Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.ufu.br/handle/123456789/35930
ORCID: | http://orcid.org/0000-0001-8655-6808 |
Tipo de documento: | Dissertação |
Tipo de acceso: | Acesso Aberto |
Título: | Desenvolvimento de uma nova ferramenta para análise de estabilidade de tensão no software PSP-UFU: uma plataforma gratuita e de código aberto para estudos de sistemas de potência |
Título (s) alternativo (s): | Development of a new tool for voltage stability analysis in a free and open source software package for power system studies |
Autor: | Oliveira, Samuel Souto |
Primer orientador: | Guimarães, Geraldo Caixeta |
Primer miembro de la banca: | Moura, Fabricio Augusto Matheus |
Segundo miembro de la banca: | Oliveira, Thales Lima |
Tercer miembro de la banca: | Silva, Fernando Bento |
Resumen: | Nos últimos anos vários índices de estabilidade de tensão têm sido desenvolvidos e implementados em programas de simulação de sistemas elétricos de potência com o intuito de auxiliar a análise do problema de instabilidade de tensão, resultando na criação de novas ferramentas computacionais capazes de aprimorar o planejamento e a operação do sistema. Seguindo esta proposta, o presente trabalho tem por objetivo implementar três índices de estabilidade de tensão dentro do programa PSP-UFU (um software livre e de código aberto que realiza estudo de estabilidade dinâmica e transitória, fluxo de potência, curto-circuito e harmônicos) e verificar o desempenho destes quando submetidos a análise dinâmica. O estudo é aplicado a dois casos, sendo o primeiro um sistema radial reduzido de três barras e o segundo o sistema IEEE 14 barras. Os testes são realizados através de incrementos sucessivos de carga em um determinado barramento até que a tensão deste se torne instável. Foram feitos testes considerando diferente tipos de cargas: potência constante, impedância constante e composição mista (40% impedância constante e 60% potência constante). No segundo caso ainda foi estudado o comportamento dos indicadores com e sem a atuação de AVRs. Todos os indicadores mostraram-se promissores, pois seus valores sensitivos diminuíram à medida que o sistema tendia a instabilidade. No segundo caso os indicadores foram capazes de mostrar que o colapso de tensão é postergado quando se utiliza AVRs. Evidencia-se, que o primeiro indicador, 𝑉𝑆𝐼1𝑖=Δ𝑉𝑖/Δ𝑄𝑐𝑖, apresentou a maior sensibilidade, detectando pequenos incrementos de carga, entretanto, o terceiro indicador, 𝑉𝑆𝐼3𝑖=Δ𝑉𝑖/Δ𝑆𝑐𝑖, apresenta a vantagem de contemplar duas situações extremas, incrementos de carga cujas potências sejam puramente ativa ou puramente reativa, contrastando com fato de que os indicadores 1 (𝑉𝑆𝐼1𝑖=Δ𝑉𝑖/Δ𝑄𝑐𝑖) e 2 (𝑉𝑆𝐼2𝑖=Δ𝑉𝑖/ΔP𝑐𝑖) tem sua aplicação limitada a somente uma dessas situações. |
Abstract: | In recent years, several voltage stability indices have been developed and implemented in simulation programs with the aim of helping the analysis of the voltage instability problem of electrical power systems, resulting in the creation of new computational tools capable of improving the system planning and operation. Following this proposal, the present work aims to implement three voltage stability indices within the PSP-UFU software (a free and open-source software that performs studies of transient and dynamic stability, power flow, short-circuit calculation and harmonic) and verify their performance, when submitted to dynamic analysis. The study is applied to two cases, the first is a reduced 3-bus radial system and the second the 14-bus IEEE system. The tests are carried out through successive increments of load on a given bus until its voltage becomes unstable. Tests were performed considering different types of loads: constant power, constant impedance and mixed composition (40% constant impedance and 60% constant power). In the second case, the behavior of the indices with and without the action of AVRs was studied. All indices proved to be promising, because their sensitive values decreased as the system tended to instability. In the second case, the indicators were also able to show that voltage collapse is delayed when using AVRs. It is noteworthy that the first indicator, 𝑉𝑆𝐼1𝑖=Δ𝑉𝑖/Δ𝑄𝑐𝑖, presented greater sensitivity, detecting small increments of load, however, the third indicator, 𝑉𝑆𝐼3𝑖=Δ𝑉𝑖/Δ𝑆𝑐𝑖, has the advantage of contemplating two extreme situations: load increments whose powers are purely active or purely reactive. In contrast, indicators 1 (𝑉𝑆𝐼1𝑖=Δ𝑉𝑖/Δ𝑄𝑐𝑖) and 2 (𝑉𝑆𝐼2𝑖=Δ𝑉𝑖/ΔP𝑐𝑖) can be applied to only one of these two situations. |
Palabras clave: | Índices de estabilidade de tensão Sistemas de potência Simulador dinâmico Análise de sensibilidade PSP-UFU Voltage stability indices Power systems Dynamic simulator Sensitivity analysis |
Área (s) del CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA |
Tema: | Engenharia elétrica Tensão - Concentração Sistemas de energia elétrica Programação de sistemas (Computação) |
Idioma: | por |
País: | Brasil |
Editora: | Universidade Federal de Uberlândia |
Programa: | Programa de Pós-graduação em Engenharia Elétrica |
Cita: | OLIVEIRA, Samuel Souto. Desenvolvimento de uma nova ferramenta para análise de estabilidade de tensão no software PSP-UFU: uma plataforma gratuita e de código aberta para estudos de sistemas de potência. 2022. 112 f. Dissertação (Mestrado em Engenharia Elétrica) - Universidade Federal de Uberlândia, Uberlândia, 2022. DOI http://doi.org/10.14393/ufu.di.2022.388 |
Identificador del documento: | https://doi.org/10.14393/ufu.di.2022.388 |
URI: | https://repositorio.ufu.br/handle/123456789/35930 |
Fecha de defensa: | 18-ago-2022 |
Aparece en las colecciones: | DISSERTAÇÃO - Engenharia Elétrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
DesenvolvimentoNovaFerramenta.pdf | Dissertação | 8.7 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.