Please use this identifier to cite or link to this item:
https://repositorio.ufu.br/handle/123456789/43743
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Resende, Ênio Costa | - |
dc.date.accessioned | 2024-10-30T18:11:53Z | - |
dc.date.available | 2024-10-30T18:11:53Z | - |
dc.date.issued | 2024-10-25 | - |
dc.identifier.citation | RESENDE, Ênio Costa. Anti-islanding algorithm based on active phase jump with positive feedback and intermittent perturbation for integration of inverter-based distributed energy resources to the electric power system. 2024. 160 f. Tese (Doutorado em Engenharia Elétrica) - Universidade Federal de Uberlândia, Uberlândia, 2024. DOI http://doi.org/10.14393/ufu.te.2024.712. | pt_BR |
dc.identifier.uri | https://repositorio.ufu.br/handle/123456789/43743 | - |
dc.description.abstract | The growing penetration of Distributed Generation Systems (DGS) based on renewable resources into the distribution utility grid paves the way for a new energy generation and for an electrical consumption paradigm founded on the gradual replacing of fossil fuels by clean power generation. However, in spite of all its benefits, the adoption of the DGS brings new problems and challenges that must be addressed by the academical research. One of the main security issues is the unintentional islanding. Defined as the loss of the connection with the main grid, the unintentional islanding phenomenon can lead to the increasing of the harmonic pollution of the grid, electrical accidents with maintenance workers and out-of-phase reclosures. The purpose of this work is to present a new Anti-Islanding Protection (AIP) algorithm, based on the insertion of a phase jump at the beginning of each half cycle of the inverter output current. This phase jump will be parametrized with a positive frequency feedback in order to improve the algorithm performance by linking the frequency error with the inserted disturbance. Futhermore, the new AIP scheme defines maximum and minimum frequency alarm thresholds that, when reached, trip an additional phase jump to improve islanding detection, reducing the detection time and mitigating the Non-Detection Zone (NDZ) without demanding extra current harmonic degradation. Beyond this, the work also performs a complete review of the islanding theory, addressing the NDZ concept and its mapping technologies and conducting a critical analysis of the already existing solutions, highlighting the evolution timeline of each algorithm. Finally, in order to attest the new solution effectivity, it will be also carried out a comparative study with other already known AIP methods: Active Frequency Drift (AFD), AFD by (CHEN et al., 2013), AFD with Pulsating Chopping Factor (AFDPCF), Sandia Frequency Shift (SFS) and the Active Phase Jump with Positive Feedback (APJPF). The test methodology will be based on the most restrictive Standards recommendations and the results will be categorized according to three Key Parameter Indicators (KPI): detection time, NDZ and THDi. The obtained results show that the proposed scheme reached the mitigation of the NDZ and accomplished the fastest islanding detection for all of the tested cases. | pt_BR |
dc.description.sponsorship | CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior | pt_BR |
dc.language | eng | pt_BR |
dc.publisher | Universidade Federal de Uberlândia | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Anti-Ilhamento | pt_BR |
dc.subject | Anti-Islanding | pt_BR |
dc.subject | Geração Distribuída | pt_BR |
dc.subject | Distributed Generation | pt_BR |
dc.subject | Sistemas Fotovoltaicos Conectados à Rede | pt_BR |
dc.subject | Grid Tied Photovoltaic Systems | pt_BR |
dc.subject | Zona de Não Detecção | pt_BR |
dc.subject | Non-Detection Zone | pt_BR |
dc.subject | Tempo de Detecção | pt_BR |
dc.subject | Detection Time | pt_BR |
dc.title | Anti-islanding algorithm based on active phase jump with positive feedback and intermittent perturbation for integration of inverter-based distributed energy resources to the electric power system. | pt_BR |
dc.title.alternative | Algoritmo anti-ilhamento baseado em salto de fase ativo com feedback positivo e perturbação intermitente para integração de recursos energéticos distribuídos baseados em inversor ao sistema elétrico | pt_BR |
