Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/17046
Document type: Dissertação
Access type: Acesso Aberto
Title: Distribuição das tensões geradas em implantes interconectados com barra dolder, após solda a laser
Author: Araújo Filho, Glécio Clemente de
First Advisor: Gomes, Vanderlei Luiz
First coorientator: Araújo, Cleudmar Amaral de
First member of the Committee: Fernandes Neto, Alfredo Júlio
Second member of the Committee: Barbosa, Gustavo Augusto Seabra
Summary: Próteses implanto-retidas, necessitam de passividade e justeza no seu assentamento sendo considerados pré-requisitos para o sucesso da osseointegração. Para minimizar distorções e promover assentamento passivo utiliza-se o corte e solda das infra-estruturas metálicas. Este estudo investigou, por meio da fotoelasticidade, a distribuição de tensões geradas quando implantes são interconectados por barra metálica fundida, seccionada e soldada a laser. Foram obtidos, a partir de moldes de silicone, seis modelos fotoelásticos contendo os conjuntos implantes/pilares/barras metálicas indexadas, correspondendo à fase clínica de remoção para soldagem, com o objetivo de zerar as interferências anteriores ao processo de soldagem. Levando o conjunto ao polariscópio, observouse ausência de tensões nos modelos. Posteriormente, as barras foram soldadas a laser em laboratório comercial e reposicionadas nos modelos fotoelásticos, avaliando-se vinte e cinco pontos ao longo dos corpos dos implantes e região interimplantar, sob duas condições: após torque de 20 Ncm e sob carregamento de 2 KgF. Na primeira condição, os gradientes de tensão cisalhante máxima foram praticamente nulos em todos os pontos avaliados, havendo uniformidade nos padrões de franjas desenvolvidos nos seis modelos, sugerindo simetria na adaptação entre os componentes do sistema e que o processo de soldagem a laser pode influenciar positivamente no nível de tensões gerados, constituindo-se em procedimento técnico-sensitivo. Com aplicação de carga externa, observou-se que os padrões de tensão se distribuíram uniformemente, por não ter ocorrido tensão após o processo de soldagem a laser.
Abstract: The Implant-retained prostheses need passivity and justness in their settlement, which are considered prerequisites for the osseointegration success. To minimize distortions and to promote passive settlement it is used the cut and solder of the piece. This work investigated, through photoelasticity, the distribution of stress generated by implants interconnected with a laser welded, sectioned, molten and metallic bar. Six photoelastics models, which contain the implant groups/pillars/indexed and cut bars, were obtained from silicone molds avoiding supposed stress proceeded from dimensional alterations caused by the acrylic resin polymerization process, which is utilized bars indexation. Stress absence was observed In the models, on a polariscopic. Afterwarsds, the bars were soldered by laser in the laboratory and repositioned into the photoelastics models; twenty-five points, in the body of implants and inter-implant region, were evaluated under two conditions: after torque of 20 Ncm and under loading of 2 KgF. In the first condition, the maximum shear tension gradients were practically null in all evaluated points, the developed patterns of fringes- in all the models (1 to 6) - were uniform, suggesting symmetry among the system components during the adaptation process and some possible positive influence caused by the laser soldering process on the level of generated stress; it - the process has been characterized as a technical-sensitive procedure. The uniform distribution of stress patterns was observed with the application of external loading because of stress absence after the laser soldering process.
Keywords: Soldagem
Adaptação
Tensão
Fotoelasticidade
Implants
Soldering
Adaptation
Stress
Photoelasticity
Implantes dentários
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
Language: por
Country: BR
Publisher: Universidade Federal de Uberlândia
Institution Acronym: UFU
Department: Ciências da Saúde
Program: Programa de Pós-graduação em Odontologia
Quote: ARAÚJO FILHO, Glécio Clemente de. Distribuição das tensões geradas em implantes interconectados com barra dolder, após solda a laser. 2007. 116 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de Uberlândia, Uberlândia, 2007.
URI: https://repositorio.ufu.br/handle/123456789/17046
Date of defense: 26-Jun-2007
Appears in Collections:DISSERTAÇÃO - Odontologia

Files in This Item:
File Description SizeFormat 
GCAFilhoDISPRT.pdf1.59 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.