Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/47680
ORCID:  http://orcid.org/0000-0001-9746-9312
Tipo de documento: Tese
Tipo de acceso: Acesso Aberto
Título: Avaliação da incerteza associada à tenacidade à fratura obtida via indentação instrumentada
Título (s) alternativo (s): Assessment of uncertainty associated with fracture toughness obtained via instrumented indentation
Autor: Souza, Cláudio Costa
Primer orientador: Arencibia, Rosenda Valdés
Primer coorientador: Bose Filho, Waldek Wladimir
Primer miembro de la banca: Silva, Marcio Bacci da
Segundo miembro de la banca: Silva Júnior, Washington Martins da
Tercer miembro de la banca: Piratelli Filho, Antonio
Cuarto miembro de la banca: Oliveira, Marcelo Falcão de
Resumen: Este trabalho tem como objetivo avaliar a incerteza associada à tenacidade à fratura do aço 4130 M obtida a partir de ensaios de indentação instrumentada. Três diferentes metodologias para a obtenção da tenacidade à fratura foram consideradas, a saber: Lee et al. (2006), Zhang, Wang e Wang (2019) e Yu et al. (2023). Neste estudo, as incertezas foram calculadas pelo método do Guia para Expressão da Incerteza de Medição (GUM) e pelo método de Monte Carlo. Para a avaliação da incerteza, todos os mensurandos e variáveis de entrada foram identificados com base nas equações propostas por estes autores. Em seguida, a incerteza padrão associada a cada variável de entrada foi calculada aplicando o método GUM. Para quantificar as incertezas das variáveis cujas equações eram complexas, foi utilizado o método de Monte Carlo. As incertezas expandidas relativas à tenacidade à fratura foram de 4,94, 7,52 e 19,97 MPa∙m0,5 considerando as metodologias de Lee et al. (2006), Zhang, Wang e Wang (2019a) e Yu et al. (2023), respectivamente, para um nível de abrangência de 95,45 % e fator k = 2,00. Apesar da incerteza da metodologia de Yu et al. (2023) ter sido a maior dentre as três avaliadas, o valor da tenacidade à fratura para esta metodologia foi o mais próximo do valor de referência estimado por Melo (2019), com menos de 2 % de diferença. Já a metodologia de Lee et al. (2006) apresentou uma diferença no valor de tenacidade de aproximadamente 23 % em relação ao valor de referência. O teste estatístico de Mann-Whitney indicou que apenas a metodologia de Yu et al. (2023) fornece valores estatisticamente iguais aos obtidos por Melo (2019), para um nível de abrangência de 95 %.
Abstract: This work aims to evaluate the uncertainty associated with the fracture toughness of 4130 M steel obtained from instrumented indentation tests. Three different methodologies for obtaining fracture toughness were considered: Lee et al. (2006), Zhang, Wang, and Wang (2019), and Yu et al. (2023). In this study, uncertainties were calculated using the Guide to the Expression of Uncertainty in Measurement (GUM) method and the Monte Carlo method. For uncertainty assessment, all measurands and input variables were identified based on the equations proposed by these authors. Then, the standard uncertainty associated with each input variable was calculated using the GUM method. To quantify the uncertainties of variables with complex equations, the Monte Carlo method was used. The expanded uncertainties related to fracture toughness were 4.94, 7.52, and 19.97 MPa∙m0.5 considering the methodologies of Lee et al. (2006), Zhang, Wang and Wang (2019a) and Yu et al. (2023), respectively, for a coverage level of 95.45 % and k factor = 2.00. Although the uncertainty of the Yu et al. (2023) methodology was the largest among the three evaluated, the fracture toughness value for this methodology was the closest to the reference value estimated by Melo (2019), with less than 2 % difference. The Lee et al. (2006) methodology presented a difference in the toughness value of approximately 23 % in relation to the reference value. The Mann-Whitney statistical test indicated that only the methodology of Yu et al. (2023) provides values statistically equal to those obtained by Melo (2019), for a coverage level of 95 %.
Palabras clave: Incerteza de medição
Método GUM
Método de Monte Carlo
Tenacidade à fratura
Indentação instrumentada
Measurement uncertainty
GUM method
Monte Carlo method
Fracture Toughness
Instrumented indentation
Área (s) del CNPq: CNPQ::ENGENHARIAS::ENGENHARIA MECANICA::PROCESSOS DE FABRICACAO
Tema: Engenharia mecânica
Processos de fabricação
Persistência
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Engenharia Mecânica
Cita: SOUZA, Cláudio Costa. Avaliação da incerteza associada à tenacidade à fratura obtida via indentação instrumentada. 2025. 265 f. Tese (Doutorado em Engenharia Mecânica) - Universidade Federal de Uberlândia, Uberlândia, 2025. DOI http://doi.org/10.14393/ufu.te.2025.606.
Identificador del documento: http://doi.org/10.14393/ufu.te.2025.606
URI: https://repositorio.ufu.br/handle/123456789/47680
Fecha de defensa: 8-oct-2025
Objetivos de Desarrollo Sostenible (ODS): ODS::ODS 9. Indústria, Inovação e infraestrutura - Construir infraestrutura resiliente, promover a industrialização inclusiva e sustentável, e fomentar a inovação.
Aparece en las colecciones:TESE - Engenharia Mecânica

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
AvaliacaoIncertezaAssociada.pdfTese9.68 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons