Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufu.br/handle/123456789/19897
ORCID:  http://orcid.org/0000-0002-9823-8855
Tipo de documento: Dissertação
Tipo de acceso: Acesso Aberto
Título: Avaliação do efeito de escala nos valores de carga de colapso de interface entre concreto e polímero reforçado com fibra de carbono
Título (s) alternativo (s): Evaluation of size effect in the interface failure load values between concrete and carbon fiber reinforced polymer
Autor: Borges, Luana Ferreira
Primer orientador: Santos, Antonio Carlos dos
Primer miembro de la banca: Rangel, George Wilton Albuquerque
Segundo miembro de la banca: Peruzzi, Antônio de Paulo
Resumen: Este trabalho apresenta um estudo sobre o fenômeno do deslizamento na interface entre concreto e polímero reforçado com fibra (PRF) de carbono por meio da realização e análise de ensaios experimentais. O objetivo geral é investigar o efeito de escala no descolamento entre concreto e PRF. Buscou-se analisar a influência da variação da dimensão do corpo de prova de concreto no colapso de interface ao manter a mesma geometria de PRF aderida. A metodologia adotada consiste em sobrepor dois corpos de prova cilíndricos sobre o plano de seção transversal e ligados por três tiras de PRF de forma simétrica. A parte inferior do conjunto é fixa e aplica-se uma força de tração na parte superior, induzindo o surgimento de tensões de cisalhamento na interface. Foram utilizados corpos de prova moldados e extraídos de vigas de concreto, com diferentes dimensões: 5cm x 10cm, 10cm x 20cm e 15cm x 30cm. Treze geometrias diferentes do material compósito aderido foram usadas. Em alguns experimentos observou-se a ruptura no concreto, pois alcançou-se a tensão normal limite que o corpo de prova resiste antes de atingir a tensão de cisalhamento necessária para acontecer o descolamento. Isso foi notado principalmente nos corpos de prova menores, que resistem a uma força menor de tração. Não se notou uma influência da dimensão do corpo de prova na força máxima até o descolamento, tensão de cisalhamento e rigidez. Apesar de experimentos com corpos de prova menores levarem a bons resultados na análise do descolamento, verificou-se que o que limita seu uso é que muitas vezes é atingida a tensão normal limite que o concreto resiste, causando sua ruptura. Além disso, nos casos de deslizamento verificados com corpos de prova menores foi necessário utilizar uma geometria de PRF muito pequena, o que conduz a uma elevada tensão de cisalhamento máxima, exigindo o uso de um alto fator de correção. O processo de extração pode causar danos no concreto, como microfissuração, principalmente nos corpos de prova menores. Não foi possível concluir sobre a influência do uso de testemunhos no colapso de interface, mas foi notada uma alteração nas curvas de força versus deslocamento ao se usar corpos de prova extraídos, e em cada ensaio a influência foi de uma forma diferente. Não pareceu adequado analisar o deslizamento em testes com testemunhos.
Abstract: This research is a study about the debonding phenomenon at interface between concrete and carbon fiber reinforced polymer (FRP) by way of performance and analysis of experimental tests. The objective of this study is to investigate the size effect in concrete and FRP debonding. The influence of variation of size concrete specimen on interface failure was analyzed when the same FRP geometry was adhered. Two concrete cylinders specimens are superimposed on plane of cross section, and the specimens are connected by three FRP pieces symmetrically adhered in the longitudinal perimeter. The lower part is fixed and the top is pulled. This induces appearance of shear stresses at interface. Different cylinders specimens made and core samples were used: 5cm x 10cm, 10cm x 20cm and 15cm x 30cm. Different thirteen geometries of the composite material were adhered. The failure happened in concrete in some experiments because concrete reached the normal strength before the shear stress required for the debonding, especially in smaller specimens because the tensile load carrying capacity for these cases is lower. An influence of specimen size was not noticed in the maximum load and shear stresses for debonding, and stiffness. Although experiments with smaller specimens generate good results, the reason that limits their use is the fact that the concrete often reaches the normal stress capacity. In addition, a very small FRP geometry was used in tests of debonding with smaller specimens. The use of a small FRP geometry resulted in a high shear stress, and with this use, it is necessary to use a high correction factor. The extraction process can cause damage to concrete such as micro cracking, especially in smaller specimens. It was not conclude about the influence of use of core samples in interface failures, but a change of the load versus displacement graph was noted. The influence of use of core samples happened differently in each test. An debonding analysis in tests with core samples may not be appropriate.
Palabras clave: Colapso de interface
Interface failure
Descolamento
Debonding
PRF
FRP
Reforço
Strengthening
Efeito de escala
Size effect
Área (s) del CNPq: CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::ESTRUTURAS
Idioma: por
País: Brasil
Editora: Universidade Federal de Uberlândia
Programa: Programa de Pós-graduação em Engenharia Civil
Cita: BORGES, Luana Ferreira. Avaliação do efeito de escala nos valores de carga de colapso de interface entre concreto e polímero reforçado com fibra de carbono. 2017. 157 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Uberlândia, Uberlândia, 2017.
Identificador del documento: http://dx.doi.org/10.14393/ufu.di.2017.22
URI: https://repositorio.ufu.br/handle/123456789/19897
Fecha de defensa: 24-ago-2017
Aparece en las colecciones:DISSERTAÇÃO - Engenharia Civil

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
AvaliacaoEfeitoEscala.pdfDissertação12.36 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.