Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/37465
Full metadata record
DC FieldValueLanguage
dc.creatorReis, Karsonn Batista dos-
dc.date.accessioned2023-03-08T14:52:23Z-
dc.date.available2023-03-08T14:52:23Z-
dc.date.issued2022-12-21-
dc.identifier.citationREIS, Karsonn Batista dos. Estudos para determinação de 4-aminofenazona em amostras de cocaína usando eletrodo de carbono vítreo modificado com óxido de grafeno reduzido e azul da Prússia. 2022. 77 f. Dissertação (Mestrado em Química) - Universidade Federal de Uberlândia, Uberlândia, 2018. DOI http://dx.doi.org/10.14393/ufu.di.2023.7016.pt_BR
dc.identifier.urihttps://repositorio.ufu.br/handle/123456789/37465-
dc.description.abstractIn this work we show the electrochemical preparation of a nanocomposite film of reduced graphene oxide and Prussian blue (rGO/FeHCF) and its subsequent application as an electrochemical sensor in the detection of 4-aminophenazone (4AF) in seized cocaine samples. The material was produced on a glassy carbon electrode in a typical three-electrode electrochemical system by cyclic voltammetry (CV) immersed in a GO dispersion with Fe2+ ions. After drying, this precursor was subjected to successive cyclic voltammograms in potassium ferricyanide solution, obtaining the desired rGO/FeHCF nanocomposite. The electrochemical tests after film formation demonstrated a synergistic effect between the materials that could be evidenced by the increase in current intensity and by the good chemical stability during 50 CVs in acid medium (pH = 4). The characterizations carried out by means of Raman spectroscopy and infrared absorption with Fourier transform showed effective reduction of GO as well as the formation of the PB film. The microscopy images showed PB particles well distributed on rGO sheets and their constitution was also confirmed by EDX. In CV studies, investigations were carried out to identify the region where the analyte showed redox activity using the modified and unmodified glassy carbon electrode. Studies carried out by batch injection analysis with amperometric detection demonstrated that the determination of 4AF was possible in cocaine samples (without interference from the common adulterants present in this type of sample). In addition, a comparison was also performed using the unmodified GC electrode for the determination of 4AF. It was noticed that the GC electrode showed better sensitivity for the determination of 4AF, demonstrating that the clean electrode is also a good alternative to the determination of this analyte in forensic samples.pt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal de Uberlândiapt_BR
dc.rightsAcesso Abertopt_BR
dc.subject4 – aminopirinapt_BR
dc.subjecteletrodo modificadopt_BR
dc.subjectvoltametria cíclicapt_BR
dc.subjectamperometriapt_BR
dc.subjecteletroquímicapt_BR
dc.subjectdrogas de abusopt_BR
dc.subject4 – aminopyrinept_BR
dc.subjectmodified electrodept_BR
dc.subjectcyclic voltammetrypt_BR
dc.subjectamperometrypt_BR
dc.subjectelectrochemistrypt_BR
dc.subjectdrugs of abusept_BR
