Use este identificador para citar ou linkar para este item: https://repositorio.ufu.br/handle/123456789/47378
ORCID:  http://orcid.org/0000-0001-5600-3858
Tipo do documento: Tese
Tipo de acesso: Acesso Aberto
Título: Impressão 3D aplicada à eletroanálise: manufatura de célula eletroquímica, filamento condutor e aplicação no meio ambiente.
Título(s) alternativo(s): 3D printing applied to electroanalysis: Manufacturing of electrochemical cell, conductive filament and application in the environment.
Autor(es): Ramos, David Luiz Oliveira
Primeiro orientador: Richter, Eduardo Mathias
Primeiro coorientador: Munoz, Rodrigo Alejandro Abarza
Primeiro membro da banca: Nossol, Edson
Segundo membro da banca: Silva, Rodrigo Amorim Bezerra da
Terceiro membro da banca: Silva, Iranaldo Santos da
Quarto membro da banca: Dornellas, Rafael Machado
Resumo: Neste trabalho, primeiramente é apresentada uma nova célula eletroquímica descartável que permite análise de pequenos volumes (50 a 2000 µL) e consiste em apenas duas partes totalmente impressas que permitem fácil acoplamento de diferentes materiais como eletrodo de trabalho, referência e auxiliar. Como prova de conceito, paracetamol, cocaína e ácido úrico foram usados como analitos modelo usando diferentes materiais como eletrodo de trabalho. Curvas de calibração lineares (r > 0,99) com inclinações semelhantes (0,29 ± 0,01 μA μmol L-1; DPR = 3,4%) foram obtidas por voltametria de onda quadrada para análise de diferentes volumes de soluções padrão de paracetamol (50, 100 e 200 μL). Para o ácido úrico, uma faixa linear de 10–125 μmol L-1 (r > 0,99), foi obtida usando voltametria de pulso diferencial como técnica eletroquímica e uma base de grafeno induzida por laser como eletrodo de trabalho. Com o acoplamento de eletrodo de trabalho de diamante dopado com boro (BDD), testes de triagem foram realizados com sucesso em amostras de cocaína com detecção seletiva de cocaína na presença de seus adulterantes mais comuns, com uma recuperação de 103 ± 4%. Na segunda parte foi proposto o desenvolvimento de um filamento com uma grande carga condutora, que ao mesmo tempo mantivesse boa capacidade de impressão. A composição estudada consistiu em carbon black como material condutor e polipropileno como material termoplástico. Foi obtido um filamento com a composição de 40% de carbon black e 60% de polipropileno e a partir da técnica de voltametria de onda quadrada, utilizando eletrodos impressos a partir deste filamento como eletrodo de trabalho, foi realizada a determinação de colchicina em amostras de água de torneira, garrafa e rio. O método analítico apresentou uma faixa linear de resposta entre 2 e 50 µmol L-1, um LD igual a 10 nmol L-1 e recuperações acima de 90%, enquanto o método de pré-concentração apresentou um fator de 130.
Abstract: In this work, we first present a novel disposable electrochemical cell designed for the analysis of small volumes (50 to 2000 µL). The cell consists of only two fully 3D-printed components, allowing for easy integration of various materials as the working, reference, and auxiliary electrodes. As a proof of concept, paracetamol, cocaine, and uric acid were used as model analytes, with different materials employed as the working electrode. Linear calibration curves (R2 > 0.99) with similar slopes (0.29 ± 0.01 μA μmol L⁻¹; RSD = 3.4%) were obtained using square wave voltammetry for different volumes of paracetamol standard solutions (50, 100, and 200 μL). For uric acid, a linear range of 10–125 μmol L⁻¹ (R2 > 0.99) was achieved using differential pulse voltammetry and a laser-induced graphene-based electrode as the working electrode. When a boron-doped diamond working electrode was used, successful screening tests were conducted on cocaine samples, enabling selective detection of cocaine in the presence of common adulterants, with a recovery rate of 103 ± 4%. In the second part of the study, we proposed the development of a filament with a high conductive load while maintaining good printability. The composition studied consisted of carbon black as the conductive material and polypropylene as the thermoplastic. A filament with a composition of 40% carbon black and 60% polypropylene was obtained. Using square-wave voltammetry, using electrodes printed from this filament as the working electrode, colchicine was determined in tap, bottle, and river water samples. The analytical method showed a linear response range between 2 and 50 µmol L-1, an LD of 10 nmol L-1, and recoveries above 90%, while the preconcentration method showed a factor of 130.
Palavras-chave: Portabilidade
Portability
Manufatura aditiva
Additive manufacturing
Impressão 3D
3D printing
Rletrodo impresso
Printed electrode
Eletroanálise
Electroanalysis
Amostra ambiental
Environmental sample
Área(s) do CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::ELETROANALITICA
Assunto: Análise eletroquímica - impressão 3d
Química
Célula eletroquímicas
Eletrodo
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Química
Referência: RAMOS, David Luiz Oliveira. Impressão 3D aplicada à eletroanálise: manufatura de célula eletroquímica, filamento condutor e aplicação no meio ambiente. 2025. 116 f. Tese (Doutorado em Química) - Universidade Federal de Uberlândia, Uberlândia, 2025. http://doi.org/10.14393/ufu.te.2025.605
Identificador do documento: http://doi.org/10.14393/ufu.te.2025.605
URI: https://repositorio.ufu.br/handle/123456789/47378
Data de defesa: 26-Set-2025
Objetivos de Desenvolvimento Sustentável (ODS): ODS::ODS 9. Indústria, Inovação e infraestrutura - Construir infraestrutura resiliente, promover a industrialização inclusiva e sustentável, e fomentar a inovação.
Aparece nas coleções:TESE - Química

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Impressão3DAplicadaEletroanálise.pdf9.78 MBAdobe PDFThumbnail
Visualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons