Use este identificador para citar ou linkar para este item:
https://repositorio.ufu.br/handle/123456789/16676
Tipo do documento: | Dissertação |
Tipo de acesso: | Acesso Aberto |
Título: | Análise cinética da resposta imune humoral contra a proteína recombinante SAG2A em pacientes com Toxoplasmose aguda |
Autor(es): | Santana, Silas Silva |
Primeiro orientador: | Cunha Junior, Jair Pereira da |
Primeiro coorientador: | Mineo, Jose Roberto |
Primeiro membro da banca: | Abdallah, Vânia Olivetti Steffen |
Segundo membro da banca: | Pirovani, Carlos Priminho |
Resumo: | Proteínas recombinantes de Toxoplasma gondii têm sido utilizadas em diversos modelos experimentais, assim como para o diagnóstico sorológico da infecção humana por este parasito, principalmente com o intuito de diferenciar as fases aguda e crônica da toxoplasmose. Neste estudo, foi avaliada a cinética dos anticorpos IgM, IgA ,IgG e subclasses (IgG1 e IgG3) através de imunoensaios realizados em amostras seqüenciais de soros humanos, provenientes de pacientes com toxoplasmose aguda. Estas amostras foram testadas frennte ao antígeno recombinante SAG2A, utilizando-se como paradigma de comparação o antígeno solúvel total de Toxoplasma (STAg). A avidez do anticorpo IgG1 foi avaliada utilizando a metodologia slot-blot. Adicionalmente, a razão entre as subclasses IgG3 e IgG1 (IgG3:IgG1) foi determinada e avaliada quanto ao grau de associação com os níveis de IgM e IgA específicos para STAg e aos índices avidez de IgG1 específicos para SAG2A. Os resultados demonstraram a presença de níveis decrescentes de IgM e IgA para ambos os antígenos utilizados, enquanto que para o isotipo IgG o perfil cinético demonstrou níveis crescentes para ambas preparações antígênicas. Em relação aos índices de avidez para IgG1, foi observado que amostras de soros de uma fase inicial apresentaram baixa avidez média de anticorpos IgG1 dirigidos para SAG2A, enquanto que as mesmas amostras demonstraram avidez média intermediária de IgG1 quando STAg foi utilizado como antígeno. Já em uma fase mais tardia, a avidez média observada foi alta para STAg e intermediária com SAG2A. A razão entre IgG3:IgG1 obtida no primeiro bimestre foi significantemente maior para SAG2A em comparação com STAg. Tomados em conjunto, os resultados obtidos no presente estudo indicam que a proteína recombinantes SAG2A pode se constituir em uma ferramenta efetiva na diferenciação das fases da infecção humana por T. gondii. |
Abstract: | Recombinant proteins from Toxoplasma gondii have been used in several experimental models, as well as for serodiagnosis of human toxoplasmosis, particularly to differentiate acute from chronic phases of the infection. In the present study, we evaluated the kinetics of IgM, IgA, and IgG isotypes, in addition to IgG1 and IgG3 subclasses, by testing sequential serum samples from patients with acute toxoplasmosis. It was carried out immunoassays by using SAG2A recombinant antigen and soluble antigen of Toxoplasma (STAg). The avidity of IgG1 antibody was assessed using slot blot assay. Additionally, a ratio between IgG1 and IgG3 subclasses (IgG3:IgG1) was determined and evaluated its degree of association with levels of IgM and IgA specific for STAg and the avidity index of IgG1 specific for SAG2A. The results showed a decreasing kinetic profile for SAG2A and STAg for IgM and IgA. The kinetic profile for the IgG antibody was increasing for both antigens. Compared to the avidity for IgG1, it was observed that sera from an early stage showed a low average avidity of IgG1 for SAG2A while the same samples showed intermediate mean avidity of IgG1 when STAg was used as antigen. In a later phase, the average avidity observed was high for STAg and intermediate for SAG2A in the same tested sera suggesting that SAG2A may be a promising tool for the detection of avidity. Associations between IgG3/IgG1 and specific IgM and IgA levels for STAg and the avidity index of specific IgG1 for SAG2A were found, and together these parameters could be used as valuable tools in the diagnosis of human toxoplasmosis, especially in situations when the determination of different phases is critical. |
Palavras-chave: | Toxoplasma gondii Toxoplasmose Diagnóstico sorológico Antígeno SAG2A Antígeno recombinante Anticorpos IgM e IgG Subclasses de IgG Avidez de anticorpo Serological diagnosis SAG2A molecule Recombinant antigen IgM and IgG isotypes IgG subclasses Antibody avidity Toxoplasmose - Diagnóstico Imunologia |
Área(s) do CNPq: | CNPQ::CIENCIAS BIOLOGICAS::IMUNOLOGIA::IMUNOLOGIA APLICADA |
Idioma: | por |
País: | BR |
Editora: | Universidade Federal de Uberlândia |
Sigla da instituição: | UFU |
Departamento: | Ciências Biológicas |
Programa: | Programa de Pós-graduação em Imunologia e Parasitologia Aplicadas |
Referência: | SANTANA, Silas Silva. Análise cinética da resposta imune humoral contra a proteína recombinante SAG2A em pacientes com Toxoplasmose aguda. 2011. 82 f. Dissertação (Mestrado em Ciências Biológicas) - Universidade Federal de Uberlândia, Uberlândia, 2011. |
URI: | https://repositorio.ufu.br/handle/123456789/16676 |
Data de defesa: | 28-Mar-2011 |
Aparece nas coleções: | DISSERTAÇÃO - Imunologia e Parasitologia Aplicadas |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
d.pdf | 1.18 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.