dc.titleEstudos para determinação de 4-aminofenazona em amostras de cocaína usando eletrodo de carbono vítreo modificado com nanocompósito de óxido de grafeno reduzido e azul da Prússiapt_BR
dc.title.alternativeStudies for determination of 4-aminophenazone in cocaine samples using vitreous carbon electrode modified with reduced graphene oxide nanocomposite and Prussian bluept_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Richter, Eduardo Mathias-
dc.contributor.advisor1Latteshttps://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4703638T7&tokenCaptchar=03AFY_a8U-sbaoK_z19fand9xQPSRjgiq8Gepo1Zp3FDUN3-ljtsqAaANfGiMeyk_YJhqudioRtc9omhFM7tX_lON0SLdgDMq75k4uxhpSxHZwnvUtZ4phoOZK-Cbqj5glAaWUkl3_sARX2WQZgFuqN-CMfViRRCFTVqlFHF6WxGhcNIh6zMAbzIRTcloRcj_kKF-FBHaj_FvdZsv_wLTx5HNJXPDIes2LQ35OY16c96KzM1wdH7Ay3mQ4PtG9XYNiRXEjDmUC14iB9B2Ot1k4aYUmr21MRsfwHo1Anxfq6q4-Aaw1gUicrVzUXgGyvzpKVEHlto7wTXlEwlaMq3aoZWZ1jPpN2kikCQqUi5lGKrBAZRu1NKLeaJ7rVrgWfSl-KQIFBiEvvBaU0BgUeLRjg09g_DcdPi2mvVmkrDgbqPzTgl2GC0zBJITp0tqgXFk8-twiakG_YF9cDPCLUd0DBD1Cl7uK9VqkDsLV17EHiiZVyyti3145BXnypTW_KxOkRWYMiBjWTybtbOYLXy-KTDJAbl0Yh1TJqwpt_BR
dc.contributor.referee1Silva, Rodrigo Amorim Bezerra da-
dc.contributor.referee1Latteshttps://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4711461P2&tokenCaptchar=03AFY_a8VleIOmR8VCA7ucmVx5Ou2GRwxV0GltZLySgmeqS8RXTT3S2f7526Xl42DUCEyNkxzhTN7IQFcD2UoFTAMruR4M0XgLw4zRz7bJWoSnSyv28WEsrMboQXzv40u2olV-1geqYn5WEHdbjLRRAOY4qiVbrmE7S4lg6fYOPgip8_emML83wyOhtagMV3ibk7hav_wUQHv-_t2sFcvyzJtkaScxrnKhX8dXTcg5wEPd-YwLT9z7lsegwIaVLPj5SDhkqVJaBy-BAHV6MQwhsicnVmrYmm4EqzYYMjeKtbLzEw6fiF9OQI4cTPDjbaEYarx8nw85Y159zNz6DO87NiM_ookYmYWNxNWs341l6KjmetQdc7yMVEMqjBmaa77LNY3MVJnZI4JX0xbTleKfXXGKU771ZHnssbbHhVczzC18jMvVpBVyyqbuOh-wVmenkRfJ8fxLYZOOW5JoBcNL8X1xXEFd92R5zeYd88z_B2lW9PQdtlZ2LCh1sNhKObtaA9VJjOhEfW1A3w2Ris6M9wrqNH2jVyEgzwpt_BR
dc.contributor.referee2Santos, Wallans Torres Pio dos-
dc.contributor.referee2Latteshttps://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4757933P1&tokenCaptchar=03AFY_a8UR9aa0dHTL6nlOdBwaQUfSOtt535afpZ_9WDKUQtp0biTqgQRfZcq2dL1Ke9Oa-Wr8he_b9FpjS5ZLd4tUwRtuKE_E3oyfkI0_BKBDWWvXu8SAj3Yh84eNef19Nkt8Mj2THtHvRnHfXzYlJ_ltZPi17uxbqLsAsS7aWRoQfxVsIe2r_YsBb6fTfbKQRyUqzdzvS5bJrhdS2iEcBWAmoFPdV6-EosVt4WWkbx6fKPOlXFrQkgcI8IHv1mv1BFz7tYPX4ALRLpwWn186RXnzekMzMQ-hwsCwOimDan01GdYBTyc1-y-y2eOVBgvZaydz8s40GKwio5S2nrUbZmfNiAZFzj7in_3-mbh5Nn_lsOtqRfz2LNly3sNNruXlsHX5SnT2QXPhf12NmMnfaSeptKw9wxjA8m7Rn0kWLr1W14v81sLB4K0rjFhTue1g_2BBY3Ux2c3oqFFs_0Vn9w04zOcGvIIQ2Dk-DsrNMu4ejLDf-7dTtvLHRhaT6WCXS89RUr3nDQ9dqg94LaWkfk7TLLhlzhGXbApt_BR
dc.creator.Latteshttps://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K2620871T4&tokenCaptchar=03AFY_a8WiEjrSzoV0vuqUzt9QUuAYUoKYJG9hwNvEw8p6-9WVMpx7OV2XjttNhJi0K7CdyDcp5A_F-ylb1GG2bWv8wP1ApcW3GDp9LEA861aIUYcObatpSvYRP-UbPjn3sCFdAKWWFmRCElEdb_okfw69hC471GZJcQSDMvB0nyu23QIqgg1k5dpFLwhY_q1wgw_LjJsrPwE0idPm21GS8zPdZeVJ7yDB_2r4BwFrLH1qsoejV0A5unm-X1BDXt1uGBWr_FhyCdm1aEJOjPJlbibK-ef1o51Gr7KiHTd6EjwRkLrnScm0FNIZ1RGv56_aNVDI3loIA9nmM6tg7zNUlreTqhUkOj936wGMI2Si3XEY31gG5GDDfhhlM88DxUgGHnLl_nljRFllFv-ekHkFdoXE-r3ulh0l-XLdKVoxs49HtKt5NBAb-olSe-OrJA7tyUzhteAKOoE4kNcvpD8ydtJtZz5d7IHpS4I6L3NzbUZ3vbTRr3CVBrr8s2CboyPBLSA-xaO1HqS7Fovo0k31q2_FZZil9-Unwwpt_BR
