Publicação: Comparação entre dados experimentais e teóricos de lajes maciças armadas em uma direção
Carregando...
Arquivos
Tipo do documento
Data
Direito de acesso
Coleções
Programa
Área do conhecimento
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::ESTRUTURAS::ESTRUTURAS DE CONCRETO
Título da Revista
ISSN da Revista
Título de Volume
Orientador
Coorientador
Resumo
Neste trabalho, estudou-se o comportamento de lajes maciças submetidas à flexão simples com
foco na comparação entre os valores experimentais e normativos. Nesse sentido, nove lajes, com
espessuras variando entre 8, 11 e 14 cm e com armaduras variando entre somente inferior, somente
superior e conjuntamente superior e inferior, foram submetidas à uma carga distribuída em uma
faixa que distava 45° dos centros dos apoios, induzindo assim o rompimento das mesmas por força
cortante. Foram obtidos dados de força e deslocamento dos ensaios afim de confrontar com os
resultados normativos. As normas utilizadas foram a ABNT NBR6118:2014 e ACI318-19, ambas
voltadas á estruturas de concreto. Realizou-se a verificação da força cortante, da punção e flexão
das lajes. Ao final, quando se comparou os resultados experimentais e téoricos, observou-se que,
mesmo não considerando os coeficientes de segurança nas equações, a força de ruptura foi superior
ao valores normativos, verificando assim todo o amparo e segurança que as normas trazem.
Conclui-se que a espessura da laje aumenta a sua resistência como um todo e o uso de armaduras
inferiores é crucial nos elementos.
Abstract
In this work, the behavior of solid slabs subjected to simple bending was studied,
focusing on the comparison between experimental and normative values. In this sense, nine
slabs, with thicknesses varying between 8, 11 and 14 cm and with reinforcement varying
between only the bottom, only the top and both top and bottom, were subjected to a load
distributed in a range that was 45° away from the centers of the supports, thus inducing their
rupture by cutting force. Force and displacement data from the tests were obtained in order
to compare with the normative results. The standards used were ABNT NBR6118:2014 and
ACI318-19, both focused on concrete structures. The verification of shear force, punching
and bending of the slabs was carried out. In the end, when the experimental and theoretical
results were compared, it was observed that, even not considering the safety coefficients in
the equations, the rupture force was higher than the normative values, thus verifying all the
support and safety that the standards bring. It is concluded that the thickness of the slab
increases its resistance as a whole and the use of inferior reinforcement is crucial in the
elements.
Palavras-chave
Lajes maciças, Concreto armado, Força cortante, Valores normativos, Solid slabs, Reinforced concrete, Shear force, Normative values
Citação
FERREIRA, Adriano Borges Pereira. Comparação entre dados experimentais e teóricos de lajes maciças armadas em uma direção. 2023. 30 f. Trabalho de Conclusão de Curso (Graduação em Engenharia Civil) – Universidade Federal de Uberlândia, Uberlândia, 2023.