Please use this identifier to cite or link to this item: https://repositorio.ufu.br/handle/123456789/28996
Full metadata record
DC FieldValueLanguage
dc.creatorReis, Arnaldo Ferreira-
dc.date.accessioned2020-03-13T20:32:40Z-
dc.date.available2020-03-13T20:32:40Z-
dc.date.issued2019-07-12-
dc.identifier.citationREIS, Arnaldo Ferreira dos. Estudo de fantomas e tecidos biológicos por meio de mapas de absorção e espalhamento ópticos obtidos pela técnica de imagem no domínio da frequência espacial. 2019. 166 f. Tese ( doutorado em Física) - Universidade Federal de Uberlândia, Uberlândia, 2019. DOI http://dx.doi.org/10.14393/ufu.te.2019.2245pt_BR
dc.identifier.urihttps://repositorio.ufu.br/handle/123456789/28996-
dc.description.abstractWhen detected early, skin cancer can have great chances of cure and one of the current forms of diagnosis performed by dermatologist physicians consists of biopsy. Therefore, during this exam, part of the suspicious tissue is collected and then it is sent to a pathological anatomy laboratory, where the observation report will be issued. However, this process is invasive and neglects the evolution of the disease. In order to overcome these problems, this research aims to propose a new methodology to detect skin cancer using the Spatial Frequency Domain Imaging technique (SFDI). In the theoretical part, the present research was based on CUCCIA (2009), TUCHIN (2000), BODENSCHATZ (2015), and others. In relation to the SFDI technique, it consists in an optical method that uses wide field geometry and which is non-invasive and non-contact. In addition, this technique is capable of interrogate skin depths of about 1 to 5 mm and quantifies the concentrations of clinically relevant chromophores such as oxyhemoglobin, deoxyhemoglobin, lipids, water and melanin by spatial maps of the absorption coefficient 𝜇𝛼 and reduced scattering coefficient (𝜇𝑆′ ). Regarding the research methodology, the developed SFDI device consists in a light microprojector which is used for projections of sinusoidal patterns at different spatial frequencies on the sample surface, so that the diffuse reflection that comes is captured using a CCD camera which has six filters for the wave length selection (530, 650, 680, 750, 780 and 810nm). The technique was previously applied in the study of phantoms as optical properties similar to those of the biological tissues for equipment calibration and, subsequentially, in the measures in ex vivo and in vivo. The results obtained by the SFDI were compared to the results obtained from an integrating sphere and were satisfactory for biomedical applications.pt_BR
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal de Uberlândiapt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectCoeficiente de Absorçãopt_BR
dc.subjectCoeficiente de Espalhamentopt_BR
dc.subjectPele humanapt_BR
dc.subjectReflexão difusapt_BR
dc.subjectSFDIpt_BR
dc.subjectAbsorption Coefficientpt_BR
dc.subjectHuman skinpt_BR
dc.subjectDiffuse reflectionpt_BR
dc.subjectReduced Scattering Coefficientpt_BR
dc.subjectSFDIpt_BR
dc.titleEstudo de fantomas e tecidos biológicos por meio de mapas de absorção e espalhamento ópticos obtidos pela técnica de imagem no domínio da frequência espacialpt_BR
dc.title.alternativeStudy of phantoms and biological tissues through optical absorption and scaterring maps obtained by spatial frequency domain imaging techniquept_BR
dc.typeTesept_BR
dc.contributor.advisor-co1Andrade, Acácio Aparecido de Castro-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/4441691798330519pt_BR
dc.contributor.advisor1Monte, Adamo Ferreira Gomes do-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2149564760914561pt_BR
dc.contributor.referee2Serrano, Raimundo Lora-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/8861468720556013pt_BR
dc.contributor.referee3Pilla, Viviane-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/2792016882986736pt_BR
dc.contributor.referee4Marques, Flavio Augusto de Melo-
dc.contributor.referee4Latteshttp://lattes.cnpq.br/5772735542654514pt_BR
dc.contributor.referee5Morais, Paulo Cesar de-
dc.contributor.referee5Latteshttp://lattes.cnpq.br/5847787136001573pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4242531082047161pt_BR
dc.description.degreenameTese (Doutorado)pt_BR
dc.description.resumoQuando detectado precocemente, o câncer de pele pode ter grandes chances de cura e uma das formas de diagnóstico atuais realizadas pelo médico dermatologista consiste na biópsia. Durante a realização deste exame, é coletada parte do tecido suspeito e este é encaminhado para um laboratório de anatomia patológica que emitirá o laudo de observação. Contudo, este processo é invasivo e negligencia a evolução da doença. Para contornar esses problemas, a presente pesquisa tem como objetivo propor uma nova metodologia para detecção do câncer de pele utilizando a técnica de imagem no domínio de frequência espacial (SFDI). Na parte teórica, a pesquisa embasou-se nos trabalhos de CUCCIA (2009), TUCHIN (2000), BODENSCHATZ (2015), entre outros. Em relação à técnica SFDI, esta consiste em um método óptico que utiliza geometria de campo largo e que é não invasivo e sem contato. Além disso, esta técnica é capaz de interrogar profundidades da pele de cerca de 1 a 5 mm e quantifica as concentrações de cromóforos clinicamente relevantes como a oxihemoglobina, deoxihemoglobina, lipídios, água e melanina por meio de mapas espaciais dos coeficientes absorção (𝜇𝛼) e espalhamento reduzido (𝜇𝑆′ ). Em relação à metodologia da presente pesquisa, o dispositivo SFDI desenvolvido consiste em um microprojetor de luz que é utilizado para projeções de padrões senoidais em diferentes frequências espaciais na superfície da amostra, de modo que a reflexão difusa proveniente é capturada usando uma câmera CCD que possui seis filtros para a seleção do comprimento de onda (530, 650, 680, 750, 780 e 810 nm). A técnica foi aplicada previamente no estudo de fantomas com propriedades ópticas semelhantes à de tecidos biológicos para calibração do equipamento e, posteriormente, na realização de medidas em ex vivo e in vivo. Os resultados obtidos por meio do SFDI foram comparados aos resultados obtidos de uma esfera integradora e mostraram-se satisfatórios para aplicações biomédicas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.programPrograma de Pós-graduação em Físicapt_BR
dc.sizeorduration167pt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::FISICApt_BR
dc.identifier.doihttp://dx.doi.org/10.14393/ufu.te.2019.2245pt_BR
dc.crossref.doibatchid89da9dcf-8a13-4319-a675-f62872bc0411-
Appears in Collections:TESE - Física

Files in This Item:
File Description SizeFormat 
EstudoFantomasTecidos.pdf47.18 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.