de próteses implantosuportadas à base de Zircônia obtidas por sistema CAD/CAM. 2017. 66 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2017.
Document identifier: ufu.http://dx.doi.org/10.14393/ufu.di.2017.139
URI: https://repositorio.ufu.br/handle/123456789/18178
Date of defense: 8-Feb-2017
Appears in Collections:DISSERTAÇÃO - Odontologia

Files in This Item:
File Description SizeFormat 
AvaliacaoRetrospectivaProteses.pdfDissertação6.31 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.