Please use this identifier to cite or link to this item:
https://repositorio.ufu.br/handle/123456789/14237
Document type: | Dissertação |
Access type: | Acesso Aberto |
Title: | Análise da micromedição do volume de água potável domiciliar e sua influência no cálculo das perdas no sistema de distribuição |
Alternate title (s): | Micro-measurement of domestic drinking water volume and its influence on the calculation of losses in the distribution system |
Author: | Borges, Elsio Júnior Bonati |
First Advisor: | Arruda, Laerte Bernardes |
First member of the Committee: | Alamy Filho, José Eduardo |
Second member of the Committee: | Prado, Racine Tadeu Araujo |
Summary: | A acelerada degradação dos recursos hídricos naturais, juntamente com a crescente demanda por água potável, faz com que programas de combate às perdas desse bem essencial se tornem cada vez mais indispensáveis aos gestores ambientais. Este trabalho está inserido nesse contexto, com o objetivo de avaliar a magnitude do erro de medição do parque de hidrômetros instalados na cidade de Uberlândia-MG, quando sujeitos às variações de demanda. Nesse sentido, buscou-se comparar o equipamento comumente utilizado com sistemas mais sensíveis à medição de baixas vazões, para verificar a confiabilidade da micromedição realizada e servir como subsídio para o cálculo dos indicadores de perdas. A avaliação mostrou que o aparelho com maior sensibilidade totalizou, em média, um volume 13,56% superior ao do hidrômetro normalmente utilizado. |
Abstract: | The accelerated degradation of natural hydric resources, along with the increasing demand for drinking water, urge for programs which deal with the losses of this essential good, and that are essential for environmental managers. This work is inserted in this context, with the objective of evaluating the magnitude of the measurement error of the hydrometers installed in Uberlândia-MG, when subjected to consumption variations. There have been comparisons of the equipment commonly used with systems that are more sensible to the measurement of low flows, in order to verify the reliability of the micro-measurement accomplished and serve as subsidy for the calculation of the indicators of losses. The evaluation showed that the equipment with larger sensibility totaled, on average, a volume 13.56% higher than the more commonly used hydrometer. |
Keywords: | Perdas de água Medição de água Micromedição Hidrômetro Water losses Water measurement Micro-measurement Hydrometer Abastecimento de água |
Area (s) of CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA CIVIL |
Language: | por |
Country: | BR |
Publisher: | Universidade Federal de Uberlândia |
Institution Acronym: | UFU |
Department: | Engenharias |
Program: | Programa de Pós-graduação em Engenharia Civil |
Quote: | BORGES, Elsio Júnior Bonati. Micro-measurement of domestic drinking water volume and its influence on the calculation of losses in the distribution system. 2007. 103 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2007. |
URI: | https://repositorio.ufu.br/handle/123456789/14237 |
Date of defense: | 29-Aug-2007 |
Appears in Collections: | DISSERTAÇÃO - Engenharia Civil |