dc.description.degreenameDissertação (Mestrado)pt_BR
dc.description.resumoNeste trabalho mostramos a preparação por via eletroquímica de um filme de nanocompósito de óxido de grafeno reduzido e azul da Prússia (rGO/FeHCF) e sua posterior aplicação como sensor eletroquímico na detecção de 4-aminofenazona (4AF) em amostras de cocaína apreendidas. O material foi produzido sobre um eletrodo de carbono vítreo em um sistema eletroquímico típico de três eletrodos por voltametria cíclica (CV) imerso em uma dispersão de GO com íons Fe2+. Após secagem, este precursor foi submetido a voltamogramas cíclicos sucessivos em solução de ferrocianeto de potássio, obtendo-se o nanocompósito rGO/FeHCF desejado. Os testes eletroquímicos após formação do filme demonstraram um efeito sinérgico entre os materiais que pôde ser evidenciado pelo aumento de intensidade de corrente e pela boa estabilidade química durante 50 CVs em meio ácido (pH = 4). As caracterizações realizadas por meio de espectroscopia Raman e de absorção no infravermelho com transformada de Fourier mostraram efetiva redução do GO bem como a formação do filme de PB. As imagens de microscopia mostraram partículas de PB bem distribuídas sobre folhas de rGO sendo sua constituição também confirmada por EDX. Nos estudos por CV, investigações foram realizadas para identificar a região onde o analito apresentava atividade redox usando o eletrodo de carbono vítreo modificado e não modificado. Estudos realizados por análise por injeção em batelada com detecção amperométrica demonstraram que a determinação de 4AF foi possível em amostras de cocaína (sem interferência dos adulterantes comuns presentes neste tipo de amostra). Além disso, também foi feito uma comparação utilizando o eletrodo de GC para verificar a possibilidade de determinação deste eletrodo de trabalho em relação a 4AF. Além disso, uma comparação também foi realizada usando o eletrodo de GC não modificado para a determinação de 4AF. Percebeu-se que o eletrodo de GC apresentou melhor sensibilidade para a determinação de 4AF, demonstrando que o eletrodo sem modificação também é uma boa alternativa para a determinação deste analito em amostras forenses.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.programPrograma de Pós-graduação em Químicapt_BR
dc.sizeorduration77pt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICApt_BR
dc.identifier.doihttp://doi.org/10.14393/ufu.di.2023.7016pt_BR
dc.crossref.doibatchidbce8a55e-d136-42fe-86b5-e19f1b67d5c6-
dc.subject.autorizadoQuímicapt_BR
dc.subject.autorizadoCocaína - Indústriapt_BR
dc.subject.autorizadoCromatografia a líquido de alta eficiênciapt_BR
dc.subject.autorizadonanocompósito de óxido de grafenopt_BR
Appears in Collections:DISSERTAÇÃO - Química

Files in This Item:
File Description SizeFormat 
EstudosParaDeterminação.pdfDissertação1.78 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.