Please use this identifier to cite or link to this item:
https://repositorio.ufu.br/handle/123456789/17455
Document type: | Dissertação |
Access type: | Acesso Aberto |
Title: | Aplicação de nanotubos de carbono no desenvolvimento de sensores amperométricos para compostos fenólicos |
Author: | Cardoso, Rafael Melo |
First Advisor: | Munoz, Rodrigo Alejandro Abarza |
First coorientator: | Montes, Rodrigo Henrique de Oliveira |
First member of the Committee: | Santos, Wallans Torres Pio dos |
Second member of the Committee: | Silva, Rodrigo Amorim Bezerra da |
Summary: | Este trabalho investiga o desenvolvimento de sensores eletroquímicos empregando eletrodos de carbono vítreo modificados com nanotubos de carbono de paredes múltiplas (MWCNT s) de diferentes diâmetros (110-170 nm x 5-9 μm correspondente ao LD-MWCNT e 6-9 nm x 5 μm correspondente ao SD-MWCNT), tratados quimicamente com ácidos concentrados, em análises voltamétricas e amperométricas na oxidação eletroquímica de hidroquinona (HQ), terc-butil-hidroquinona (TBHQ), catecol (CT) e o pirogalol (PY). A resposta eletroquímica para todos compostos fenólicos em eletrodos de carbono vítreo modificados com materiais nanoestruturados apresentou uma pequena diminuição no sobrepotencial das reações de oxidação. Além disso, as d distância entre potenciais de pico do par redox, o ΔEpico foram consideravelmente reduzidos para LD-MWCNT e ainda mais para SD-MWCNT em comparação com o eletrodo não modificado. Testes voltamétricos evidenciaram um aumento substancial de corrente resposta de até três vezes para a oxidação de HQ, TBHQ e PY em GCE modificado com SD-MWCNT. Medições amperométricas acopladas a sistema BIA realizadas em dois potenciais de trabalho diferentes para cada analito também revelaram o melhor desempenho de SD-MWCNT na detecção dos antioxidantes estudados, com aumento de até quatro vezes na sensibilidade, com destaque para a detecção em menores potenciais E=0,5V para HQ, TBHQ e PY e E=0,6V para CT. Os resultados analíticos obtidos em menor potencial foram, respectivamente para HQ, TBHQ, CT e PY: amplas faixas lineares de trabalho de 1 a 1000 μmol L-1, baixos limites de detecção de 0,014 μmol L-1 / 0,011 μmol L-1 / 0,034 μmol L-1 / 0,013 μmol L-1, baixos desvios padrão relativos de 0,9 % / 3,5 % / 1,3 % / 2,8 %, elevada frequência analítica teórica de 1368,9 injeções h-1 / 820,7 injeções h-1 / 1018,7 injeções h-1 / 987,8 injeções h-1, empregando sistema de análise por injeção em batelada (BIA). Além disso, um método amperométrico para a determinação de PY em biodiesel usando eletrodo modificado com SD-MWCNT foi desenvolvido e aplicado a amostras de biodiesel de soja, canola e algodão fortificadas com o antioxidante, obtendo-se valores de recuperação de 95%. |
Abstract: | This work investigates the development of electrochemical sensors employing glassy-carbon electrodes modified with multi-walled carbon nanotubes (MWCNT). Two different diameters (110-170 nm x 5-9, μm corresponding to LD-MWCNT, and 6-9 nm x 5 μm, corresponding to SD-MWCNT), chemically treated with concentrated acids, subjected to amperometric and voltammetric analyses for the electrochemical oxidation of hydroquinone (HQ), tert-butylhydroquinone (TBHQ), catechol (CT), and pyrogallol (PY). The electrochemical response for all phenolic compounds in glassy-carbon electrode modified with nanostructured materials showed a small decrease in the overpotential of oxidation reactions (<80 mV). Furthermore, the values of ΔEpeak (distance between peak potential of the redox pair) were substantially reduced at LD-MWCNT and even more at SD-MWCNT compared to the unmodified electrode. Voltammetric tests showed a substantial increase (three fold) in oxidation current for the HQ, TBHQ, and PY on the modified electrode with SD-MWCNT. Amperometric measurements coupled to BIA system conducted in two different working potentials for each analyte also revealed the best performance of SD-MWCNT (increase up to four fold in sensitivity) for the detection of studied antioxidants, especially for the detection at lower potentials (0.5 V to HQ, TBHQ and PY and 0.6 V to CT). The analytical results obtained at lower potentials were respectively for HQ, TBHQ, CT and PY: large linear concentration ranges from 1 to 1000 μmol L-1; low limits of detection, 0.014 μmol L-1 / 0.011 μmol L-1/ 0.034 μmol L-1/ 0.013 μmol L-1; low relative standard deviation values, 0.9% / 3.5% / 1.3% / 2.8% , high theoretical analytical frequency, 1368,9 injections h-1 / 820,7 injections h-1 / 1018,7 injections h-1 / 987,9 injections h-1, employing the batch-injection analysis system. Moreover, an amperometric method for the determination of PY was developed and applied for biodiesel samples (produced from soybean, canola and cottonseed oils) spiked with the antioxidant, and recovery values of 95% were obtained. |
Keywords: | Biodiesel Antioxidantes Nanotubos de carbono Sensores Eletroanálise Antioxidants Carbon nanotubes Sensors Eletroanalysis Química analítica |
Area (s) of CNPq: | CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA |
Language: | por |
Country: | BR |
Publisher: | Universidade Federal de Uberlândia |
Institution Acronym: | UFU |
Department: | Ciências Exatas e da Terra |
Program: | Programa de Pós-graduação em Química |
Quote: | CARDOSO, Rafael Melo. Aplicação de nanotubos de carbono no desenvolvimento de sensores amperométricos para compostos fenólicos. 2016. 101 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2016. DOI http://doi.org/10.14393/ufu.di.2016.210 |
Document identifier: | http://doi.org/10.14393/ufu.di.2016.210 |
URI: | https://repositorio.ufu.br/handle/123456789/17455 |
Date of defense: | 3-Mar-2016 |
Appears in Collections: | DISSERTAÇÃO - Química |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
AplicacaoNanotubosCarbono.pdf | 3.88 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.