Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/14635
Document type: Dissertação
Access type: Acesso Aberto
Title: Avaliação de desempenho do gerador de indução trifásico assimétrico conectado a uma rede monofásica: aplicações rurais
Alternate title (s): Evaluation of performance of the assymmetrical three - phase induction generator connected to single-phase supply system rural applications
Author: Carvalho, Hamilton Dias de
First Advisor: Martins Neto, Luciano
First member of the Committee: Souza, Cláudio Lemos de
Second member of the Committee: Andrade, Darizon Alves de
Summary: O objetivo deste trabalho é obter o projeto e a construção de um gerador de indução trifásico assimétrico conectado a um sistema de distribuição de energia elétrica monofásica; visando aplicá-lo em áreas rurais. Este dispositivo, em face de sua robustez, baixo custo, menores requisitos de manutenção e bom desempenho, consiste numa alternativa bastante atrativa em relação às outras propostas existentes atualmente. O estudo teórico inicia-se através da elaboração de uma modelagem matemática para o sistema, no domínio da freqüência, cujas equações são colocadas em função de um fator indicativo do nível de desbalanceamento, visando à obtenção de tensões balanceadas na carga. Para tanto, a modelagem matemática elaborada é implementada num simulador desenvolvido no programa Microsoft Excel. A partir desta implementação, são efetuados estudos de casos no sentido de evidenciar as potencialidades do gerador assimétrico conectado a cargas rurais. Os trabalhos computacionais são devidamente validados à luz de resultados experimentais extraídos de um protótipo de equipamento concebido, projetado e construído para fins deste trabalho.
Abstract: This work has for motive to obtain the project and build of an assymmetrical three-phase induction generator connected to single-phase supply system, in order to be used in rural areas. This equipment has been presented as a better alternative in relation the others proposed more commercialized at the moment, due to its robustness, low cost, less maintenance requirements and excellent performance. Firstly, in the theoric part concerned to the system it is presented a mathematical representation, frequency domain mathematical model, whose equations are performed in function of an unbalance factor in order to obtain balance three-phase voltages in the system. Then, some simulations are performed in the simulator that was developed in the Microsoft Excel program. From these implements, it is carried out study cases to prove the assymmetrical three-phase induction generator use potentialities. A prototype is projected and built, which experimental results are compared to the computer result.
Keywords: Gerador de indução trifásico assimétrico
Rede monofásica
Fator de desbalanceamento
Propriedades rurais
Freqüência constante
Tensões balanceadas
Assymmetrical three-phase induction Generator
Single-phase supply system
Unbalance factor
Country properties
Constant frequency
Balanced voltages
Area (s) of CNPq: CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Language: por
Country: BR
Publisher: Universidade Federal de Uberlândia
Institution Acronym: UFU
Department: Engenharias
Program: Programa de Pós-graduação em Engenharia Elétrica
Quote: CARVALHO, Hamilton Dias de. Avaliação de desempenho do gerador de indução trifásico assimétrico conectado a uma rede monofásica: aplicações rurais. 2006. 111 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2006.
URI: https://repositorio.ufu.br/handle/123456789/14635
Date of defense: 30-Jun-2006
Appears in Collections:DISSERTAÇÃO - Engenharia Elétrica

Files in This Item:
File Description SizeFormat 
AvaliacaoDesempenhoGerador.pdf1.31 MBAdobe PDFThumbnail
View/Open
HDCarvalhoDIS02PRT.zip1.43 MBUnknownView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.