Use este identificador para citar ou linkar para este item:
https://repositorio.ufu.br/handle/123456789/15020| Tipo do documento: | Dissertação |
| Tipo de acesso: | Acesso Aberto |
| Título: | Características funcionais de implantes dentários: topografia superficial e molhabilidade |
| Título(s) alternativo(s): | Functional characteristics of dental implants: surface topography and wettability |
| Autor(es): | Barbosa, Tarsis Prado |
| Primeiro orientador: | Costa, Henara Lillian |
| Primeiro membro da banca: | Mello, José Daniel Biasoli de |
| Segundo membro da banca: | Godoy, Geralda Cristina Durães de |
| Resumo: | Os implantes dentários são submetidos a diferentes biosistemas, de forma que o desempenho biológico destes componentes depende da interação entre o material do implante e o sistema vivo. Três características da superfície dos biomateriais utilizados nos implantes são tidas como relevantes no processo de formação óssea: composição química, energia da superfície e topografia. O ótimo desempenho dos implantes de titânio em geral é relacionado à sua camada passiva de óxido que imita a natureza cerâmica do osso. A rugosidade da superfície possui influência na migração e proliferação celular sendo que muitas avaliações demonstraram que implantes com superfície rugosa possuem melhor aposição óssea e contato osso-implante que implantes com superfícies lisas. A energia livre de superfície está relacionada a molhabilidade e pode influenciar o nível de interação do implante com o corpo. Porém, ainda é preciso uma melhor compreensão deste fenômeno e a forma como ele afeta o ambiente biológico circundante. O objetivo deste estudo foi caracterizar a topografia e a energia de superfície de dois tipos de implantes e discos de titânio produzidos com os seguintes tratamentos: duplo ataque ácido e duplo ataque ácido seguido de deposição de hidroxiapatita nanométrica. Para caracterizar a topografia da superfície foi utilizada interferometria a laser e MEV. Uma nova metodologia de utilização da interferometria a laser para a medição da superfície de implantes dentários com ângulos internos de rosca maiores que 70º foi sugerida. Para a caracterização da energia de superfície nos discos foram utilizados os métodos da gota séssil estático e dinâmico. Dois novos métodos foram propostos para caracterizar a energia da superfície dos implantes em si: um método qualitativo relacionado ao fenômeno da capilaridade e um método de imersão e emersão dos implantes em 3 líquidos diferentes. Verificou-se que nestes modelos de implantes a topografia dos flancos da rosca (83% da área superficial que estará em contato com o meio vivo) não pode ser extrapolada pela topografia dos discos. Os resultados obtidos na caracterização da energia da superfície pelos novos métodos propostos foram compatíveis com os resultados obtidos pelos métodos da gota séssil estático e dinâmico. Não observou-se diferença de energia livre entre os dois modelos de implantes estudados. |
| Abstract: | Dental implants are subjected to different biosystems, so the biological performance of these components depends on the interaction between the implant material and the living system. Three surface characteristics of biomaterials used in the implants are regarded as relevant in the process of bone formation: chemical composition, surface energy and topography. In general, optimum performance of titanium implants is related to its passive oxide layer that mimics the bone ceramic nature. The surface roughness has influence on cell migration and proliferation and many studies show that implants with a rough surface have better bone apposition and bone-implant contact than implants with smooth surfaces. The surface free energy is related to wettability and may influence the level of implant interaction with the body. However, we still need a better understanding of this phenomenon and how it affects the surrounding biological environment. The objective of this study was to characterize the topography and the surface energy of two kinds of titanium implants and discs produced with the following treatments: double etching and double etching with nanometric hydroxyapatite deposition. To characterize the surface topography was used laser interferometry and SEM. A new method of using laser interferometry to measure the surface of dental implants with threaded interior angles larger than 70 ° is suggested. To characterize the discs surface energy, the dynamic and static sessile drop methods were used. Two new methods were proposed to characterize the surface energy of the implant itself: a qualitative method related to the phenomenon of capillarity and an immersion and emersion method of the implants in 3 different liquids. It was found in these implants types that the topography of the thread flanks (83% of the surface area that will be in contact with the living environment) can not be extrapolated through the topography of the discs. The results obtained in the characterization of the surface energy by the new methods proposed were consistent with the results obtained by the static and dynamic sessile drop methods. It was not observed free energy difference between the two implants studied. |
| Palavras-chave: | Implantes Topografia de superfície Rugosidade Molhabilidade Energia livre Implants Superficial topography Roughness Wetting Free energy Implantes dentários Aspereza de superfície |
| Área(s) do CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA MECANICA |
| Idioma: | por |
| País: | BR |
| Editora: | Universidade Federal de Uberlândia |
| Sigla da instituição: | UFU |
| Departamento: | Engenharias |
| Programa: | Programa de Pós-graduação em Engenharia Mecânica |
| Referência: | BARBOSA, Tarsis Prado. Functional characteristics of dental implants: surface topography and wettability. 2016. 108 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2016. DOI http://doi.org/10.14393/ufu.di.2016.280 |
| Identificador do documento: | http://doi.org/10.14393/ufu.di.2016.280 |
| URI: | https://repositorio.ufu.br/handle/123456789/15020 |
| Data de defesa: | 29-Mar-2016 |
| Aparece nas coleções: | DISSERTAÇÃO - Engenharia Mecânica |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| CaracteristicasFuncionaisImplantes.pdf | 4.39 MB | Adobe PDF | ![]() Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.
