dc.identifier.citationBENONI,Guilherme Mendonça. Ability of low-cost generic and reference light-cure a bulk-fill resin-based composite. 2024.27 f. Trabalho de Conclusão de Curso (Graduação em Odontologia) - Universidade Federal de Uberlândia, Uberlândia, 2024.pt_BR
dc.identifier.urihttps://repositorio.ufu.br/handle/123456789/41668-
dc.description.abstractThe Knoop hardness (KH) of OPUS Bulk Fill APS (FGM) resin-based composite (RBC) was compared after it had been light-cured using four different light-curing units (LCUs). The VRNVAFU Black and VRN-VAFU Purple (Guilin Veirun Medical Technology Co., Ltd.) were classified as generic low-cost LCUs and were compared to the VALO Grand and VALO Cordless, (Ultradent). The RBC specimens (n = 10) were light-cured for 20 s in standard mode or 3 s in the high-power mode. Power, energy, and emission spectra were measured using an integrating sphere attached to a fiber optic spectrometer. Irradiance was calculated, and beam profiles were obtained. The KH was measured at the top and bottom surfaces. Data were analyzed using two-way ANOVA and the Tukey test (α = 0.05). The irradiance and power were higher in the high-power 3 s mode, but the radiant exposures delivered to the RBCs were significantly higher in the standard mode, irrespective of LCU. The generic LCU's beam profile was heterogeneous and lacked violet light (400 nm). Both curing modes and LCUs produced similar top KH values, >52 in Opus Bulk fill (FGM), but there was a significant reduction in the KH at the bottom in the high-power 3 s mode for all four LCUs. The high-power 3 s mode delivered less energy and produced lower KH values at the bottom surfaces. Thus, short exposure times with high irradiance should not be used with this brand of RBC.pt_BR
dc.description.sponsorshipCNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológicopt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Uberlândiapt_BR
dc.rightsAcesso Embargadopt_BR
dc.subjectLight-curing unitspt_BR
dc.subjectEnergypt_BR
dc.subjectMultiwavept_BR
dc.subjectKnoop hardnesspt_BR
dc.subjectResin-based compositespt_BR
dc.titleAbility of low-cost generic and reference light-cure a bulk-fill resin-based compositept_BR
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.contributor.advisor-co1Ribeiro, Maria Tereza Hordones-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/422301269349295pt_BR
dc.contributor.advisor1Soares, Carlos José-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3485765805045929pt_BR
dc.contributor.referee2Soares, Priscilla Barbosa Ferreira-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/5032809676969673pt_BR
dc.contributor.referee3Zancopé, Karla-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/3332030650229619pt_BR
dc.contributor.referee4Latteshttp://lattes.cnpq.br/3500924957597009pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4058887093467577pt_BR
dc.description.degreenameTrabalho de Conclusão de Curso (Graduação)pt_BR
dc.description.resumoThe Knoop hardness (KH) of OPUS Bulk Fill APS (FGM) resin-based composite (RBC) was compared after it had been light-cured using four different light-curing units (LCUs). The VRNVAFU Black and VRN-VAFU Purple (Guilin Veirun Medical Technology Co., Ltd.) were classified as generic low-cost LCUs and were compared to the VALO Grand and VALO Cordless, (Ultradent). The RBC specimens (n = 10) were light-cured for 20 s in standard mode or 3 s in the high-power mode. Power, energy, and emission spectra were measured using an integrating sphere attached to a fiber optic spectrometer. Irradiance was calculated, and beam profiles were obtained. The KH was measured at the top and bottom surfaces. Data were analyzed using two-way ANOVA and the Tukey test (α = 0.05). The irradiance and power were higher in the high-power 3 s mode, but the radiant exposures delivered to the RBCs were significantly higher in the standard mode, irrespective of LCU. The generic LCU's beam profile was heterogeneous and lacked violet light (400 nm). Both curing modes and LCUs produced similar top KH values, >52 in Opus Bulk fill (FGM), but there was a significant reduction in the KH at the bottom in the high-power 3 s mode for all four LCUs. The high-power 3 s mode delivered less energy and produced lower KH values at the bottom surfaces. Thus, short exposure times with high irradiance should not be used with this brand of RBC.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.courseOdontologiapt_BR
dc.sizeorduration27pt_BR
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDEpt_BR
dc.description.embargo2026-04-08-
Appears in Collections:TCC - Odontologia

Files in This Item:
File Description SizeFormat 
AbilityLowCost.pdf
  Until 2026-04-08
Arquivo de TCC Guilherme Mendonça Benoni1.97 MBAdobe PDFView/Open    Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.