Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/17033
Document type: Dissertação
Access type: Acesso Aberto
Title: Influência de diferentes retentores intra- radiculares na deformação de dentes tratados endodonticamente frente ao teste de impacto
Author: Martins, Victor da Mota
First Advisor: Santos Filho, Paulo César de Freitas
First member of the Committee: Menezes, Murilo de Sousa
Second member of the Committee: Fonseca, Rodrigo Borges
Summary: O objetivo deste estudo foi avaliar a influência de diferentes retentores intra-radiculares na deformação de dentes tratados endodonticamente frente ao ensaio mecânico de impacto. Quarenta raízes de incisivos bovinos com 15 mm de comprimento foram selecionados, tratados endodonticamente e incluídos em cilindros de resina com simulação do ligamento periodontal. As raízes foram divididas aleatoriamente em dois grupos (n=20) de acordo com o tipo de retentor intra-radicular a ser restaurado: Núcleo Metálico Fundido (NMF) e Pino de fibra de vidro (PFV). Após restaurados, as raízes foram armazenadas sob refrigeração constante e em seguida, a porção coronal dos retentores foram moldadas para confecção de coroas fabricadas em liga de Ni-Cr. Medidores de deformação foram fixados na face vestibular da porção radicular e submetido ao teste de impacto. Um dispositivo pendular semelhante ao teste de impacto convencional de Charpy foi usado, onde foram realizados testes utilizando 2 diferentes ângulos: 90 ° e 45 ° (n = 10) direcionados no centro vestibular da coroa. A deformação foi calculada e os dados foram analisados com a two-way ANOVA (α = 0,05). O resultado mostrou não haver uma diferença estatisticamente significativa (P = 0,151) para tipos de pino utilizados (NMF e PFV). Da mesma forma, que não há uma diferença estatisticamente significativa (P = 0,268) para os tipos de ângulos utilizados no estudo (90º e 45º). Não houve uma interação estatisticamente significativa entre o uso dos pinos e o ângulo do teste de impacto (P = 0,478). Em conclusão, não houve diferença significativa no padrão de deformação entre os diferentes retentores e os ângulos do teste.
Abstract: The aim of this study was to evaluate the influence of different post in a strain behavior of endodontically treated teeth on impact test. Forty bovine incisor roots with 15 mm in length were selected, treated endodontically and included in resin cylinders with simulated periodontal ligaments. The roots were randomly divided into two groups (n = 20) according to the type of post to be restored: Cast post and core (Cpc) and Glass fiber post (Gfp). Once restored, the roots were stored under constant refrigeration and then the coronal portion of post were molded for making crowns made of Ni-Cr alloy. Strain gauges were attached at the bucal surface of the root portion and subjected to the impact test. A pendulum device similar to the conventional Charpy impact test was used, it were performed using two different angles: 90 º and 45º (n = 10) at the center of the buccal crown. The strain was calculated and data were analyzed with 2-way ANOVA (α = 0.05). The results showed no statistically significant difference (P = 0.151) used to post (Cpc and Gfp). There was not a statistically significant difference (P = 0.268) for the types of angles used in the study (90º and 45º). There was not a statistically significant interaction between post and use the angle of the impact test (P = 0.478). In conclusion, there was no substantial difference in peak strains among the different post and impact angles.
Keywords: Núcleo metálico fundido
Pinos de fibra de vidro
Teste de impacto
Dentina radicular
Deformação
Cast post and core
Glass fiber post
Impact test
Root dentin
Strain
Pinos dentários
Dentina
Endodontia - tratamento
Area (s) of CNPq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
Language: por
Country: BR
Publisher: Universidade Federal de Uberlândia
Institution Acronym: UFU
Department: Ciências da Saúde
Program: Programa de Pós-graduação em Odontologia
Quote: MARTINS, Victor da Mota. Influência de diferentes retentores intra- radiculares na deformação de dentes tratados endodonticamente frente ao teste de impacto. 2016. 62 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de Uberlândia, Uberlândia, 2016. DOI http://doi.org/10.14393/ufu.di.2016.20
Document identifier: http://doi.org/10.14393/ufu.di.2016.20
URI: https://repositorio.ufu.br/handle/123456789/17033
Date of defense: 1-Feb-2016
Appears in Collections:DISSERTAÇÃO - Odontologia

Files in This Item:
File Description SizeFormat 
InfluenciaDiferentesRetentoresIntra.pdf1.33 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.