Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/46223
Document type: Dissertação
Access type: Acesso Aberto
Title: Avaliação da expressão de artefatos de imagem de diferentes compostos biocerâmicos em tomografia computadorizada de feixe cônico
Alternate title (s): Evaluation of the expression of imaging artifacts of different bioceramic compounds in cone beam computed tomography
Author: Morábito, Caio Rodrigo de Oliveira
First Advisor: Barbosa, Gabriella Lopes de Rezende
First member of the Committee: Rosatto, Camila Maria Peres de
Second member of the Committee: Silva, Karla Rovaris da
Summary: The objective of this study was to evaluate the expression of tomographic artifacts promoted by bioceramic endodontic materials. To carry out this study, a homogeneous acrylic phantom with a central cylindrical opening was manufactured to allow the insertion and accommodation of the materials. The groups in this study were assigned according to the material used to fill out the phantom (n=4): a. Control group without material, b. BIO-C ®Repair, c. Biodentine and d. MTA White. Three tomographic images of each phantom were captured using a Gendex CB-500 cone beam computed tomography (CBCT) (Gendex Dental Systems, Hatfield, PA, USA) using the following acquisition parameters: 120 kV, 5 mA, FOV of 8.5x6 cm, and voxel of 0.2 mm. The axial reconstructions used for analysis were manually selected and the point of choice was the center of the total reconstruction. In each chosen axial image, a region of interest (ROI) was selected, covering the entire material. Additionally, eight ROI with identical dimensions were positioned around the central region. The average standard deviation of the gray scale values for each material was calculated by aggregating the standard deviation values of the eight ROI. Higher. The mean standard deviation of the grayscale values for each material was calculated by aggregating the standard deviation values of the eight ROIs. A higher level of artifacts associated with Bio C Repair and MTA materials was observed than the Control and Biodentine groups (p<0.05). A higher level of artifacts was also observed in the Biodentine group compared to the Control group (p<0.05). This study demonstrated that the Biodentine material produced a more homogeneous and better quality CBCT image than the other materials tested, which was represented by the expression of fewer artifacts in the image.
Abstract: The objective of this study was to evaluate the expression of tomographic artifacts promoted by bioceramic endodontic materials. To carry out this study, a homogeneous acrylic phantom with a central cylindrical opening was manufactured to allow the insertion and accommodation of the materials. The groups in this study were assigned according to the material used to fill out the phantom (n=4): a. Control group without material, b. BIO-C ®Repair, c. Biodentine and d. MTA White. Three tomographic images of each phantom were captured using a Gendex CB-500 cone beam computed tomography (CBCT) (Gendex Dental Systems, Hatfield, PA, USA) using the following acquisition parameters: 120 kV, 5 mA, FOV of 8.5x6 cm, and voxel of 0.2 mm. The axial reconstructions used for analysis were manually selected and the point of choice was the center of the total reconstruction. In each chosen axial image, a region of interest (ROI) was selected, covering the entire material. Additionally, eight ROI with identical dimensions were positioned around the central region. The average standard deviation of the gray scale values for each material was calculated by aggregating the standard deviation values of the eight ROI. Higher. The mean standard deviation of the grayscale values for each material was calculated by aggregating the standard deviation values of the eight ROIs. A higher level of artifacts associated with Bio C Repair and MTA materials was observed than the Control and Biodentine groups (p<0.05). A higher level of artifacts was also observed in the Biodentine group compared to the Control group (p<0.05). This study demonstrated that the Biodentine material produced a more homogeneous and better quality CBCT image than the other materials tested, which was represented by the expression of fewer artifacts in the image.
Keywords: Artefatos
Artifacts
Endodontia
Tomografia Computadorizada de Feixe Cônico
Endodontics
Predictability
Cone Beam Computed Tomography
Previsibilidade
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::RADIOLOGIA ODONTOLOGICA
Subject: Odontologia
Tomografia computadorizada de feixe cônico
Diagnóstico por imagem
Language: eng
Country: Brasil
Publisher: Universidade Federal de Uberlândia
Program: Programa de Pós-graduação em Odontologia
Quote: MORÁBITO, Caio Rodrigo de Oliveira. Avaliação da expressão de artefatos de imagem de diferentes compostos biocerâmicos em tomografia computadorizada de feixe cônico. 2024. 15 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2025.DOI http://doi.org/10.14393/ufu.di.2024.518.
Document identifier: http://doi.org/10.14393/ufu.di.2024.518
URI: https://repositorio.ufu.br/handle/123456789/46223
Date of defense: 2-Aug-2024
Sustainable Development Goals SDGs: ODS::ODS 3. Saúde e bem-estar - Assegurar uma vida saudável e promover o bem-estar para todos, em todas as idades.
Appears in Collections:DISSERTAÇÃO - Odontologia

Files in This Item:
File Description SizeFormat 
AvaliaçãoExpressãoArtefatos.pdfDissertação466.75 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons