Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/32696
Full metadata record
DC FieldValueLanguage
dc.creatorGomes Júnior, Oswaldo-
dc.date.accessioned2021-09-03T19:27:17Z-
dc.date.available2021-09-03T19:27:17Z-
dc.date.issued2021-07-30-
dc.identifier.citationGOMES JÚNIOR, Oswaldo. Potencial do processo foto-Fenton como etapa complementar ao tratamento de esgoto urbano e efluentes de indústria agroquímica. 2021. 167 f. Tese (Doutorado em Química) - Universidade Federal de Uberlândia, Uberlândia, 2021. http://doi.org/10.14393/ufu.te.2021.5533.pt_BR
dc.identifier.urihttps://repositorio.ufu.br/handle/123456789/32696-
dc.description.abstractThis work evaluated the potential of photo-Fenton process as a complementary step to the treatment of urban sewage aiming at the degradation of ciprofloxacin (CIP) (3.3 mg L–1) and fipronil (FIP) (1.0 mg L–1). In addition, this process was evaluated as an alternative treatment for decontamination and toxicity reduction of an agrochemical effluent containing 403 mg L–1 of ametrine (AMT), 2153 mg L–1 of atrazine (ATZ), 2936 mg L–1 of imidacloprid (IMD) and 3354 mg L–1 of tebuthiuron (TBT). Initially, a preliminary study was carried out to evaluate the influence of operational parameters (pH, source and iron concentration and, molar Fe3+/ligand ratio) on the performance of the modified photo-Fenton process for the degradation of CIP and FIP at near to environmental conditions. 90% of CIP degradation were obtained in distilled water at pH 6.0–6.5 using 10 μmol L–1 of FeCit while 98% of FIP degradation (using 32 μmol L–1 of FeCit) were obtained using the molar Fe3+/citrate ratio equivalent to 1:3. 83% of FIP degradation was obtained in sewage treatment plant effluent (STP) at pH 6.0. However, FeCit concentration had to increase 6 times (192 μmol L–1) to reach this efficiency due to the influence of organic matter and inorganic ions present in the STP effluent. Three and eight transformation products (TP) were detected for CIP and FIP, respectively. Results revealed that the degradation of CIP and FIP through the photo-Fenton process occurred preferentially via HO• attack on the piperazine ring of CIP and the pyrazole ring of FIP. The treatment of the agrochemical effluent initially occurred via coagulation-flocculation-settling (using 8 mmol L–1 of Fe(NO3)3) and reached 99% removal of both color and turbidity. Then, the photo-Fenton process was applied resulting in effective degradation of pesticides ([AMT, ATZ, IMD and TBT] ≤ 10 μg L–1 (using 2 mmol L–1 of FeOx and sunlight)). In addition, 79% and 71% reduction of chemical oxygen demand (COD) and biological oxygen demand (BOD5), respectively, were obtained. The use of solar radiation in the photo-Fenton process enhanced degradation kinetics of target compounds when compared to experiments performed under black light lamps. Acute toxicity monitoring (mortality of the D. melanogaster flies (for FIP) and the inhibition of luminescence emitted by V. fischeri (for the agrochemical effluent)) indicated that the photo-Fenton process was effective in the degradation of CIP and FIP as well as for toxicity reduction. In general, these results show that the photo-Fenton process is a viable alternative for the degradation of emerging contaminants in distilled water and STP effluent and, also for the treatment of agrochemical effluent.pt_BR
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.description.sponsorshipCNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológicopt_BR
dc.description.sponsorshipFAPEMIG - Fundação de Amparo a Pesquisa do Estado de Minas Geraispt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal de Uberlândiapt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectContaminantes de preocupação emergentept_BR
dc.subjectContaminants of emerging concernpt_BR
dc.subjectFármacospt_BR
dc.subjectPharmaceuticalspt_BR
dc.subjectPesticidaspt_BR
dc.subjectPesticidespt_BR
dc.subjectProcessos Oxidativos Avançadospt_BR
dc.subjectAdvanced oxidation processpt_BR
dc.subjectLuz solarpt_BR
dc.subjectSunlightpt_BR
dc.subjectToxicidadept_BR
dc.subjectToxicitypt_BR
dc.subjectProdutos de transformaçãopt_BR
dc.subjectTransformation productspt_BR
dc.titlePotencial do processo foto-Fenton como etapa complementar ao tratamento de esgoto urbano e efluentes de indústria agroquímicapt_BR
