Use este identificador para citar ou linkar para este item:
https://repositorio.ufu.br/handle/123456789/35348
ORCID: | http://orcid.org/0000-0001-5573-9142 |
Tipo do documento: | Trabalho de Conclusão de Curso |
Tipo de acesso: | Acesso Aberto |
Título: | Influência do diâmetro da ponta e do espectro de luz de aparelhos fotoativadores nas propriedades de resinas bulk-fill |
Título(s) alternativo(s): | Influence of tip diameter and light spectrum of Curing Units on the properties of Bulk-Fill resin composites |
Autor(es): | Fernandes, Luísa de Oliveira |
Primeiro orientador: | Raposo, Luís Henrique Araújo |
Primeiro coorientador: | Cardoso, Igor Oliveiros |
Primeiro membro da banca: | Prado, Alessandra Maia de Castro |
Segundo membro da banca: | Miranda, Rafael Resende de |
Resumo: | Objective: The aim of this study was to evaluate the influence of different light-curing units (LCUs) with distinct tip diameters and light spectra for activating bulk-fill resins. Materials and methods: The specimens (n=10) were made from a conventional composite (Amaris, VOCO) and bulk-fill resins (Aura Bulk Fill, SDI; Filtek One, 3M ESPE; Tetric Bulk Fill, Ivoclar Vivadent) with two diameters, 7 or 10 mm, x 2 mm thickness. Following 24 h of specimen preparation, the degree of conversion (DC) was evaluated using the FTIR unit. Knoop microhardness (KHN) readings were performed on the center and periphery of the specimens. Data were assessed for homoscedasticity and submitted to 1-way and 3-way analysis of variance followed by the Tukey and Dunnett tests, depending on the analysis performed (α=0.05). Results: LCUs and specimen diameter significantly affected the DC. The Tetric Bulk Fill provided increased DC results when light-cured with Valo (54.8 and 53.5%, for 7 and 10 mm, respectively) compared to Radii Xpert (52.1 and 52.9%, for 7 and 10 mm, respectively). No significant differences in KHN results were noted for the conventional resin composite (Amaris) compared with LCUs (p=0.213) or disc diameters (p=0.587), but the center of the specimen exhibited superior KHN (p≤0.001) than the periphery. Conclusion: The light spectrum of the multipeak LCU (Valo) significantly increased the DC and KHN of the bulk-fill resin composite with additional initiator to CQ (Tetric Bulk Fill) compared to the monowave LCU (Radii Xpert). The tip size of the LCUs influenced the performance of some of the resin composites tested. |
Palavras-chave: | Resinas compostas Composite resins Fotopolimeriação Light curing Polimerização Polymerization |
Área(s) do CNPq: | CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::MATERIAIS ODONTOLOGICOS |
Idioma: | por |
País: | Brasil |
Editora: | Universidade Federal de Uberlândia |
Referência: | FERNANDES, Luísa de Oliveira. Influência do diâmetro da ponta e do espectro de luz de aparelhos fotoativadores nas propriedades de resinas bulk-filll. 2022. 34 f. Trabalho de Conclusão de Curso (Graduação em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2022. |
URI: | https://repositorio.ufu.br/handle/123456789/35348 |
Data de defesa: | 4-Jul-2022 |
Aparece nas coleções: | TCC - Odontologia |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
InfluenciaDiametroPonta.pdf | TCC | 632.48 kB | Adobe PDF | Visualizar/Abrir |
Este item está licenciada sob uma Licença Creative Commons