dc.type | Tese | pt_BR |
dc.contributor.advisor-co1 | Simões, Marcelo Godoy | - |
dc.contributor.advisor-co1Lattes | http://lattes.cnpq.br/0936764457718012 | pt_BR |
dc.contributor.advisor1 | Freitas, Luiz Carlos Gomes de | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/0855458644750836 | pt_BR |
dc.contributor.referee1 | Lima, Gustavo Brito de | - |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/3547526218965223 | pt_BR |
dc.contributor.referee2 | Busarello, Tiago Davi Curi | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/9413842904460527 | pt_BR |
dc.contributor.referee3 | Coelho, Ernane Antonio Alves | - |
dc.contributor.referee3Lattes | http://lattes.cnpq.br/9183492978798433 | pt_BR |
dc.contributor.referee4 | Melo, Fernando Cardoso | - |
dc.contributor.referee4Lattes | http://lattes.cnpq.br/8679854811298510 | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/5746130890920475 | pt_BR |
dc.description.degreename | Tese (Doutorado) | pt_BR |
dc.description.resumo | A crescente penetração dos Sistemas de Geração Distribuída (SGD) baseados em recursos renováveis na rede de distribuição de utilidade pública abre caminho para um novo paradigma de geração de energia e consumo elétrico, fundamentado na substituição gradual dos combustíveis fósseis por geração de energia limpa. No entanto, apesar de todos os seus benefícios, a adoção dos SGD traz novos problemas e desafios que devem ser abordados pela pesquisa acadêmica. Um dos principais problemas de segurança é a ilha não intencional. Definido como a perda da conexão com a rede principal, o fenômeno de ilha não intencional pode levar ao aumento ou à poluição harmônica da rede, acidentes elétricos com trabalhadores de manutenção e religamentos fora de fase. O objetivo deste trabalho é apresentar um novo algoritmo de Proteção Anti-Ilhamento (PAI), baseado na inserção de um salto de fase no início de cada meia onda da corrente de saída do inversor. Esse salto de fase será parametrizado com um feedback positivo de frequência para melhorar o desempenho do algoritmo, ligando o erro de frequência à perturbação inserida. Além disso, o novo esquema de PAI define limites máximos e mínimos de alarme de frequência que, quando atingidos, disparam um salto de fase adicional para melhorar a detecção de ilhamento, reduzindo o tempo de detecção e mitigando a Zona de Não-Detecção (ZND) sem exigir degradação adicional dos harmônicos de corrente. Além disso, o trabalho realiza uma revisão completa da teoria de ilhamento, abordando o conceito de ZND e suas tecnologias de mapeamento, e conduz uma análise crítica das soluções já existentes, destacando a linha do tempo de evolução de cada algoritmo. Finalmente, para atestar a efetividade da nova solução, será realizado um estudo comparativo com outros métodos de PAI já conhecidos: Deslocamento de Frequência Ativo (AFD), AFD por (CHEN et al., 2013), AFD com Fator de Chopping Pulsante (AFDPCF), Deslocamento de Frequência Sandia (SFS) e o Salto de Fase Ativo com Feedback Positivo (APJPF). A metodologia de teste será baseada nas recomendações dos padrões mais restritivos e os resultados serão categorizados de acordo com três Indicadores de Parâmetros Chave (KPI): tempo de detecção, ZND e THDi. Os resultados obtidos mostram que o esquema proposto atingiu a mitigação da ZND e obteve a detecção de ilhamento mais rápida para todos os casos testados. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.program | Programa de Pós-graduação em Engenharia Elétrica | pt_BR |
dc.sizeorduration | 160 | pt_BR |
dc.subject.cnpq | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::ELETRONICA INDUSTRIAL, SISTEMAS E CONTROLES ELETRONICOS::ELETRONICA INDUSTRIAL | pt_BR |
dc.identifier.doi | http://doi.org/10.14393/ufu.te.2024.712 | pt_BR |
dc.orcid.putcode | 170682733 | - |
dc.crossref.doibatchid | f1950890-3899-4572-88af-b7634ad0b1b2 | - |
dc.subject.autorizado | Engenharia elétrica | pt_BR |
dc.subject.ods | ODS::ODS 7. Energia limpa e acessível - Garantir acesso à energia barata, confiável, sustentável e renovável para todos. | pt_BR |
Appears in Collections: | TESE - Engenharia Elétrica |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
AntiIslandingAlgorithm.pdf | Tese | 6.2 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License