dc.title.alternativePotential of photo-Fenton process as a complementary step to the treatment of urban sewage and agrochemical industry effluentpt_BR
dc.typeTesept_BR
dc.contributor.advisor1Trovó, Alam Gustavo-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7274761440886112pt_BR
dc.contributor.referee1Lopes, Osmando Ferreira-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/9493281509128559pt_BR
dc.contributor.referee2Vieira, Patrícia Angélica-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2299169749872951pt_BR
dc.contributor.referee3Dantas, Renato Falcão-
dc.contributor.referee3Latteslattes.cnpq.br/8810347636088336pt_BR
dc.contributor.referee4Guimarães, José Roberto-
dc.contributor.referee4Latteslattes.cnpq.br/1625450900768652pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4069030512031651pt_BR
dc.description.degreenameTese (Doutorado)pt_BR
dc.description.resumoNeste trabalho foi avaliado o potencial do processo foto-Fenton como etapa complementar ao tratamento de esgoto urbano visando a degradação de ciprofloxacino (CIP) (3,3 mg L–1) e de fipronil (FIP) (1,0 mg L–1). Além disso, este processo foi avaliado como tratamento alternativo para a descontaminação e redução da toxicidade de um efluente agroquímico contendo 403 mg L–1 de ametrina (AMT), 2153 mg L–1 de atrazina (ATZ), 2936 mg L–1 de imidaclopride (IMD) e 3354 mg L–1 de tebuthiuron (TBT). Inicialmente, foi feito um estudo de avaliação dos parâmetros operacionais do processo foto-Fenton modificado para degradação de CIP e FIP em condições próximas às ambientais: pH, fonte e concentração de ferro e, razão molar Fe3+/ligante. Em água destilada, pH 6,0–6,5 foi obtido 90% de degradação de CIP (usando 10 µmol L–1 de FeCit) e 98% de degradação de FIP (usando 32 µmol L–1 de FeCit) na razão molar Fe3+/citrato 1:3. Em efluente de estação de tratamento de esgoto (ETE) e pH 6,0, houve 83% de degradação de FIP. Contudo, foi necessário aumentar a concentração de FeCit em 6 vezes (192 µmol L–1) devido a interferência da matéria orgânica natural e dos íons inorgânicos presentes no efluente de ETE. Foram identificados três produtos de transformação (PT) de CIP e, oito PT de FIP. Os resultados revelaram, que a degradação de CIP e FIP através do processo foto-Fenton ocorreu preferencialmente via ataque HO• no anel piperazina do CIP e anel pirazol do FIP. Para o tratamento de efluente agroquímico, inicialmente foi aplicado os processos de coagulação-floculação-decantação utilizando 8 mmol L-1 de Fe(NO3)3, responsável por 99% de remoção de cor e turbidez. Em seguida, foi aplicado o processo foto-Fenton resultando em efetiva degradação dos pesticidas ([AMT, ATZ, IMD e TBT] ≤ 10 µg L–1 (utilizando 2 mmol L–1 de FeOx e luz solar)). Além disso, houve redução de 79% de DQO e 71% de DBO5. Foi observado que o uso de radiação solar no processo foto-Fenton aumentou a cinética de degradação dos compostos-alvo quando comparado aos experimentos com radiação de luz negra. O monitoramento da toxicidade aguda (mortalidade de moscas D. melanogaster (para FIP) e a inibição da luminescência das bactérias V. fischeri (para o efluente agroquímico)) indicou que o processo foto-Fenton além de ser efetivo na degradação dos contaminantes, também foi eficaz na redução da toxicidade. De forma geral, os resultados mostraram que o processo foto-Fenton foi viável para degradação de CIP e FIP tanto na simulação em água destilada quanto em efluente de ETE e, também para o tratamento de efluente agroquímico.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.programPrograma de Pós-graduação em Químicapt_BR
dc.sizeorduration167pt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::ANALISE DE TRACOS E QUIMICA AMBIENTALpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::TRATAMENTO DE AGUAS DE ABASTECIMENTO E RESIDUARIAS::TECNICAS AVANCADAS DE TRATAMENTO DE AGUASpt_BR
dc.identifier.doihttp://doi.org/10.14393/ufu.te.2021.5533pt_BR
dc.orcid.putcode99437531-
dc.crossref.doibatchid2f7155b6-b3ce-4e53-9482-7f04667bb37c-
dc.subject.autorizadoQuímicapt_BR
Appears in Collections:TESE - Química

Files in This Item:
File Description SizeFormat 
PotencialProcessoFoto-Fenton.pdfTese3.35 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons