Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/20800
Tipo de documento: Dissertação
Tipo de acceso: Acesso Aberto
Título: Comportamento mecânico de um modificador de conexão protética (MCP) para implante dental
Título (s) alternativo (s): Mechanical behavior of a prosthetic connection modifier (MCP) for dental implants
Autor: Loureiro, Karine Regina Tolesano
Primer orientador: Magalhães, Denildo de
Primer miembro de la banca: Simamoto Junior, Paulo Cesar
Segundo miembro de la banca: Naves, Marina de Melo
Resumen: Considerando os aspectos positivos da Conexão Morse e para solucionar problemas de posicionamento profundo de implantes Hexágono Externo (HE), esse estudo propõe analisar qualitativamente e quantitativamente por meio de Microscopia Eletrônica de Varredura (MEV), método de Ciclagem Mecânica, aperto e desaperto do parafuso por torquímetro digital, Microscopia Óptica e Radiografias Digitais, o uso de um abutment Modificador de Conexão Protética (MCP) adaptado a implantes Hexágono Externo (HE), transformando sua conexão em tipo Cone Morse (CM). Trinta implantes HE foram incluídos em blocos de resina, sendo divididos em dois grupos: Grupo MCP formado por coroa/abutmentCM/MCP/implante (n=15) e Grupo ABT formado por coroa/abutmentHE/implante (n=15), sendo que 5 amostras de cada grupo formaram o grupo controle que não foi submetido a teste de fadiga. Para a caracterização e análise qualitativa todos os componentes foram submetidos a Microscopia Eletrônica de Varredura e Óptica pré e pós ciclagem mecânica e para o grupo controle pré e pós desaperto do parafuso. Foi avaliado o torque de aperto e desaperto dos parafusos dos 30 conjuntos utilizando um torquímetro Control MK e para o teste de fadiga 10 conjuntos de cada grupo foram submetidos à ciclos mecânicos (1.200.000 ciclos) onde foi aplicada uma força de 50N a uma frequência de 2Hz com inclinação de 30° segundo a norma ISO 14801. Para a análise estatística foi utilizado um nível de significância de α=0,05 e realizado testes paramétricos e testes não paramétricos. As imagens de microscopia eletrônica de varredura foram analisadas qualitativamente e para todos os grupos foram observados antes da ciclagem resíduos de usinagem e após a ciclagem pequenas discrepâncias na morfologia dos hexágonos. Após a ciclagem observou-se a não ocorrência de desaperto do parafuso ou deslocamento axial das próteses avaliadas por radiografias digitais. Após a avaliação estatística intra grupo e entre grupos comparando torque inicial e desaperto, avaliação da média da área interna dos hexágonos e avaliação média do comprimento da circunferência ao redor do hexágono foram observadas diferenças estatisticamente significantes apenas para o grupo ABT. O grupo MCP não apresentou afrouxamento após o ciclismo mecânico apresentando os melhores resultados em relação a adaptação e retenção em comparação com o outro grupo e apresenta características mecânicas adequadas a sua aplicabilidade.
Abstract: Considering the positive aspects of Morse taper (MT) connection and searching for solutions of problems with deep implants of external hexagon implants (EH), the purpose of this study was to analyze qualitatively and quantitatively, through Scanning Electron Microscopy (SEM), Mechanical Cycling, tightening and loosening torque of prosthetic components by a digital torquemeter, Optical Microscopy (OM) and Digital Radiography, the use of an abutment - Prosthetic Connection Modifier (MCP), adapted to EH implants allowing its connection to be converted into a MT type. Thirty EH implants were inserted into polystyrene resin blocks and divided into two groups: MCP group formed by crown/abutmentMT/MCP/implant (n = 15) and Abutment (ABT) Group formed by crown/abutmentEH/implant (n = 15), five specimens from each group composed the control group that was not submitted to fatigue testing. For characterization and qualitative analysis, all components were submitted to Scanning Electronic Microscopy (SEM) and Optical Microscopy (OM) before and after mechanical cycling, and for control group before and after screw loosening. To verify tightening and loosening torque, all thirty specimens were taken to the MK Control torquemeter and for the fatigue test 10 specimens of each group were subjected to mechanical cycling (1,200,000 cycles) subjected to a force of 50 N at a frequency of 2Hz with an inclination of 30 ° according to ISO 14801. For statistics evaluation a significance level of α = 0.05 was used and parametric and non-parametric tests were performed. SEM images were analyzed qualitatively and for all groups before cycling were observed machining residues and after cycling were found slight morphology discrepancies in the hexagons. After cycling, there was no occurrence of loosening or axial displacement of prosthesis evaluated by digital radiographs. After statistical evaluation among groups and intra-group, comparing the initial and loosening torque, evaluation of the mean of internal area of the hexagon and evaluation of the internal length of the circumference, statistically significant differences were observed only for the ABT Group. The MCP group did not present loosening after mechanical cycling, which means that MCP showed better results in adaptation and retention when compared to the other group and MCP presents satisfactory mechanical characteristics to its applicability.
Palabras clave: implantes dentários
dental implants
hexágono externo
external hexagon
cone morse
morse taper
componentes protéticos
prosthetic components.
Área (s) del CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Odontologia
Cita: LOUREIRO, Karine Regina Tolesano. Comportamento mecânico de um modificador de conexão protética (MCP) para implante dental. 2018. 55f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Uberlândia, 2018. Programa de Pós-graduação em Odontologia.
Identificador del documento: http://dx.doi.org/10.14393/ufu.di.2018.127
URI: https://repositorio.ufu.br/handle/123456789/20800
Fecha de defensa: 9-feb-2018
Aparece en las colecciones:DISSERTAÇÃO - Odontologia

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
ComportamentoMecanicoMCP.pdfDissertação2.59 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.